Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine whether diabetic patients, when compared with nondiabetic patients, have a higher incidence of restenosis after coronary stenting, and, if so, whether restenosis is attributable to lesion or procedural differences or to a greater biologic tendency for late loss of minimum diameter in diabetic patients. DESIGN: Case series. SETTING: Tertiary care referral center. PATIENTS: Two hundred twenty consecutive patients with coronary artery disease who were referred for placement of a Palmaz-Schatz stent in either a native coronary artery or a saphenous vein graft. RESULTS: Based on a traditional dichotomous definition of restenosis (> or = 50% stenosis at follow-up), lesions in diabetic patients had a significantly greater restenosis rate (55%) than lesions in nondiabetic patients (20%; P = 0.001). Vessel size, lesion length, pre-procedure lesion severity, procedural outcome, and acute gain (the difference between minimum lumen diameter before and after the procedure) were similar in the diabetic and nondiabetic groups. However, at follow-up, stents in diabetic patients had a smaller lumen diameter (1.66 +/- 1.18 mm) compared with those in nondiabetic patients (2.24 +/- 0.93 mm; P = 0.004), as well as a greater percent stenosis (49% compared with 32%; P = 0.002). Thus, the increased restenosis rate in stents in diabetic patients (55% compared with 20%; P = 0.001) is secondary to increased late loss of minimum lumen diameter (1.66 +/- 1.28 mm compared with 1.23 +/- 0.97 mm; P = 0.04). CONCLUSIONS: After arterial injury produced by stent placement, diabetic patients have a significantly greater incidence of restenosis because of greater late loss at the treatment site. Because elastic recoil or vasospasm contributes little to stent restenosis, the increased late loss of minimum lumen diameter in diabetic patients suggests that they have a greater predisposition to intimal hyperplasia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetes and Atherosclerosis: Epidemiology, Pathophysiology, and Management
Beckman, J. A., Creager, M. A., & Libby, P. (2002) · JAMA · doi:10.1001/jama.287.19.2570 · Cited by 2,724
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Predictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
Investigators, T. B. (1997) · Circulation · doi:10.1161/01.cir.96.6.1761 · Cited by 619
Stein, B., Weintraub, W. S., Gebhart, S. S. P., Cohen-Bernstein, C. L., Grosswald, R., Liberman, H. A., Douglas, J. S., Morris, D. C., & King, S. B. (1995) · Circulation · doi:10.1161/01.cir.91.4.979 · Cited by 531
Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
Elezi, S., Kastrati, A., Pache, J., Wehinger, A., Hadamitzky, M., Dirschinger, J., Neumann, F.-J., & Schömig, A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00467-7 · Cited by 495
Diabetes Mellitus Enhances Vascular Matrix Metalloproteinase Activity: Role of Oxidative Stress
Uemura, S., Matsushita, H., Li, W., Glassford, A. J., Asagami, T., Lee, K.-H., Harrison, D. G., & Tsao, P. S. (2001) · Circulation Research · doi:10.1161/hh1201.092042 · Cited by 485
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1875 · Cited by 484
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
Kornowski, R., Mintz, G. S., Kent, K. M., Pichard, A. D., Satler, L. F., Bucher, T. A., Hong, M. K., Popma, J. J., & Leon, M. B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1366 · Cited by 451
Pathobiology of intimal hyperplasia
Davies, M. G., & Hagen, P.-O. (1994) · Journal of British Surgery · doi:10.1002/bjs.1800810904 · Cited by 413
Moussa, I., Leon, M. B., Baim, D. S., O’Neill, W. W., Popma, J. J., Buchbinder, M., Midwall, J., Simonton, C. A., Keim, E., Wang, P., et al. (2004) · Circulation · doi:10.1161/01.cir.0000129767.45513.71 · Cited by 397
Self-citationAbizaid, A., Costa, M. A., Centemero, M., Abizaid, A. S., Legrand, V. M. G., Limet, R. V., Schuler, G., Mohr, F. W., Lindeboom, W., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/hc3101.093700 · Cited by 337
Calabro, P., Samudio, I., Willerson, J. T., & Yeh, E. T. H. (2004) · Circulation · doi:10.1161/01.cir.0000147825.97879.e7 · Cited by 331
Potential mechanisms promoting restenosis in diabetic patients
