Cited by 37Molecular Sensors and Ion DetectionLuminescence and Fluorescent MaterialsPhotochemistry and Electron Transfer Studies

Near‐Infrared Fluorophores Based on Heptamethine Cyanine Dyes: From Their Synthesis and Photophysical Properties to Recent Optical Sensing and Bioimaging Applications

Medeiros, Natália G., Braga, Cláudia A., Câmara, Viktor S., Duarte, Rodrigo C., Rodembusch, Fabiano S.·2022·Asian Journal of Organic Chemistry

Abstract

This review summarizes diverse synthetic methodologies to prepare a wide range of heptamethine cyanine dyes, including symmetrical, unsymmetrical, and meso‐substituted derivatives, and their photophysical properties and uses. Their sensing applications are also discussed, considering the nature of their electronic structures and photophysical properties. The optical sensing applications of these compounds can be potentially expanded via structural modification, broadening their absorption amplitude and spectral emission range from the ultraviolet to near‐infrared (NIR) region. In this review, several recent practical applications of the heptamethine cyanine dyes for ion and small molecule sensing, as well as bioimaging, are covered and discussed.

Integrity signals

Registry

Crossref · 10.1002/ajoc.202200095

Cites

139 of 139 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Significant red-shifts in emission wavelength are primarily achieved through elongation of the polymethine chain and fine structural modifications, including extension or modification of terminal heterocycles, electron-donating or withdrawing substituents on terminal units, and cyclization of the polymethine chain.

    “Significant red-shifts in emission wavelength are primarily achieved through two strategies: elongation of the polymethine chain and fine structural modifications, including extension or modification of terminal heterocycles, electron-donating or withdrawing substituents on terminal units and cyclization of the polymethine chain111–113.”
  • Each methylene unit inserted between donor and acceptor typically induces a red-shift of ~100 nm.

    “A general rule, as exemplified in cyanine dyes, is that each methylene unit inserted between donor and acceptor typically induces a red-shift of ~100 nm111–123.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Medeiros, N. G., Braga, C. A., Câmara, V. S., Duarte, R. C., & Rodembusch, F. S.
Affiliations
  • Universidade Federal do Rio Grande do Sul (BR)
  • Grupo de Pesquisa em Fotoquímica Orgânica Aplicada (GPFOA) Instituto de Química Universidade Federal do Rio Grande do Sul Av. Bento Gonçalves 9500 CEP 91501-970 Porto Alegre-RS Brazil
Corresponding author
Rodembusch, Fabiano S.
Venue
Asian Journal of Organic Chemistry
Publisher
Wiley
Published
2022-04-26
Volume
11
Issue
6
ISSN
  • 2193-5807 (ISSN-L)
  • 2193-5815
OpenAlex
W4221037631
Cited by
36
References
139
Citations by year
2026: 4 · 2025: 9 · 2024: 13 · 2023: 9 · 2022: 1
FWCI
2.89
Type
journal article
Language
en
Open access
closed
Locations
Asian Journal of Organic Chemistry (publishedVersion)
Funders
Conselho Nacional de Desenvolvimento Científico e Tecnológico (409855/2018-9, 305954/2019-9)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Photochemistry and Electron Transfer Studies
Keywords
heptamethine cyanine dyes, near-infrared fluorophores, dye synthesis, photophysical properties, optical sensing, ion detection, small molecule detection, bioimaging, electronic structure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review