Hospital-acquired Infection with Vancomycin-resistant Enterococcus faecium Transmitted by Electronic Thermometers

Livornese, Lawrence L., Dias, Susan, Samel, Carol, Romanowski, Barbara, Taylor, Shirley, May, Phyllis, Pitsakis, Peter, Woods, Gail, Kaye, Donald, Levison, Matthew E., Johnson, Caroline C. · 1992 · Annals of Internal Medicine
Cited by 481

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To describe an epidemic of vancomycin-resistant Enterococcus faecium causing bacteremia and bacteriuria, to identify the source of infection, to delineate risk factors associated with acquisition of the organism, and to determine antibiotic sensitivities for the organism. DESIGN: Investigation of an epidemic, including a case-control study. SETTING: Medical-surgical intensive care unit and ward in a university medical center. PATIENTS: Nine patients infected or colonized with vancomycin-resistant Enterococcus faecium and 20 noninfected controls. MEASUREMENTS: Clinical data, environmental surveillance cultures, and in-vitro microbiologic studies. RESULTS: Colonization or infection by vancomycin-resistant E. faecium was associated with an increased duration of treatment with ceftazidime, 13.2 compared with 4.6 days, and a greater number of nonisolated days of hospitalization in the intensive care unit, 19.9 compared with 6.4 days for infected and noninfected patients, respectively (P less than 0.05). Environmental surveillance cultures recovered the organism repeatedly from the rectal probe handles of three electronic thermometers used exclusively on nonisolated patients in the intensive care unit. Restriction endonuclease analysis of plasmid DNA showed that all clinical and environmental isolates were identical. Infection control measures, including isolation of colonized or infected patients and removal of the rectal thermometer probes suspected to be responsible for transmission, resulted in termination of the outbreak. In-vitro, time-kill studies showed that the combination of ciprofloxacin, rifampin, and gentamicin resulted in bactericidal activity against the organism. CONCLUSIONS: This nosocomial outbreak of infection due to a highly vancomycin-resistant strain of Enterococcus is the first epidemic in which an electronic thermometer has been implicated as the vehicle of transmission for an infectious agent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-117-2-112

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 481

Metadata

Authors
Livornese, L. L., Dias, S., Samel, C., Romanowski, B., Taylor, S., May, P., Pitsakis, P., Woods, G., Kaye, D., Levison, M. E., & Johnson, C. C.
Venue
Annals of Internal Medicine
Published
1992-07-15
Volume
117
Issue
2
Pages
112-116
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2102876406
Cited by
481
References
16
FWCI
25.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.