Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine whether diabetic patients, when compared with nondiabetic patients, have a higher incidence of restenosis after coronary stenting, and, if so, whether restenosis is attributable to lesion or procedural differences or to a greater biologic tendency for late loss of minimum diameter in diabetic patients. DESIGN: Case series. SETTING: Tertiary care referral center. PATIENTS: Two hundred twenty consecutive patients with coronary artery disease who were referred for placement of a Palmaz-Schatz stent in either a native coronary artery or a saphenous vein graft. RESULTS: Based on a traditional dichotomous definition of restenosis (> or = 50% stenosis at follow-up), lesions in diabetic patients had a significantly greater restenosis rate (55%) than lesions in nondiabetic patients (20%; P = 0.001). Vessel size, lesion length, pre-procedure lesion severity, procedural outcome, and acute gain (the difference between minimum lumen diameter before and after the procedure) were similar in the diabetic and nondiabetic groups. However, at follow-up, stents in diabetic patients had a smaller lumen diameter (1.66 +/- 1.18 mm) compared with those in nondiabetic patients (2.24 +/- 0.93 mm; P = 0.004), as well as a greater percent stenosis (49% compared with 32%; P = 0.002). Thus, the increased restenosis rate in stents in diabetic patients (55% compared with 20%; P = 0.001) is secondary to increased late loss of minimum lumen diameter (1.66 +/- 1.28 mm compared with 1.23 +/- 0.97 mm; P = 0.04). CONCLUSIONS: After arterial injury produced by stent placement, diabetic patients have a significantly greater incidence of restenosis because of greater late loss at the treatment site. Because elastic recoil or vasospasm contributes little to stent restenosis, the increased late loss of minimum lumen diameter in diabetic patients suggests that they have a greater predisposition to intimal hyperplasia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetes and Atherosclerosis: Epidemiology, Pathophysiology, and Management
Beckman, J. A., Creager, M. A., & Libby, P. (2002) · JAMA · doi:10.1001/jama.287.19.2570 · Cited by 2,724
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Predictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
Investigators, T. B. (1997) · Circulation · doi:10.1161/01.cir.96.6.1761 · Cited by 619
Stein, B., Weintraub, W. S., Gebhart, S. S. P., Cohen-Bernstein, C. L., Grosswald, R., Liberman, H. A., Douglas, J. S., Morris, D. C., & King, S. B. (1995) · Circulation · doi:10.1161/01.cir.91.4.979 · Cited by 531
Metadata
- Authors
- Carrozza, J. P., Kuntz, R. E., Fishman, R. F., & Baim, D. S.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1993-03-01
- Volume
- 118
- Issue
- 5
- Pages
- 344-349
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1969602771
- Cited by
- 275
- References
- 0
- FWCI
- 10.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus. https://app.cochat.ai/papers/10.7326/0003-4819-118-5-199303010-00004
- The paper
- Carrozza, J. P., Kuntz, R. E., Fishman, R. F., & Baim, D. S. (1993). Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-118-5-199303010-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.