QuatCy: A Heptamethine Cyanine Modification With Improved Characteristics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A major restriction on optical imaging techniques is the range of available fluorophores that are compatible with aqueous media without aggregation, absorb light above 750 nm with high extinction coefficients, fluoresce with relatively high quantum yields, and resist photodecomposition.Indocyanine green (ICG or A in this paper) is an important example of a fluorophore that fits this description.Other dyes that are becoming increasingly prevalent are select heptamethine cyanine dyes (Cy7) which feature a cyclohexyl framework to rigidify the conjugated alkenes, and meso-chlorine substitution; MHI-148 (B) is one example.Methods: Research described here was initiated to uncover the consequences of a simple isoelectronic substitution to MHI-148 that replaces a cyclohexyl methylene with a dialkyl ammonium fragment.Solubility experiments were carried out in aqueous and cell culture media, photophysical properties including fluorescence quantum yields, brightness and stability were measured.Moreover, in vivo pharmacokinetics, distribution and tumor seeking properties were also explored.Results: Modification to incorporate dialkyl ammonium fragment leads to a brighter, more photostable fluorophore, with a decreased tendency to aggregation, complementary solubility characteristics, and a lower cytotoxicity.Conclusion: All the above-mentioned parameters are favorable for many anticipated applications of the new dye we now call quaternary cyanine-7 or QuatCy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827 · cited 1×
“This fluorophore, variously known as MHI-148 [13] or IR-808 [14], is also exceptional because it accumulates in solid tumors (eg prostate [15], gastric [16], kidney [17]) but not in normal cells and tissue [13, 14, 18-20].”
Background
Cited by
Li, D., Schreiber, C. L., & Smith, B. D. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202004449 · Cited by 163
Medeiros, N. G., Braga, C. A., Câmara, V. S., Duarte, R. C., & Rodembusch, F. S. (2022) · Asian Journal of Organic Chemistry · doi:10.1002/ajoc.202200095 · Cited by 36
Cartilage-targeting fluorophores for early detection of arthritis in the NIR-II window
Kang, H., Park, S. H., Ozmen, G. E., Hur, W., Dinh, J., Wang, H., Nguyen, V., Ahn, S., Yamashita, A., Stiles, W. R., et al. (2025) · Chem · doi:10.1016/j.chempr.2025.102481 · Cited by 17
Self-citationXu, J., Du, Y., Zhu, N., Li, J., Zhang, Y., Zhou, D., & Zhu, S. (2025) · Advanced Science · doi:10.1002/advs.202500443 · Cited by 10
Gao, W., Liu, D., Li, H., He, Z., Liu, Y., Li, X., Ma, H., & Shi, W. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202404996 · Cited by 1
Metadata
- Authors
- Thavornpradit, S., Usama, S. M., Park, G. K., Shrestha, J. P., Nomura, S., Baek, Y., Choi, H. S., & Burgess, K.
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2019
- Volume
- 9
- Issue
- 10
- Pages
- 2856-2867
- ISSN
- 1838-7640 (ISSN-L)
- OpenAlex
- W2938472446
- Cited by
- 86
- References
- 1
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.