Risk Factors for Infusion-related Phlebitis with Small Peripheral Venous Catheters: A Randomized Controlled Trial
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To identify risk factors for infusion-related phlebitis with peripheral intravenous catheters. DESIGN: A randomized trial of two catheter materials, with consideration of 21 potential risk factors. SETTING: A university hospital. PATIENTS: Hospitalized adults without granulocytopenia who received a peripheral intravenous catheter. INTERVENTIONS: House officers or ward nurses inserted the catheters, and each insertion was randomized to a catheter made of tetrafluoroethylene-hexafluoropropylene (FEP-Teflon) or a novel polyetherurethane without leachable additives (PEU-Vialon). MEASUREMENTS: Research nurses scored insertion sites each day for inflammation and cultured catheters at removal. RESULTS: The Kaplan-Meier risk for phlebitis exceeded 50% by day 4 after catheterization. intravenous antibiotics (relative risk, 2.00), female sex (relative risk, 1.88), prolonged (greater than 48 hours) catheterization (relative risk, 1.79), and catheter material (PEU-Vialon: FEP-Teflon) (relative risk, 0.73) strongly predicted phlebitis in a Cox proportional hazards model (each, P less than 0.003). The best-fit model for severe phlebitis identified the same predictors plus catheter-related infection (relative risk, 6.19), phlebitis with a previous catheter (relative risk, 1.54), and anatomic site (hand: forearm, relative risk, 0.71; wrist:forearm, relative risk, 0.60). The low incidence of local catheter-related infection was comparable with the two catheter materials (5.4% [95% CI, 3.8% to 7.6%] and 6.9% [CI, 4.9% to 9.6%]); none of the 1054 catheters prospectively studied caused bacteremia. CONCLUSIONS: Multiple factors, including the infusate and the duration of cannulation, contribute to the development of infusion-related phlebitis. The use of peripheral intravenous catheters made of PEU-Vialon appears to pose the same risk for catheter-related infection as the use of catheters made of FEP-Teflon, and PEU-Vialon can permit longer cannulation with less risk for phlebitis. The risk for catheter-related bacteremia with FEP-Teflon and PEU-Vialon catheters is sufficiently low that it no longer seems justifiable to recommend the use of small steel needles for most peripheral intravenous therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods in Cancer Research. Volume II – The Design and Analysis of Cohort Studies
Juul, S. (1989) · Scandinavian Journal of Social Medicine · doi:10.1177/140349488901700214 · Cited by 3,592
Statistical Methods for Survival Data Analysis.
Lachenbruch, P. A., & Lee, E. T. (1993) · Journal of the American Statistical Association · doi:10.2307/2290742 · Cited by 2,845
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Self-citationInfection Control in Intravenous Therapy
MAKI, D. G., GOLDMNAN, D. A., & RHAME, F. S. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-867 · Cited by 536
Self-citationMaki, D. G., & Band, J. D. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90605-7 · Cited by 226
Self-citationMaki, D. G. (1987) · JAMA · doi:10.1001/jama.1987.03400170082027 · Cited by 192
Self-citationAN EPIDEMIOLOGIC STUDY OF THE RISKS ASSOCIATED WITH PERIPHERAL INTRAVENOUS CATHETERS
THE RHODE ISLAND NOSOCOMIAL INFECTION CONSORTIUM, TAGER, I. B., GINSBERG, M. B., ELLIS, S. E., WALSH, N. E., DUPONT, I., SIMCHEN, E., & FAICH, G. A. (1983) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a113702 · Cited by 189
Maki, D. G. (1987) · JAMA · doi:10.1001/jama.258.13.1777 · Cited by 181
Self-citationTomford, J. W. (1984) · Archives of Internal Medicine · doi:10.1001/archinte.1984.00350180111017 · Cited by 178
Sheth, N. K., Franson, T. R., Rose, H. D., Buckmire, F. L., Cooper, J. A., & Sohnle, P. G. (1983) · Journal of Clinical Microbiology · doi:10.1128/jcm.18.5.1061-1063.1983 · Cited by 161
Complications of intravenous therapy with steel needles and Teflon® catheters
Tully, J. L., FRIEDLAND, G. H., Baldini, L. M., & Goldmann, D. A. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90600-8 · Cited by 142
Zinner, S. H., Denny-Brown, B. C., Braun, P., Burke, J., Toala, P., & Kass, E. H. (1969) · The Journal of Infectious Diseases · doi:10.1093/infdis/120.5.616 · Cited by 131
INFUSION THROMBOPHLEBITIS AND INFECTION WITH VARIOUS CANNULAS
Collin, J., Constable, F. L., Collin, C., & Johnston, I. D. A. (1975) · The Lancet · doi:10.1016/s0140-6736(75)90057-4 · Cited by 121
Lewis, G. B. H., & Hecker, J. F. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.2.220 · Cited by 102
Gaukroger, P. B., Roberts, J. G., & Manners, T. A. (1988) · Anaesthesia and Intensive Care · doi:10.1177/0310057x8801600305 · Cited by 98
The Natural History of Intravenous Catheter—Associated Phlebitis
Hershey, C. O. (1984) · Archives of Internal Medicine · doi:10.1001/archinte.1984.00350190057010 · Cited by 96
The Relationship Between Intravenous Fluid Contamination and the Frequency of Tubing Replacement
Josephson, A., Gombert, M. E., Sierra, M. F., Karanfil, L. V., & Tansino, G. F. (1985) · Infection Control · doi:10.1017/s0195941700063335 · Cited by 89
Khawaja, H. T., Campbell, M. J., & Weaver, P. (1988) · British journal of surgery · doi:10.1002/bjs.1800751223 · Cited by 74
TISSUE NECROSIS CAUSED BY COMMONLY USED INTRAVENOUS INFUSIONS
Gaze, N. R. (1978) · The Lancet · doi:10.1016/s0140-6736(78)91879-2 · Cited by 68
The Natural History of Teflon Catheter–Associated Phlebitis in Children
Nelson, D. B., & Garland, J. S. (1987) · American journal of diseases of children · doi:10.1001/archpedi.1987.04460100068028 · Cited by 60
Hoffmann, K. K., Western, S. A., Kaiser, D. L., Wenzel, R. P., & Gröschel, D. (1988) · American Journal of Infection Control · doi:10.1016/0196-6553(88)90046-6 · Cited by 37
Effects of dressing type and change interval on intravenous therapy complication rates
Gantz, N. M., Presswood, G. M., Goldberg, R. J., & Doern, G. V. (1984) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/0732-8893(84)90064-6 · Cited by 35
In-line filtration and infusion phlebitis.
Sd, A., Killien, M., & Larson, E. B. (1986) · PubMed · Cited by 16
BACTERIAL ADHERENCE TO PLASTICS
Ashkenazi, S. (1984) · The Lancet · doi:10.1016/s0140-6736(84)91481-8 · Cited by 13
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“Phlebitis involving short-term, peripheral intravenous catheters is often unrelated to catheter-related infection [60, 61].”
BackgroundMaki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Self-citationGuidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“There is no need to replace peripheral catheters more frequently than every 72-96 hours to reduce risk of infection and phlebitis in adults [36, 140, 141].”
InfluentialGuidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
Self-citation
Metadata
- Authors
- Maki, D. G., & Ringer, M.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1991-05-15
- Volume
- 114
- Issue
- 10
- Pages
- 845-854
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2075901402
- Cited by
- 497
- References
- 25
- FWCI
- 13.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.