Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record.

Mechanical Ventilation with or without 7-Day Circuit Changes: A Randomized Controlled Trial

Kollef, Marin H., Shapiro, Steven D., Fraser, Victoria J., Silver, Patricia, Murphy, Denise M., Trovillion, Ellen, Hearns, Mona L., Richards, Rodger D., Cracchilo, Lisa, Hossin, Linda · 1995 · Annals of Internal Medicine

Abstract

OBJECTIVE: To determine whether a practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with an increased incidence of nosocomial pneumonia. DESIGN: Randomized controlled trial. SETTING: Intensive care units in two university-affiliated teaching hospitals. PATIENTS: 300 patients admitted to an intensive care unit who required mechanical ventilation for more than 5 days. INTERVENTION: Patients were randomly assigned to receive either no routine ventilator circuit changes or circuit changes every 7 days. MEASUREMENTS: The primary outcome measure was the incidence of ventilator-associated pneumonia. Other outcome measures included duration of mechanical ventilation, length of hospital stay, and hospital mortality. RESULTS: 147 patients were randomly assigned to receive no routine ventilator circuit changes, and 153 patients were randomly assigned to receive circuit changes every 7 days. The two groups were similar at the time of randomization with regard to demographic characteristics, intensive care unit admission diagnoses, and severity of illness. Ventilator-associated pneumonia was seen in 36 patients (24.5%) receiving no routine changes and in 44 patients (28.8%) receiving changes every 7 days (relative risk, 0.85 [95% CI, 0.55 to 1.17]). No statistically significant differences for hospital mortality, intensive care unit mortality, death during mechanical ventilation, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups (P > or = 0.11). Patients receiving changes every 7 days had 247 circuit changes costing a total of $7410; patients receiving no routine changes had a total of 11 circuit changes costing $330. CONCLUSION: The elimination of routine ventilator circuit changes can reduce medical care costs without increasing the incidence of nosocomial pneumonia in patients who require prolonged mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-123-3-199508010-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Kollef, M. H., Shapiro, S. D., Fraser, V. J., Silver, P., Murphy, D. M., Trovillion, E., Hearns, M. L., Richards, R. D., Cracchilo, L., & Hossin, L.
Venue
Annals of Internal Medicine
Published
1995-08-01
Volume
123
Issue
3
Pages
168-174
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2054483044
Cited by
184
References
0
FWCI
8.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical Ventilation with or without 7-Day Circuit Changes: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.7326/0003-4819-123-3-199508010-00002
The paper
Kollef, M. H., Shapiro, S. D., Fraser, V. J., Silver, P., Murphy, D. M., Trovillion, E., Hearns, M. L., Richards, R. D., Cracchilo, L., & Hossin, L. (1995). Mechanical Ventilation with or without 7-Day Circuit Changes: A Randomized Controlled Trial. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-123-3-199508010-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.