Mechanical Ventilation with or without 7-Day Circuit Changes: A Randomized Controlled Trial
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine whether a practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with an increased incidence of nosocomial pneumonia. DESIGN: Randomized controlled trial. SETTING: Intensive care units in two university-affiliated teaching hospitals. PATIENTS: 300 patients admitted to an intensive care unit who required mechanical ventilation for more than 5 days. INTERVENTION: Patients were randomly assigned to receive either no routine ventilator circuit changes or circuit changes every 7 days. MEASUREMENTS: The primary outcome measure was the incidence of ventilator-associated pneumonia. Other outcome measures included duration of mechanical ventilation, length of hospital stay, and hospital mortality. RESULTS: 147 patients were randomly assigned to receive no routine ventilator circuit changes, and 153 patients were randomly assigned to receive circuit changes every 7 days. The two groups were similar at the time of randomization with regard to demographic characteristics, intensive care unit admission diagnoses, and severity of illness. Ventilator-associated pneumonia was seen in 36 patients (24.5%) receiving no routine changes and in 44 patients (28.8%) receiving changes every 7 days (relative risk, 0.85 [95% CI, 0.55 to 1.17]). No statistically significant differences for hospital mortality, intensive care unit mortality, death during mechanical ventilation, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups (P > or = 0.11). Patients receiving changes every 7 days had 247 circuit changes costing a total of $7410; patients receiving no routine changes had a total of 11 circuit changes costing $330. CONCLUSION: The elimination of routine ventilator circuit changes can reduce medical care costs without increasing the incidence of nosocomial pneumonia in patients who require prolonged mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200405-644st · Cited by 5,877
Ventilator-associated Pneumonia
Chastre, J., & Fagon, J.-Y. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.7.2105078 · Cited by 2,812
Clinical and economic consequences of ventilator-associated pneumonia: A systematic review
Safdar, N., Dezfulian, C., Collard, H. R., & Saint, S. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181731.53912.d9 · Cited by 1,086
Kollef, M. H., Shapiro, S. D., Silver, P., St. John, R. E., Prentice, D., Sauer, S., Ahrens, T. S., Shannon, W., & Baker-Clinkscale, D. (1997) · Critical Care Medicine · doi:10.1097/00003246-199704000-00004 · Cited by 827
Self-citationWarren, D. K., Shukla, S. J., Olsen, M. A., Kollef, M. H., Hollenbeak, C. S., Cox, M. J., Cohen, M. M., & Fraser, V. J. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000063087.93157.06 · Cited by 573
Self-citationEvidence-Based Clinical Practice Guideline for the Prevention of Ventilator-Associated Pneumonia
Dodek, P., Keenan, S., Cook, D., Heyland, D., Jacka, M., Hand, L., Muscedere, J., Foster, D., Mehta, N., Hall, R., et al. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-4-200408170-00011 · Cited by 546
Ventilator-Associated Pneumonia: Diagnosis, Treatment, and Prevention
Koenig, S. M., & Truwit, J. D. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.00051-05 · Cited by 539
Strategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals: 2014 Update
Klompas, M., Branson, R., Eichenwald, E. C., Greene, L. R., Howell, M. D., Lee, G., Magill, S. S., Maragakis, L. L., Priebe, G. P., Speck, K., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/677144 · Cited by 427
Ventilator-Associated Pneumonia
(2012) · SpringerReference · doi:10.1007/springerreference_225126 · Cited by 406
Klompas, M., Branson, R., Cawcutt, K., Crist, M., Eichenwald, E. C., Greene, L. R., Lee, G., Maragakis, L. L., Powell, K., Priebe, G. P., et al. (2022) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2022.88 · Cited by 402
Prevention of hospital-associated pneumonia and ventilator-associated pneumonia
Kollef, M. H. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000128569.09113.fb · Cited by 366
Self-citationStrategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals
Coffin, S. E., Klompas, M., Classen, D., Arias, K. M., Podgorny, K., Anderson, D. J., Burstin, H., Calfee, D. P., Dubberke, E. R., Fraser, V., et al. (2008) · Infection Control & Hospital Epidemiology · doi:10.1086/591062 · Cited by 341
Self-citationMasterton, R. G., Galloway, A., French, G., Street, M., Armstrong, J., Brown, E., Cleverley, J., Dilworth, P., Fry, C., Gascoigne, A. D., et al. (2008) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkn162 · Cited by 325
Kollef, M. H., Skubas, N. J., & Sundt, T. M. (1999) · Chest · doi:10.1378/chest.116.5.1339 · Cited by 308
Self-citationPrevention of Ventilator-Associated Pneumonia: An Evidence-Based Systematic Review
Collard, H. R., Saint, S., & Matthay, M. A. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-6-200303180-00015 · Cited by 304
Defining, treating and preventing hospital acquired pneumonia: European perspective
Torres, A., Ewig, S., Lode, H., Carlet, J., & For The European HAP working group (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1336-9 · Cited by 298
Muscedere, J., Dodek, P., Keenan, S., Fowler, R., Cook, D., & Heyland, D. (2008) · Journal of Critical Care · doi:10.1016/j.jcrc.2007.11.014 · Cited by 289
Rotstein, C., Evans, G., Born, A., Grossman, R., Light, R. B., Magder, S., McTaggart, B., Weiss, K., & Zhanel, G. G. (2008) · Canadian Journal of Infectious Diseases and Medical Microbiology · doi:10.1155/2008/593289 · Cited by 282
Kollef, M. H., Shapiro, S. D., Von Harz, B., Prentice, D., John, R. S., Silver, P., & Trovillion, E. (1997) · Chest · doi:10.1378/chest.112.3.765 · Cited by 226
Self-citationStrategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals: 2014 Update
Klompas, M., Branson, R., Eichenwald, E. C., Greene, L. R., Howell, M. D., Lee, G., Magill, S. S., L. Maragakis, L., P. Priebe, G., Speck, K., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1017/s0899823x00193894 · Cited by 196
(2010) · American Journal of Health-System Pharmacy · doi:10.2146/sp100001 · Cited by 176
Toward understanding evidence uptake: Semirecumbency for pneumonia prevention
Cook, D. J., Meade, M. O., Hand, L. E., & McMullin, J. P. (2002) · Critical Care Medicine · doi:10.1097/00003246-200207000-00012 · Cited by 159
“Participants also suggested that resources could be redirected from ineffective prophylactic interventions, such as frequent ventilator circuit changes, (36, 37) toward funding local quality improvement initiatives (38) promoting semirecumbency.”
BackgroundRISK FACTORS FOR NOSOCOMIAL PNEUMONIA
Fleming, C. A., Balaguera, H. U., & Craven, D. E. (2001) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70395-3 · Cited by 46
Metadata
- Authors
- Kollef, M. H., Shapiro, S. D., Fraser, V. J., Silver, P., Murphy, D. M., Trovillion, E., Hearns, M. L., Richards, R. D., Cracchilo, L., & Hossin, L.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1995-08-01
- Volume
- 123
- Issue
- 3
- Pages
- 168-174
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2054483044
- Cited by
- 184
- References
- 0
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.