The DOI matches its Crossref record.
Cardiac Event Recorders Yield More Diagnoses and Are More Cost-effective than 48-Hour Holter Monitoring in Patients with Palpitations: A Controlled Clinical Trial
Abstract
OBJECTIVE: To compare the diagnostic yield and cost-effectiveness of transtelephonic event monitors with those of Holter monitoring in patients with intermittent palpitations. DESIGN: Randomized crossover trial. SETTING: Diagnostic service of a teaching hospital and surrounding primary care practices. PATIENTS: 43 patients with previously uninvestigated palpitations who were referred for Holter monitoring. MEASUREMENTS: Patients were randomly allocated to receive an event monitor or 48-hour Holter monitor and then to receive the other device. Event monitors were used for 3 months or until two recordings were obtained while symptoms occurred. The main end point was an electrogram recorded during symptoms. The incremental cost-effectiveness of obtaining a diagnostic rhythm strip from event monitors was compared with that of Holter monitoring. RESULTS: The mean (+/- SD) patient age was 45 +/- 19 years; 37 patients (88%) were women. Event monitors were twice as likely to provide a diagnostic rhythm strip electrocardiogram during symptoms as 48-hour Holter monitoring (29 patients [67%] and 15 patients [35%], respectively; P < 0.001). Event monitors detected 8 patients (19%) with clinically important arrhythmias (6 patients with supraventricular tachycardia and 2 with atrial fibrillation or flutter), whereas the Holter monitors detected no significant arrhythmia (P < 0.005). With the event monitors, most patients transmitted an electrocardiogram recording by 6 weeks. Event monitors were dominant and therefore more cost-effective than 48-hour Holter monitoring, resulting in a cost savings of $213 for each additional diagnostic rhythm strip obtained during symptoms. CONCLUSIONS: Holter monitoring is a poor diagnostic test for intermittent palpitations. Event recorders provide better data and are more cost-effective.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Whereas these recorders can be useful in the investigation of palpitations, 163 they have a marginal role in the evaluation of syncope.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [163]
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
In the citing paper
“and provide a significantly higher yield than standard patient-activated loop recorders in patients with infrequent palpitations.49,73 -79”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [76]
In the citing paper
“The external and implantable loop recorders, mobile cardiac outpatient telemetry, and pacemakers and ICDs can detect asymptomatic clinically significant arrhythmias automatically (i.e. with no activation by the patient)”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [76]
Citations
Cited by
Sorted by citations
Items 101–200 of 244
Barrionuevo, J. D. D. A., Barón‐Esquivias, G., Martínez, Á. M., Cornejo, J. B., Rodríguez, A. N., Carrasco, A. P., Cabezas, J. J. S., Cayuela, A., & Fernández, J. M. C. (2002) · Revista Española de Cardiología · doi:10.1016/s0300-8932(02)76569-x · Cited by 11
A review of patient-led data acquisition for atrial fibrillation detection to prevent stroke
Kareem, M., Lei, N., Ali, A., Ciaccio, E. J., Acharya, U. R., & Faust, O. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102818 · Cited by 10
Assessment of an ECG event recorder in healthy dogs in a hospital environment
Eastwood, J. M., & Elwood, C. M. (2003) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2003.tb00138.x · Cited by 10
Frequency of Serious Arrhythmias Detected With Ambulatory Cardiac Telemetry
Kadish, A. H., Reiffel, J. A., Clauser, J., Prater, S. P., Menard, M., & Kopelman, H. A. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.12.047 · Cited by 10
Palpitations: a proper evaluation and approach to effective medical therapy
Pickett, C. C., & Zimetbaum, P. J. (2005) · Current Cardiology Reports · doi:10.1007/s11886-005-0090-7 · Cited by 9
How to use implantable loop recorders in clinical trials and hybrid therapy
Jung, W., Zvereva, V., Rillig, A., Roggenbuck, B., Sadeghzadeh, G., & Kohler, J. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9611-z · Cited by 9
Osaka, Y., Takigawa, M., Takahashi, A., Kuwahara, T., Okubo, K., Takahashi, Y., Tanaka, Y., Kawaguchi, N., Yamao, K., Watari, Y., et al. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.07.009 · Cited by 9
Holter monitoring: are two days better than one?
