The DOI matches its Crossref record; 134 of the 134 references it cites were found in a registry or an index.
Use of Ambulatory Electrocardiographic (Holter) Monitoring
Abstract
PURPOSE: To evaluate the clinical efficacy of ambulatory electrocardiographic (ECG) monitoring and to develop guidelines for its use in clinical practice. DATA IDENTIFICATION: Studies reported since January 1978 were identified both through computer searches using Index Medicus and extensive manual searching of bibliographies of identified articles. STUDY SELECTION: Only studies that fulfilled methodologic criteria designed to limit bias were reviewed. DATA EXTRACTION: Information describing population and study results was assessed in four major categories (variability, diagnosis, prognosis, and therapy guidance) for both arrhythmia monitoring and ST-segment analysis. RESULTS OF DATA ANALYSIS: The day-to-day variability of arrhythmia and myocardial ischemia detected by ambulatory ECG monitoring may be considerable in an individual patient. Caution must therefore be used in interpreting serial tests. Ambulatory ECG monitoring with diary correlation permits documentation of cardiac arrhythmias causing symptoms, but the diagnostic yield is low unless symptoms are frequent. Such monitoring can provide information about prognosis in patients after acute myocardial infarction. The amount of prognostic information obtained is modest and is outweighed by other measures. There is insufficient information to make conclusions about such monitoring and prognosis in other conditions. Serial ambulatory ECG monitoring may be used to assess the effect of an antiarrhythmic drug in patients with frequent and reproducible ventricular ectopy. The effect of arrhythmia suppression on survival is uncertain. Because of its low sensitivity and specificity, analysis of ST-segment changes during ambulatory ECG monitoring is inaccurate in establishing or excluding the presence of coronary disease. Although anti-ischemic interventions reduce the frequency and duration of ST-segment changes on monitoring, there are no data on the utility of using reduction or elimination of the changes as the endpoint of therapy. CONCLUSIONS: Ambulatory ECG monitoring can provide diagnostic, prognostic, and therapeutic information in many situations, but similar information often may be better obtained in other ways.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a meta-analysis of seven studies conducted on patients with syncope and/or palpitations of unknown origin, Holter monitoring has been seen to have a sensitivity value of only 22%.82”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [82]
Citations
Cites
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Clinical Epidemiology: A Basic Science for Clinical Medicine.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-825_9 · Cited by 3,497
The Cardiac Arrhythmia Suppression Trial (CAST) Investigators (1989) · New England Journal of Medicine · doi:10.1056/nejm198908103210629 · Cited by 3,289
Risk Stratification and Survival after Myocardial Infarction
The Multicenter Postinfarction Research Group (1983) · New England Journal of Medicine · doi:10.1056/nejm198308113090602 · Cited by 1,599
Bigger, J. T., Fleiss, J. L., Kleiger, R. E., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Approaches to Sudden Death from Coronary Heart Disease
Lown, B., & Wolf, M. A. (1971) · Circulation · doi:10.1161/01.cir.44.1.130 · Cited by 1,258
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Deanfield, J. E., Selwyn, A. P., Chierchia, S. L., Maseri, A., Ribeiro, P., Krikler, S. J., & Morgan, M. K. (1983) · The Lancet · doi:10.1016/s0140-6736(83)92295-x · Cited by 718
Silent Ischemia as a Marker for Early Unfavorable Outcomes in Patients with Unstable Angina
Gottlieb, S. O., Weisfeldt, M. L., Ouyang, P., Mellits, E. D., & Gerstenblith, G. (1986) · New England Journal of Medicine · doi:10.1056/nejm198605083141903 · Cited by 673
Long-Term Follow-up of Asymptomatic Healthy Subjects with Frequent and Complex Ventricular Ectopy
Kennedy, H. L., Whitlock, J. A., Sprague, M. K., Kennedy, L. J., Buckingham, T. A., & Goldberg, R. J. (1985) · New England Journal of Medicine · doi:10.1056/nejm198501243120401 · Cited by 628
Research works printed but not linked: 16
- Sheffield L, 1985, Circulation., 71, 626A
- Hertzeanu H, 1979, Acta Cardiol., 34, 375
- Gendelman H, 1983, N Y State J Med., 83, 1161
- Eagle K, 1983, Yale J Biol Med., 56, 1
- Diamond T, 1983, S Afr Med J., 63, 5
- DiMarco J, 1987, Circulation., 75, III
- 10.1001/jama.1967.03120030092017 · DOI
- Lie K, 1974, Eur J Cardiol., 1, 379
- Lovell R, 1971, Lancet., 2, 1055
- Hugenholtz P, 1978, Management of Ventricular Tachycardia:Role of Mexiletine., 572
- Nicklas J, 1988, Circulation., 78, II27A
- Lichstein E, 1983, Circulation., 67, I
- Tamaki N, 1986, J Nucl Med., 27, 911A
- 1975, Circulation., 52, 11
- 10.1016/S0140-6736(83)92295-X · DOI
- 10.1001/jama.1988.03720070030029 · DOI
Cited by
Sorted by citations
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Guidelines on Management (diagnosis and treatment) of syncope ? update 2004
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janousek, J., et al. (2004) · EP Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 650
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Misdiagnosis of epilepsy: many seizure-like attacks have a cardiovascular cause
Zaidi, A., Clough, P., Cooper, P., Scheepers, B., & Fitzpatrick, A. P. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00700-2 · Cited by 422
Kapoor, W. N. (2000) · New England Journal of Medicine · doi:10.1056/nejm200012213432507 · Cited by 322
Metadata
- Authors
- DiMarco, J. P., & Philbrick, J. T.
- Affiliations
- University of Virginia Medical Center (US)
- Corresponding author
- DiMarco, John P.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1990-07-01
- Volume
- 113
- Issue
- 1
- Pages
- 53-68
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1979276457
- Cited by
- 177
- References
- 134
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 8 · 2023: 4 · 2022: 9 · 2021: 9 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 2 · 2016: 2 · 2014: 6 · 2013: 8 · 2012: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- Holter monitoring, arrhythmia monitoring, myocardial ischemia, ST-segment changes, antiarrhythmic drugs, ventricular ectopy, serial ECG monitoring, anti-ischemic therapy
- MeSH terms
- Arrhythmias, Cardiac, Coronary Disease, Humans, Predictive Value of Tests, Prognosis, Reproducibility of Results, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review