Applications of Magnetic Microbubbles for Theranostics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Compared with other diagnostic methods, ultrasound is proven to be a safe, simple, non-invasive and cost-effective imaging technique, but the resolution is not comparable to that of magnetic resonance imaging (MRI). Contrast-enhanced ultrasound employing microbubbles can gain a better resolution and is now widely used to diagnose a number of diseases in the clinic. For the last decade, microbubbles have been widely used as ultrasound contrast agents, drug delivery systems and nucleic acid transfection tools. However, microbubbles are not fairly stable enough in some conditions and are not well administrated distributed in the circulation system. On the other hand, magnetic nanoparticles, as MRI contrast agents, can non-specifically penetrate into normal tissues because of their relatively small sizes. By taking advantage of these two kinds of agents, the magnetic microbubbles which couple magnetic iron oxides nanoparticles in the microbubble structure have been explored. The stability of microbubbles can be raised by encapsulating magnetic nanoparticles into the bubble shells and with the guidance of magnetic field, magnetic microbubbles can be delivered to regions of interest, and after appropriate ultrasound exposure, the nanoparticles can be released to the desired area while the magnetic microbubbles collapse. In this review, we summarize magnetic microbubbles used in diagnostic and therapeutic fields, and predict the potential applications of magnetic microbubbles in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yang, F., Zhang, M., He, W., Chen, P., Cai, X., Yang, L., Gu, N., & Wu, J. (2011) · Small · doi:10.1002/smll.201002185 · Cited by 51
Self-citation
Cited by
The Smart Drug Delivery System and Its Clinical Potential
Liu, D., Yang, F., Xiong, F., & Gu, N. (2016) · Theranostics · doi:10.7150/thno.14858 · Cited by 1,066
“Dual stimuli-responsive DDSs are most common systems and have been investigated, such as thermo- and pHresponsive systems [69, 70], thermo- and lightresponsive systems [71, 72], redox- and pH-responsive systems [30, 31], ultrasonic and magnetic responsive systems [73-77].”
BackgroundSelf-citationQian, X., Zheng, Y., & Chen, Y. (2016) · Advanced Materials · doi:10.1002/adma.201602012 · Cited by 882
Huang, P., Lin, J., Wang, X., Wang, Z., Zhang, C., He, M., Wang, K., Chen, F., Li, Z., Shen, G., et al. (2012) · Advanced Materials · doi:10.1002/adma.201200650 · Cited by 703
Applications and potential toxicity of magnetic iron oxide nanoparticles
Liu, G., Gao, J., Ai, H., & Chen, X. (2013) · Small · doi:10.1002/smll.201201531 · Cited by 570
Gas‐Generating Nanoplatforms: Material Chemistry, Multifunctionality, and Gas Therapy
Yu, L., Hu, P., & Chen, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801964 · Cited by 360
Metadata
- Authors
- Cai, X., Yang, F., & Gu, N.
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2012
- Volume
- 2
- Issue
- 1
- Pages
- 103-112
- ISSN
- 1838-7640 (ISSN-L)
- OpenAlex
- W2103235310
- Cited by
- 71
- References
- 1
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.