McClennen, S., ZIMETBAUM, P. J., Ho, K. K. L., & Goldberger, A. L. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01017-1 · Cited by 9
Chang, W.-L., Hou, C. J., Wei, S.-P., Tsai, J., Chen, Y.-J., Chen, M., Chuech, C.-C., Hung, C., Huang, M.-Y., Lee, C.-H., et al. (2015) · International journal of gerontology · doi:10.1016/j.ijge.2015.06.002 · Cited by 9
Guía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 23
Patient selection for ambulatory cardiac monitoring in the Indian healthcare environment
Shrivastav, M., Shrivastav, R., Makkar, J. S., & Biffi, M. (2013) · Heart Asia · doi:10.1136/heartasia-2012-010228 · Cited by 8
“62 The reduced upfront cost of lower-yielding diagnostics is often a red herring for more ef fi cacious, longer-duration monitoring methods.”
BackgroundMethodInfluentialIkeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2025) · Circulation Journal · doi:10.1253/circj.cj-24-0960 · Cited by 14
Akça, T., Uysal, F., Bostan, Ö., Genç, A., & Türkmen, H. (2021) · Pediatric Cardiology · doi:10.1007/s00246-021-02705-y · Cited by 7
The evaluationand management of palpitations
Keeler, E. R., Morris, R. K., Patolia, D. S., & Toy, E. C. (2002) · Primary Care Update for OB/GYNS · doi:10.1016/s1068-607x(02)00118-x · Cited by 7
Krahn, A. D., Renner, S., Klein, G. J., Yee, R. K., Skanes, A. C., & Evans, E. M. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00400.x · Cited by 7
Arnold, R. J. G., & Layton, A. J. (2015) · Journal of health economics and outcomes research · doi:10.36469/9897 · Cited by 7
Gula, L. J., Klein, G. J., Zurawska, U., Massel, D. R., Yee, R. K., Skanes, A. C., & Krahn, A. D. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02306.x · Cited by 7
“068† < = 3 months 4 (11) 3 (10) 3–12 months 7 (19) 7 (24) > = 12 months 25 (69) 19 (66)”
Möglichkeiten der Telemedizin: Telefon-EKG in der Notfallmedizin
Löllgen, H., Steinberg, T., Ertner, C., et al. (1998) · Intensivmedizin und Notfallmedizin · doi:10.1007/s003900050189 · Cited by 7
Israel, C. W., Ehrlich, J. R., Grönefeld, G., et al. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00189.x · Cited by 7
Trans-telephonic electrocardiographic monitoring—experience in India
Hs, R., Kishore, S., Bhatia, M. L., & Trehan, N. (1998) · Journal of Telemedicine and Telecare · doi:10.1258/1357633981931641 · Cited by 7
Automated Atrial Fibrillation Detection by ECG Signal Processing: A Review
Giraldo-Guzmán, J., Contreras-Ortiz, S. H., Kotas, M., Castells, F., & Moroń, T. (2021) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2022041650 · Cited by 6
“|γ(t, f )| = |Hx→y(t, f )Hy→x(t, f )| (13)”
Huisartsen kunnen de kans op hartritmestoornissen vaak niet goed inschatten
Hoefman, E., Boer, K. R., van Weert, H. C. P. M., et al. (2008) · Huisarts en Wetenschap · doi:10.1007/bf03086812 · Cited by 6
Diagnosing atrial fibrillation in general practice
van Weert, H. C. P. M. (2007) · BMJ · doi:10.1136/bmj.39266.497396.be · Cited by 6
