Urine Free Cortisol in the High-Dose Dexamethasone Suppression Test for the Differential Diagnosis of the Cushing Syndrome

Flack, Mary R., Oldfield, Edward H., Cutler, Gordon B., Zweig, Mark H., Malley, James D., Chrousos, George P., Loriaux, D. Lynn, Nieman, Lynnette K. · 1992 · Annals of Internal Medicine

Abstract

OBJECTIVE: To develop criteria for interpreting the high-dose dexamethasone suppression test using urine free cortisol as an end point for the differential diagnosis of the Cushing syndrome. DESIGN: Retrospective review. SETTING: Inpatient research ward. PATIENTS: Patients (118) with surgically confirmed causes of the Cushing syndrome: 94 with pituitary disease, 14 with primary adrenal disease, and 10 with ectopic adrenocorticotropic hormone (ACTH) secretion. MAIN OUTCOME MEASURES: The sensitivity, specificity, and diagnostic accuracy were determined for the high-dose dexamethasone suppression test using urine free cortisol and using 17-hydroxysteroid excretion. For each analysis, patients with pituitary disease were considered to be "diseased" and patients with nonpituitary disease were considered to be "non-diseased". The level of suppression that gave 100% specificity was determined for each steroid. RESULTS: The accuracy of urine free cortisol when used as an end point in the high-dose dexamethasone suppression test was equivalent to that of 17-hydroxysteroid excretion. At all levels of sensitivity and specificity, however, the degree of suppression of urine free cortisol used for the diagnosis of pituitary disease was greater than that of 17-hydroxysteroid excretion. The likelihood ratios for pituitary disease based on urine free cortisol suppression of greater than 50%, of greater than 80%, and of greater than 90% were 4.2, 10.1, and "infinite," respectively. Suppression of urine free cortisol greater than 90% or suppression of 17-hydroxysteroid excretion greater than 64% was associated with 100% specificity. When these criteria were combined, the percentage of correct predictions (102 of 118 [86%; 95% CI, 78% to 92%]) was higher than that obtained using either steroid alone (89 of 118 [75%; CI, 65% to 83%]) (P = 0.009) and higher than that obtained using the traditional criterion of 50% suppression for 17-hydroxysteroid excretion (95 of 118 [80%; CI, 71% to 87%]) (P = 0.016). CONCLUSIONS: In the high-dose dexamethasone suppression test, the degree of suppression of urine free cortisol used for the diagnosis of pituitary disease is greater than that traditionally used for 17-hydroxysteroid excretion. The diagnostic performance of the test is improved by measuring both urine free cortisol and 17-hydroxysteroid excretion and by requiring greater suppression of both steroids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-116-3-211

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Flack, M. R., Oldfield, E. H., Cutler, G. B., Zweig, M. H., Malley, J. D., Chrousos, G. P., Loriaux, D. L., & Nieman, L. K.
Venue
Annals of Internal Medicine
Published
1992-02-01
Volume
116
Issue
3
Pages
211-217
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2080559503
Cited by
165
References
1
FWCI
7.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Urine Free Cortisol in the High-Dose Dexamethasone Suppression Test for the Differential Diagnosis of the Cushing Syndrome. https://app.cochat.ai/papers/10.7326/0003-4819-116-3-211
The paper
Flack, M. R., Oldfield, E. H., Cutler, G. B., Zweig, M. H., Malley, J. D., Chrousos, G. P., Loriaux, D. L., & Nieman, L. K. (1992). Urine Free Cortisol in the High-Dose Dexamethasone Suppression Test for the Differential Diagnosis of the Cushing Syndrome. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-116-3-211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.