Cited by 1Luminescence and Fluorescent MaterialsMolecular Sensors and Ion DetectionOptical Imaging and Spectroscopy Techniques

NIR‐II Cyazulene Fluorophores with Adjustable Cycloalkenes and Spectroscopic Properties for Imaging Applications

Open access
Gao, Wenjie, Liu, Diankai, Li, He, He, Zixu, Liu, Ya, Li, Xiaohua, Ma, Huimin, Shi, Wen·2025·Advanced Healthcare Materials

Abstract

NIR‐II fluorescence imaging has shown broad application prospects in life science because of its deeper tissue penetration and higher spatiotemporal resolution. Developing NIR‐II fluorophores with special spectroscopic properties and analytical functions has become a cutting‐edge but challenging topic in this field. Herein, a series of azulene‐based NIR‐II fluorophores (called cyazulenes) with adjustable cycloalkenes and spectroscopic properties for imaging applications is reported. Cyazulenes (CA965, CA985, and CA1025) are constructed via the convenient coupling of cycloalkenes with azulene derivatives. They exhibit different H‐aggregation and J‐aggregation. Particularly noteworthy is that CA985 can form significant J‐aggregates with strong and sharp NIR‐II emission in biological media, and can be used for in vivo imaging of blood vessels and fine structures of collecting lymphatics in mice. Moreover, CA985 displays passive bone‐targeted capacity, thereby enabling bone imaging. This study demonstrates the chemical impact of varying cycloalkenes on the aggregate formation and spectral properties of cyazulenes, which will advance azulene‐based NIR‐II fluorophores.

Integrity signals

Registry

Crossref · 10.1002/adhm.202404996

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Azulene derivatives exhibited strong absorption within the NIR-II window and strong fluorescence emission from 945 to 1025 nm.

    “All compounds exhibited strong absorption within the NIR-II window and strong fluorescence emission (945–1025 nm).”
  • Shi et al. reported azulene-based NIR-II fluorophores with tunable cycloalkene units and spectroscopic properties.

    “Shi et al. reported a novel series of azulene-based NIR-II fluorophores (Fig. 3a), with tunable cycloalkene units and spectroscopic properties100.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gao, W., Liu, D., Li, H., He, Z., Liu, Y., Li, X., Ma, H., & Shi, W.
Affiliations
Chinese Academy of Sciences (CN)
Corresponding author
  • Ma, Huimin
  • Shi, Wen
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2025-02-16
Volume
14
Issue
10
Pages
e2404996-e2404996
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W4407610620
Cited by
1
References
5
Citations by year
2025: 1
FWCI
0.21
Type
journal article
Language
en
Open access
Locations
  • Advanced Healthcare Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (22474144, 22174147, 22174148, 22374153, 22474147)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
NIR-II fluorescence imaging, cycloalkenes, J-aggregation, H-aggregation, aggregate formation, lymphatic imaging, bone imaging, deep tissue imaging
MeSH terms
Animals, Cycloparaffins, Fluorescent Dyes, Humans, Spectroscopy, Near-Infrared, Mice, Azulenes, Optical Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review