Bo, M., & Rosso, A. D. (2022) · Minerva Medica · doi:10.23736/s0026-4806.21.07531-5 · Cited by 6
Emergency Management of Palpitations in the Elderly
Jamshed, N., Dubin, J. S., & ELDADAH, Z. A. (2012) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2012.10.003 · Cited by 6
Evaluación del síncope de alto riesgo remitido desde el Servicio de Urgencias
Romero-Rodríguez, N., Barón‐Esquivias, G., Gómez-Moreno, S., Barrionuevo, J. D. D. A., Pedrote, A. A., & Martínez, Á. M. (2010) · Revista Clínica Española · doi:10.1016/j.rce.2009.05.005 · Cited by 6
Freedman, R. A. (2001) · Cardiac Electrophysiology Review · doi:10.1023/a:1011424312828 · Cited by 6
Pines, J. M., & Everett, W. W. (2008) · Wiley eBooks · doi:10.1002/9781444300772 · Cited by 6
Iga, K., Izumi, C., Nakano, A., Sakanoue, Y., Miyamoto, T., Kitaguchi, S., Himura, Y., Gen, H., & Konishi, T. (1998) · Internal Medicine · doi:10.2169/internalmedicine.37.1005 · Cited by 6
The implantable loop recorder in children: searching for indications
Pass, R. H., & Liberman, L. (2008) · Heart · doi:10.1136/hrt.2007.126276 · Cited by 5
Evaluation of Children With Palpitations
Rivera, R. F., Chambers, P., & Ceresnak, S. R. (2011) · Clinical Pediatric Emergency Medicine · doi:10.1016/j.cpem.2011.09.002 · Cited by 5
Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.008 · Cited by 4
Supervised SVM Transfer Learning for Modality-Specific Artefact Detection in ECG
Moeyersons, J., Morales, J., Villa, A., Castro, I. D., Testelmans, D., Buyse, B., Hoof, C. A. V., Willems, R., Huffel, S. V., & Varon, C. (2021) · Sensors · doi:10.3390/s21020662 · Cited by 4
“It is stated in [5] that recordings acquired during up to 3 months are beneficial for this task.”
BackgroundKabe, I., Koga, Y., Kochi, T., & Mizoue, T. (2014) · Journal of Occupational Health · doi:10.1539/joh.14-0092-fs · Cited by 4
Brandes, A., & Bethge, K.-P. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0010-9 · Cited by 5
NHG-Standaard Atriumfibrilleren
Boode, B. S. P., Heeringa, J., Konings, K., Rutten, F., den Berg, P. V., Zwietering, P. J., van Lieshout, J., & Opstelten, W. (2011) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-8279-8_18 · Cited by 4
Hoefman, E., van Weert, H., Reitsma, J. B., Koster, R. W., & Bindels, P. (2005) · Huisarts en Wetenschap · doi:10.1007/bf03084157 · Cited by 4
Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Nazzari, H., Halperin, L. F., & Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99770-9 · Cited by 3
Irie, S., & Tada, H. (2023) · International Heart Journal · doi:10.1536/ihj.22-436 · Cited by 3
Palpitations in athletes: diagnosis, workup and treatment
Parisi, E. J., & Chung, E. H. (2023) · Heart · doi:10.1136/heartjnl-2022-321726 · Cited by 3
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 5
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.003 · Cited by 3
MsFLASH analysis of diurnal salivary cortisol and palpitations in peri- and postmenopausal women
