CoChat

Distinguishing Benign from Malignant Euadrenal Masses

Gross, Milton D., Shapiro, Brahm, Bouffard, J. Antonio, Glazer, Gary M., Francis, Isaac R., Wilton, Gary P., Khafagi, Frederick, Sonda, L. Paul · 1988 · Annals of Internal Medicine
Cited by 100

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVE: To determine the efficacy of 131I-6-beta-iodomethylnorcholesterol (NP-59) adrenal scintigraphy in distinguishing benign from malignant euadrenal masses. DESIGN: Case series of patients with incidentally discovered unilateral, euadrenal masses. SETTING: Referral-based nuclear medicine clinics at university and affiliated Veterans Administration medical centers. PATIENTS: Consecutive sample of 119 euadrenal patients with unilateral adrenal masses discovered on computed tomographic (CT) scans for reasons other than suspected adrenal disease. INTERVENTIONS: Adrenal scintiscans done using 1 mCi of NP-59 intravenously, and gamma camera imaging 5 to 7 days later. MEASUREMENTS AND MAIN RESULTS: Mean lesion diameter was 3.3 +/- 1.9 cm (SD) (95% CI: 2.9 to 3.6 cm). In 76 patients, NP-59 uptake lateralized to the abnormal adrenal seen on CT scans (concordant imaging), and in all of these patients, a diagnosis of adenoma was made by needle-aspiration biopsy, adrenalectomy, or extended follow-up with repeat CT scans that were unchanged at 6 months or later. Twenty-six patients had absent or markedly reduced NP-59 uptake in the glands identified as abnormal on CT scans (discordant imaging). These adrenal masses proved to be metastatic malignancies in 19 patients, primary adrenal neoplasms other than adenoma in 4, and adrenal cysts in 3. Bilateral, symmetric accumulation of NP-59 was seen in 17 patients, in whom the adrenal masses were shown to be metastatic malignancies in 2, and adenomas in 6 (the lesions in these cases being 2 cm or less in diameter), and lesions not truly involving the adrenal in the rest (periadrenal metastases in 4 and pseudoadrenal masses in 5). Sensitivity was 76% (26 of 34 patients; CI, 58% to 88%); specificity, 100% (85 of 85 patients; CI, 95% to 100%), and accuracy, 93% (111 of 119 patients: CI, 88% to 98%). CONCLUSIONS: Functional NP-59 scintigraphy can be used to accurately and noninvasively characterize many euadrenal masses; concordance of CT and NP-59 scans can be used to exclude the presence of a malignancy or other space-occupying adrenal lesion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-109-8-613

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 100

Metadata

Authors
Gross, M. D., Shapiro, B., Bouffard, J. A., Glazer, G. M., Francis, I. R., Wilton, G. P., Khafagi, F., & Sonda, L. P.
Venue
Annals of Internal Medicine
Published
1988-10-15
Volume
109
Issue
8
Pages
613-618
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2091126817
Cited by
100
References
5
FWCI
5.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.