Aronson, D., Bloomgarden, Z., & Rayfield, E. J. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00496-3 · Cited by 327
Restenosis after coronary placement of various stent types
Kastrati, A., Mehilli, J., Dirschinger, J., Pache, J., Ulm, K., Schühlen, H., Seyfarth, M., Schmitt, C., Blasini, R., Neumann, F.-J., et al. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01268-6 · Cited by 324
Kastrati, A., Dibra, A., Mehilli, J., Mayer, S., Pinieck, S., Pache, J., Dirschinger, J., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.601823 · Cited by 312
Relationship Between Diabetes Mellitus and Long-term Survival After Coronary Bypass and Angioplasty
Barsness, G. W., Peterson, E. D., Ohman, E. M., Nelson, C. L., DeLong, E. R., Reves, J. G., Smith, P. K., Anderson, R. D., Jones, R. H., Mark, D. B., et al. (1997) · Circulation · doi:10.1161/01.cir.96.8.2551 · Cited by 290
Marso, S. P., Lincoff, A. M., Ellis, S. G., Bhatt, D. L., Tanguay, J.-F., Kleiman, N. S., Hammoud, T., Booth, J. E., Sapp, S. K., & Topol, E. J. (1999) · Circulation · doi:10.1161/01.cir.100.25.2477 · Cited by 288
Vascular dysfunction in diabetes mellitus
Feener, E. P., & King, G. L. (1997) · The Lancet · doi:10.1016/s0140-6736(97)90022-2 · Cited by 287
Predictors of Restenosis After Coronary Stent Implantation
Bauters, C., Hubert, E., Prat, A., Bougrimi, K., Van Belle, E., McFadden, E. P., Amouyel, P., Lablanche, J.-M., & Bertrand, M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00076-x · Cited by 275
Van Belle, E., Bauters, C., Hubert, E., Bodart, J.-C., Abolmaali, K., Meurice, T., McFadden, E. P., Lablanche, J.-M., & Bertrand, M. E. (1997) · Circulation · doi:10.1161/01.cir.96.5.1454 · Cited by 270
Defining coronary restenosis. Newer clinical and angiographic paradigms.
Kuntz, R. E., & Baim, D. S. (1993) · Circulation · doi:10.1161/01.cir.88.3.1310 · Cited by 263
Self-citationOutcomes with the polymer-based paclitaxel-eluting TAXUS stent in patients with diabetes mellitus
Hermiller, J. B., Raizner, A., Cannon, L., Gurbel, P. A., Kutcher, M. A., Wong, S. C., Russell, M. E., Ellis, S. G., Mehran, R., & Stone, G. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.075 · Cited by 247
Choi, D., Kim, S.-K., Choi, S.-H., Ko, Y.-G., Ahn, C.-W., Jang, Y., Lim, S.-K., Lee, H.-C., & Cha, B.-S. (2004) · Diabetes Care · doi:10.2337/diacare.27.11.2654 · Cited by 243
“Although a coronary stent implant is recognized to be a useful treatment for CAD (2), in-stent restenosis is still a significant clinical problem (3), and the restenosis rates in nondiabetic patients who receive stent implants are still 20–40% after 6 months (4–6).”
BackgroundInfluentialAbizaid, A. S., Mintz, G. S., Mehran, R., Abizaid, A., Lansky, A. J., Pichard, A. D., Satler, L. F., Wu, H., Pappas, C., Kent, K. M., et al. (1999) · Circulation · doi:10.1161/01.cir.100.3.256 · Cited by 225
Corpus, R. A., George, P. B., House, J. A., Dixon, S. R., Ajluni, S. C., Devlin, W. H., Timmis, G. C., Balasubramaniam, M., & O'Neill, W. W. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.06.019 · Cited by 218
Platelet glycoprotein IIb/IIIa receptor blockade in coronary artery disease
Lincoff, A. M., Califf, R. M., & Topol, E. J. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00554-4 · Cited by 197
“narrowing, abciximab may reduce restenosis, particularly among diabetic patients, who are known to be at elevated risk for this late complication (38).”
BackgroundTakagi, T., Akasaka, T., Yamamuro, A., Honda, Y., Hozumi, T., Morioka, S., & Yoshida, K. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00895-0 · Cited by 187
Ribichini, F., Steffenino, G., Dellavalle, A., Matullo, G., Colajanni, E., Camilla, T., Vado, A., Benetton, G., Uslenghi, E., & Piazza, A. (1998) · Circulation · doi:10.1161/01.cir.97.2.147 · Cited by 177
Nanoparticle drug delivery system for restenosis
Labhasetwar, V., Song, C., & Levy, R. J. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00483-8 · Cited by 169
Metadata
- Authors
- Carrozza, J. P., Kuntz, R. E., Fishman, R. F., & Baim, D. S.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1993-03-01
- Volume
- 118
- Issue
- 5
- Pages
- 344-349
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1969602771
- Cited by
- 275
- References
- 0
- FWCI
- 10.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.