Carpenter, J. S., Tisdale, J. E., Larson, J. C., Sheng, Y., Chen, C. X., Ah, D. M. V., Kovacs, R. J., Reed, S. D., Thurston, R. C., & Guthrie, K. A. (2021) · Menopause The Journal of The North American Menopause Society · doi:10.1097/gme.0000000000001897 · Cited by 3
Diagnosis effectiveness of arrhythmia with R-test electrocardiogram in old fallers
Midttun, M. (2011) · European Geriatric Medicine · doi:10.1016/j.eurger.2011.07.005 · Cited by 3
Appropriateness of ECG Holter requests in an outpatient service: a prospective study
Piccirilli, S., Gallagher, M. M., Vellini, M., Padula, M., Voumvourakis, A., Santini, L., Magliano, G., & Romeo, F. (2007) · Journal of Cardiovascular Medicine · doi:10.2459/01.jcm.0000278449.96988.82 · Cited by 3
Electrocardiology, N., Kadish, A. H., Buxton, A. E., Winters, W. L., & Boone, A. W. (2001) · Cited by 3
Klenck, C. (2007) · Current Sports Medicine Reports · doi:10.1007/s11932-007-0008-9 · Cited by 3
Enfoque semiológico de las palpitaciones
Gaviria, M. Á., Bustos, C. H., & Mora, G. (2014) · Revista de la Facultad de Medicina · doi:10.15446/revfacmed.v62n1.43779 · Cited by 3
Paroxysmal atrial fibrillation is uncommon in outpatients with chronic heart failure
Corell, P., Gustafsson, F., Mehlsen, J., et al. (2008) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430801899734 · Cited by 3
“Longer monitoring may had elucidated more episodes of PAF (13).”
BackgroundIkeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2025) · Journal of Arrhythmia · doi:10.1002/joa3.70059 · Cited by 3
“76 In the case of symptoms that occur suddenly, self-recording by patients is impossible, so it is recommended that a patch ECG device or an external loop ECG device is used.”
Real‐Time Ambulatory ECG Does Not Expedite Care
Feuerborn, M., Torre, M., Lyons, A., Bunch, T. J., & Steinberg, B. A. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.124.036520 · Cited by 2
Evaluation of the Patient with Palpitations and Non-life-threatening Cardiac Arrhythmias
Spratt, K. A., & Michelson, E. L. (2001) · doi:10.1007/978-1-4615-6601-4_8 · Cited by 2
Evaluation of Patients with Palpitations: Cardiac Event Recorder Versus 48‐hour Holter Monitoring
Makowska, E., Szymot, J., Soszyriska, M., & Kułakowski, P. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00068.x · Cited by 2
An introduction to ambulatory electrocardiography
Richley, D. (2010) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2010.5.1.46025 · Cited by 2
Brunetti, N. D., D’Arienzo, G., Tiscia, G., Pellegrino, P. L., Gennaro, L. D., & Biase, M. D. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.055 · Cited by 2
Novel Time-Frequency Features for Normal Ecg
Alothmany, N., Kashkari, R., Shaibah, I., et al. (2012) · DergiPark (Istanbul University) · Cited by 2
Güvenç, T. S., Güvenç, R. Ç., Velibey, Y., Tanık, V. O., Öz, D., & Eren, M. (2016) · Medical Hypotheses · doi:10.1016/j.mehy.2016.05.001 · Cited by 2
“When the episodes are infrequent, long term monitoring with an external loop recorder (ELR) or even an implantable loop recorder (ILR) is indicated [5,6].”
