Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 249

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cardiovascular and Renal Toxicity of a Nonionic Radiographic Contrast Agent after Cardiac Catheterization: A Prospective Trial

Davidson, Charles J., Hlatky, Mark, Morris, Kenneth G., Pieper, Karen, Skelton, Thomas N., Schwab, Steve J., Bashore, Thomas M.·1989·Annals of Internal Medicine

Abstract

STUDY OBJECTIVE: To determine the incidence of cardiovascular and renal toxicity of a nonionic contrast agent when used for cardiac catheterization, and to assess the value of electrolytes and urinalysis results as predictors of nephropathy induced by a contrast agent. STUDY DESIGN: Nonrandomized trial using a criterion standard and a cohort analytic study with a 48-hour follow-up. SETTING: Referral-based university hospital. PATIENTS: Convenience sample of patients having diagnostic cardiac catheterization. Renal function and clinical status were evaluated at baseline in 1,144 patients; at 24 hours in 1,077 (94%); and at 48 hours in 663 (57%). INTERVENTIONS: After patients received saline for hydration, coronary angiography and left ventriculography were done with iopamidol (average dose, 203 +/- 56 cc). MEASUREMENTS AND MAIN RESULTS: The definite and possible incidence of major acute cardiovascular complications from nonionic contrast media was 0.2% and 0.7%, respectively. The mean serum creatinine level increased 11.5 mumol/L from baseline at 24 hours (P less than 0.0001) and 16.8 mumol/L from baseline at 48 hours (P less than 0.0001). Results in a randomly selected training sample were studied to determine predictors of a rise in serum creatinine of 44.2 mumol/L or more. The baseline serum creatinine level and age were significant predictors of renal injury, but hypertension, diabetes mellitus, congestive heart failure, vascular disease, the volume of contrast agent injected or baseline values of urinary variables did not predict nephrotoxicity. In an independent validation sample, only the baseline serum creatinine level was confirmed as a predictor of nephrotoxicity, whereas age was not. A model that predicted contrast-induced nephropathy by the serum creatinine level showed an exponential increase in the risk for nephrotoxicity if the baseline level was 106.1 mumol/L or higher. CONCLUSIONS: Patients have a small but significant rise in serum creatinine after cardiac catheterization with a nonionic contrast agent. Baseline renal insufficiency is the only confirmed predictor of nonionic contrast-induced nephrotoxicity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-110-2-119

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 249

Metadata

Authors
Davidson, C. J., Hlatky, M., Morris, K. G., Pieper, K., Skelton, T. N., Schwab, S. J., & Bashore, T. M.
Venue
Annals of Internal Medicine
Published
1989-01-15
Volume
110
Issue
2
Pages
119-124
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2027695475
Cited by
249
References
1
FWCI
10.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiovascular and Renal Toxicity of a Nonionic Radiographic Contrast Agent after Cardiac Catheterization: A Prospective Trial. https://app.cochat.ai/papers/10.7326/0003-4819-110-2-119
The paper
Davidson, C. J., Hlatky, M., Morris, K. G., Pieper, K., Skelton, T. N., Schwab, S. J., & Bashore, T. M. (1989). Cardiovascular and Renal Toxicity of a Nonionic Radiographic Contrast Agent after Cardiac Catheterization: A Prospective Trial. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-110-2-119

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.