Accuracy of Ultrasound for the Diagnosis of Deep Venous Thrombosis in Asymptomatic Patients after Orthopedic Surgery: A Meta-Analysis
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate, by meta-analysis, the accuracy of ultrasound screening for deep venous thrombosis in patients after orthopedic surgery. DATA SOURCES: The MEDLINE database from January 1982 to October 1993. Bibliographies of retrieved articles and recent journal publications were searched independently and using Current Contents. STUDY SELECTION: All articles evaluating the use of venous ultrasound imaging (B-mode, duplex, and color Doppler) compared with standard contrast venography for detecting deep venous thrombosis. We excluded abstracts, early reports of studies later reported in full, and studies in which venography was not done in all patients. Seventeen of 30 identified studies were eligible. DATA EXTRACTION: Eligible articles were reviewed for the presence of three key criteria necessary for evaluating the accuracy of the diagnostic tests: 1) previously established objective criteria for venography and ultrasound, 2) independent blinded comparisons of venography and ultrasound, and 3) prospective evaluations of consecutive patients. Studies including all three key criteria were defined as level 1 (minimized bias) studies; otherwise, they were defined as level 2 studies. DATA SYNTHESIS: In level 1 studies, ultrasonography had a sensitivity of 62% (95 of 153; 95% CI, 54% to 70%), a specificity of 97% (CI, 96% to 98%), and a positive predictive value of 66% (95 of 144; CI, 58% to 74%) for detecting proximal thrombi. For level 2 studies, the sensitivity was 95% (CI, 87% to 99%), the specificity was 100% (CI, 99% to 100%), and the positive predictive value was 100% (CI, 94% to 100%). Differences between level 1 and level 2 studies appeared to be related to bias in study design. CONCLUSIONS: Venous ultrasound imaging has only moderate sensitivity and a moderate positive predictive value when used to screen for deep venous thrombosis in patients after orthopedic surgery; thus, ultrasound imaging may have limitations as a screening test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Pineo, G. F., Heit, J. A., Bergqvist, D., Lassen, M. R., Colwell, C. W., & Ray, J. G. (2004) · Chest · doi:10.1378/chest.126.3_suppl.338s · Cited by 5,895
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Samama, M. M., Cohen, A. T., Darmon, J.-Y., Desjardins, L., Eldor, A., Janbon, C., Leizorovicz, A., Nguyen, H., Olsson, C.-G., Turpie, A. G., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909093411103 · Cited by 1,584
Geerts, W. H., Jay, R. M., Code, K. I., Chen, E., Szalai, J. P., Saibil, E. A., & Hamilton, P. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609053351003 · Cited by 808
Accuracy of clinical assessment of deep-vein thrombosis
Wells, P., Hirsh, J., Anderson, D., Lensing, A. A., Foster, G., Kearon, C., Weitz, J., D'Ovidio, R., Cogo, A., Prandoni, P., et al. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92535-x · Cited by 798
Self-citationNon-invasive diagnosis of venous thromboembolism in outpatients
Perrier, A., Desmarais, S., Miron, M.-J., de Moerloose, P., Lepage, R., Slosman, D., Didier, D., Unger, P.-F., Patenaude, J.-V., & Bounameaux, H. (1999) · The Lancet · doi:10.1016/s0140-6736(98)05248-9 · Cited by 791
Rogers, F. B., Cipolle, M. D., Velmahos, G., Rozycki, G., & Luchette, F. A. (2002) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200207000-00032 · Cited by 713
Noninvasive Diagnosis of Deep Venous Thrombosis
Kearon, C., Julian, J. A., Math, M., Newman, T. E., & Ginsberg, J. S. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-8-199804150-00011 · Cited by 690
Guidelines on diagnosis and management of acute pulmonary embolism
(2000) · European Heart Journal · doi:10.1053/euhj.2000.2250 · Cited by 645
Hirsh, J., & Hoak, J. (1996) · Circulation · doi:10.1161/01.cir.93.12.2212 · Cited by 635
Self-citationKearon, C., Ginsberg, J. S., & Hirsh, J. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-12-199812150-00009 · Cited by 489
Self-citationAsymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy
Song, F., Khan, K. S., Dinnes, J., & Sutton, A. J. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.88 · Cited by 484
Bergqvist, D., Benoni, G., Björgell, O., Fredin, H., Hedlundh, U., Nicolas, S., Nilsson, P., & Nylander, G. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609053351002 · Cited by 457
Planes, A., Vochelle, N., Darmon, J.-Y., Fagola, M., Bellaud, M., & Huet, Y. (1996) · The Lancet · doi:10.1016/s0140-6736(96)01453-5 · Cited by 432
Goldhaber, S. Z. (1998) · New England Journal of Medicine · doi:10.1056/nejm199807093390207 · Cited by 428
Prevention of Venous Thromboembolism
Clagett, G. P., Anderson, F. A., Geerts, W., Heit, J. A., Knudson, M., Lieberman, J. R., Merli, G. J., & Wheeler, H. B. (1998) · Chest · doi:10.1378/chest.114.5_supplement.531s · Cited by 378
Prevention of Venous Thromboembolism
Clagett, G. P., Anderson, F. A., Heit, J., Levine, M. N., & Wheeler, H. B. (1995) · Chest · doi:10.1378/chest.108.4_supplement.312s · Cited by 364
The Diagnostic Approach to Acute Venous Thromboembolism: Clinical Practice Guideline
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.3.16030 · Cited by 325
Turkstra, F., Kuijer, P. M. M., van Beek, E. J. R., Brandjes, D. P. M., ten Cate, J. W., & Buller, H. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-10-199705150-00005 · Cited by 298
(1997) · British Journal of Surgery · doi:10.1046/j.1365-2168.1997.d01-3882.x · Cited by 296
Venous Thromboembolism After Acute Stroke
Kelly, J., Rudd, A., Lewis, R., & Hunt, B. J. (2001) · Stroke · doi:10.1161/01.str.32.1.262 · Cited by 270
Hull, R. D. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.14.2199 · Cited by 262
Spiral Computed Tomography for Acute Pulmonary Embolism
Schoepf, U. J., Goldhaber, S. Z., & Costello, P. (2004) · Circulation · doi:10.1161/01.cir.0000128813.04325.08 · Cited by 237
Righini, M., Sanchez, O., Roy, P.-M., Baba-Ahmed, M., Perrier, A., Bounameaux, H., & Le Gal, G. (2006) · Thrombosis and Haemostasis · doi:10.1160/th06-03-0158 · Cited by 236
“However, the diagnostic accuracy of this test is dramatically reduced in patients without leg symptoms (3, 4), which is often the case in patients suspected of PE.”
BackgroundDeep Venous Thrombosis: Recent Advances and Optimal Investigation with US
Fraser, J. D., & Anderson, D. R. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap459 · Cited by 217
Hull, R. D. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.14.2208 · Cited by 210
Diagnosis and treatment of deep-vein thrombosis
Scarvelis, D., & Wells, P. S. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.060366 · Cited by 205
Self-citationLassen, M. R., Borris, L. C., & Nakov, R. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011327 · Cited by 201
WARWICK, D., HARRISON, J., GLEW, D., MITCHELMORE, A., PETERS, T. J., & DONOVAN, J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199808000-00009 · Cited by 197
Integrated strategies for the diagnosis of venous thromboembolism
WELLS, P. S. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02493.x · Cited by 190
Self-citationPsychological testing and psychological assessment: A review of evidence and issues.
Meyer, G. J., Finn, S. E., Eyde, L. D., Kay, G. G., Moreland, K. L., Dies, R. R., Eisman, E. J., Kubiszyn, T. W., & Reed, G. M. (2001) · American Psychologist · doi:10.1037//0003-066x.56.2.128 · Cited by 1,469
Steele, K. E., Canner, J., Prokopowicz, G., Verde, F., Beselman, A., Wyse, R., Chen, J., Streiff, M., Magnuson, T., Lidor, A., et al. (2015) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2014.10.003 · Cited by 54
“Various investigators have attempted to use duplex ultrasound in place of venography, but the sensitivity of duplex ultrasound in the general population is poor (38 to 62%) [29,30], and is likely worse in the morbidly obese due to large lower extremities and the pannus that may overlie the inguinal region and obscure…”
Background
Metadata
- Authors
- Wells, P. S., Lensing, A. W. A., Davidson, B. L., Prins, M. H., & Hirsh, J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1995-01-01
- Volume
- 122
- Issue
- 1
- Pages
- 47-53
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2078035232
- Cited by
- 327
- References
- 0
- FWCI
- 17.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.