BackgroundJabbour, F., & Kanmanthareddy, A. (2019) · StatPearls · Cited by 2
Garg, S., Saha, A., & Clark, A. L. (2006) · Clinical Medicine · doi:10.7861/clinmedicine.6-6-586 · Cited by 2
Evaluation and Management of Syncope
Grubb, B. P., & KOSINSKI, D. J. (2002) · Contemporary cardiology · doi:10.1007/978-1-59259-090-2_10 · Cited by 2
Freedman, R. A. (1999) · Cardiac Electrophysiology Review · doi:10.1023/a:1009943805669 · Cited by 2
Diagnosis of Arrhythmias with Non-invasive Tools
Sullivan, R. M., Li, W. W., Kendig, A. C., & Olshansky, B. (2010) · Humana Press eBooks · doi:10.1007/978-1-60761-161-5_5 · Cited by 1
Muñoz, D. R., Jiménez, J. R., Castillo, A. M. D., Granero, C. L., Garcı́a-Alberola, A., Sánchez, D. J., Beltrán, C. G., Ramos-Ruiz, P., Arias, M. A., Nubila, B. C. L. S. D., et al. (2023) · American Heart Journal · doi:10.1016/j.ahj.2023.11.016 · Cited by 1
Srivatsav, A., Thompson, Z., Bruno, M. A., Stephens, S. B., Gutierrez, M. E., Miyake, C. Y., Morris, S. A., Pham, T. D., Valdés, S. O., Kim, J. J., et al. (2024) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.15087 · Cited by 1
“While these monitors appear to be more effective than Holter monitors due to their longer duration in adults [11–13], they remain a time-intensive diagnostic tool and require prolonged patient adherence.”
Ikeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2024) · Japanese Journal of Electrocardiology · doi:10.5105/jse.44.275 · Cited by 1
The Economic and Health Policy Impact of Wearable Devices in Healthcare
Davidson, K. P. (2025) · Information systems engineering and management · doi:10.1007/978-3-031-98897-4_1 · Cited by 1
DeFauw, M., Nair, V. N., & Yang, Y. (2012) · IIE Transactions on Healthcare Systems Engineering · doi:10.1080/19488300.2012.680004 · Cited by 1
Clinical Logistics in 24-Hour Ambulatory Electrocardiographic Monitoring
RuDusky, B. M. (2003) · Angiology · doi:10.1177/000331970305400508 · Cited by 1
OBSOLETE: Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99770-8 · Cited by 1
Özer, S., Çetın, M., Özyıldız, A. G., Gengörü, R., Turan, O. E., Puşuroğlu, M., Bahçeci, B., & Erdoğan, T. (2020) · Journal of the Saudi Heart Association · doi:10.37616/2212-5043.1049 · Cited by 1
van Weert, H. C. P. M. (2013) · Bijblijven · doi:10.1007/s12414-013-0075-1 · Cited by 1
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 1
Ambulatory Electrocardiography
Flinders, D., & Akin, S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-05267-2.00087-x · Cited by 1
Innovative technologies for the cardiac patient and their effects
Eggett, C. (2015) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2015.10.8.370 · Cited by 1
Lucassen, W. A. M., Himmelreich, J. C. L., Harskamp, R. E., & Selder, J. L. (2021) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2620-4_30 · Cited by 1
Managing Atrial Fibrillation in Active Patients and Athletes
Reiss, R. A., & Christie, D. M. (1999) · The Physician and Sportsmedicine · doi:10.3810/psm.1999.03.730 · Cited by 1
Hendrikx, T. (2015) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 1
Colman, N., Wieling, W., & Freeman, R. (2003) · Elsevier eBooks · doi:10.1016/b978-012125831-3/50300-2 · Cited by 1
Evaluation of the Patient with Syncope
Blatt, C. M., & Graboys, T. B. (2001) · doi:10.1007/978-1-4615-6601-4_9
Cardiovascular Evaluation of Patients with Syncope of Uncertain Etiology
Grubb, B. P., & KOSINSKI, D. J. (1997) · Cardiac Electrophysiology Review · doi:10.1023/a:1009933417529 · Cited by 1
Ambulatory Electrocardiography, Transient Event Monitors, and Continuous Loop Recorders
Kreeger, R. W., Brooks, J., & Movahed, A. (2008) · Springer eBooks · doi:10.1007/978-3-540-78674-0_9
ECGs and Other Recording Devices
PhD, C. W. (2011) · doi:10.1002/9781119979487.ch2
PhD, C. W. (2011) · doi:10.1002/9781119979487.ch3
Investigation of collapse in small animals
Patteson, M. W. (2014) · Companion animal · doi:10.12968/coan.2014.19.10.500
Guzmán, J. C., & Morillo, C. A. (2014) · Springer eBooks · doi:10.1007/978-3-319-09102-0_22
Zimerman, L. I., Medeiros, C. M., & Ribeiro, J. P. (1998) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x1998000300010
Conduite à tenir face à des palpitations
Frank, R., & Hidden‐Lucet, F. (2009) · EMC - Traité de médecine AKOS · doi:10.1016/s1634-6939(09)50038-5
Como actuar en caso de palpitaciones
Frank, R., & Hidden‐Lucet, F. (2009) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(09)70525-2
Schuchert, A., Behrens, G., & Meinertz, T. (2000) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/bf03042533
“Diskussion Langzeit-EKG-Aufzeichnungen sind unzureichend, um den Herzrhythrnus zum Zeitpunkt seltener, kurzanhaltender Beschwerden ohne BewuBtseinsverlust aufzuzeichnen (1).”
BackgroundWeintraub, W. S. (2007) · Springer eBooks · doi:10.1007/978-1-84628-715-2_136
Görenek, B., Kudaiberdieva, G., Çavuşoğlu, Y., Göktekín, Ö., Ata, N., Ünalır, A., Birdane, A., & Timuralp, B. (2001) · Angiology · doi:10.1177/000331970105201108
Condotta da tenere di fronte alle palpitazioni
Frank, R., & Hidden‐Lucet, F. (2010) · EMC - AKOS - Trattato di Medicina · doi:10.1016/s1634-7358(10)70330-2
Remote Monitoring for Atrial Fibrillation
Man, J. P., Kapa, S., & Dixit, S. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.05.008
Pass, R. H., & Ceresnak, S. R. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4619-3_221
Future Trends in the Evolution of Remote Monitoring and Physiologic Sensing Technologies
Kapa, S., Man, J. P., & Supple, G. E. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.05.010
Lewalter, T. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0018-1
“Diese wie auch weitere Untersuchungen weisen darauf hin, dass bei Palpitationen, die nicht sicher täglich auftreten, der diagnostische Wert und die Kosten-Effizienz des diskontinuierlichen Event-Recording dem eines konventionellen Langzeit-EKGs überlegen ist [6].”
BackgroundSyncope Due to Advanced Atrioventricular Block Despite No Demonstrable Cardiac Disease
KOSINSKI, D. J., & Grubb, B. P. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb05509.x
Utility of the Implantable Loop Recorder: Current Status
Giada, F., CORBUCCI, G., & Raviele, A. (2008) · Hospital chronicles/Hospital Chronicles
Il cardiopalmo: iter diagnostico
Giada, F., & Raviele, A. (2010) · Giornale italiano di cardiologia · doi:10.1714/660.7680
Knocking on heaven’s door. De diagnostiek van hartkloppingen
van Weert, H. C. P. M. (2006) · Bijblijven · doi:10.1007/bf03059922
Metadata
- Authors
- Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J.
- Affiliations
- John Hunter Hospital (AU)
- Corresponding author
- Kinlay, Scott
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1996-01-01
- Volume
- 124
- Issue
- 1_Part_1
- Pages
- 16-20
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2028013985
- Cited by
- 245
- References
- 0
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 3 · 2023: 5 · 2022: 2 · 2021: 9 · 2020: 7 · 2019: 4 · 2018: 9 · 2017: 7 · 2016: 6 · 2015: 9 · 2014: 9 · 2013: 14 · 2012: 8
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- Holter monitoring, cost-effectiveness, diagnostic yield, supraventricular tachycardia, atrial fibrillation, arrhythmia detection, transtelephonic monitoring, electrocardiogram
- MeSH terms
- Adult, Arrhythmias, Cardiac, Atrial Fibrillation, Cost-Benefit Analysis, Electrocardiography, Female, Humans, Male, Middle Aged, Electrocardiography, Ambulatory, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review