CoChat

Diagnostic yield of automatic and patient‐triggered ambulatory cardiac event recording in the evaluation of patients with palpitations, dizziness, or syncope

Open access
Balmelli, Nicola, Naegeli, Barbara, Bertel, Osmund · 2003 · Clinical Cardiology

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index; none of the 20 sources its claims cite is checked for support yet.

Abstract

BACKGROUND: Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24-h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms. HYPOTHESIS: The aim of this study was to determine the diagnostic yield of a patient-triggered CER combined with continuous automatic arrhythmia detection in the evaluation of sporadic dizziness/syncope or palpitations and its clinical relevance in assessing the further management. METHODS: We investigated 101 consecutive outpatients (54 +/- 20 years, 40 women), referred for evaluation of sporadic dizziness and syncope (36%) or palpitations (64%) of suspected rhythmogenic origin. All were monitored by patient-triggered CER with continuous automatic arrhythmia detection. RESULTS: After a mean monitoring period of 103 +/- 38 h, 83 patients registered symptoms and 57 patients had diagnostic or therapeutic relevant arrhythmias (relA). A total of 196 episodes of relA were recorded; 31 (16%) episodes were patient-triggered and 165 (84%) automatically recorded. Diagnostic relevant episodes (relA and/or typical symptoms) occurred in 94 patients, in 54% after the first 24 h of monitoring. According to the results of the CER, 80 patients needed no further diagnostic evaluation; 20 had additional diagnostic tests. CONCLUSIONS: Cardiac event recorders with a continuous automatic arrhythmia detection function are a well-tolerated device for sporadic, potentially arrhythmia-related symptoms. The patient-triggered mode alone is not sufficiently reliable; the automatic continuous arrhythmia detection function has additional diagnostic and therapeutic consequences. In 54% of all patients, the first diagnostic event would not have been recorded with a single conventional 24-h-Holter ECG.

Overview

CoChat Summary

TL;DR

In 101 outpatients with sporadic palpitations, dizziness, or syncope, combined automatic and patient-triggered cardiac event recording found relevant arrhythmias in 57 patients and diagnostic-relevant episodes in 94. Automatic detection captured 84% of relevant arrhythmia episodes, and 54% of first diagnostic events occurred after the first 24 h, suggesting patient-triggered recording alone is insufficient.

Key findings

  • After mean monitoring of 103 ± 38 h, 83 patients registered symptoms and 57 had relevant arrhythmias; 196 relevant arrhythmia episodes were recorded (1.94 per patient): 8 ventricular tachycardia, 14 ventricular bigeminus, 33 atrial fibrillation/flutter, 92 supraventricular tachycardia, 42 bradycardias, and 7 pauses.
  • Of 196 relevant arrhythmia episodes, 31 (16%) were patient-triggered and 165 (84%) were automatically recorded. Among 18 asymptomatic patients, 11 (61%) had relevant arrhythmias detected only by automatic arrhythmia detection.
  • Diagnostic-relevant episodes (relevant arrhythmia and/or typical symptoms) occurred in 94 patients; in 54% the first event occurred after the first 24 h and would have been missed by a single 24-h Holter ECG. CER results led to no further evaluation in 80 patients, additional diagnostic tests in 20, therapy in 23, and reassurance in 57.
  • Diagnostic yield was higher with structural heart disease: 72% (38/53) had relevant arrhythmias versus 40% (17/48) without structural heart disease, while symptom registration was similar (81% vs 83%).

Methods

  • Prospective study of 101 consecutive outpatients referred for sporadic (<1 episode/day) dizziness/syncope (36%) or palpitations (64%) of suspected rhythmogenic origin; mean age 54 ± 20 years, 40 women. Patients with daily symptoms or a cause identified by basic workup were excluded.
  • All patients were monitored with a commercially available cardiac event recorder (R-Test Evolution, Novacor, France) combining patient-triggered recordings with continuous automatic arrhythmia detection for up to 7 days; pre- and post-triggering delays were 20 and 10 s.
  • ECG strips from all patient-triggered and automatically recorded events were analyzed independently by two cardiologists blinded to the study. Relevant arrhythmias were predefined as ventricular tachycardia (>100 beats/min and ≥3 beats), ventricular bigeminus, supraventricular tachycardia (>100 beats/min and ≥3 beats), atrial fibrillation or flutter, bradycardia (<40 beats/min), and pauses (RR interval ≥3 s).

Limitations

  • Stated: the study had a relatively small sample of patients studied in a tertiary referral center.
  • Stated: there was no recording during hours when the CER was not in place (e.g., during bathing), with the possibility of missing relevant events; also, 52% of patients had known cardiovascular pathology and were likely to have an arrhythmia within the week of monitoring, so benefit may be greatest in patients with a higher likelihood of an event and may not apply to those without structural heart disease who experience arrhythmic events more rarely.
  • Evident: this was a single-center observational study without a concurrent control group; comparisons with 24-h Holter ECG and other cardiac event recorder studies are indirect.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1002/clc.4960260405

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 10 Not checked · 33 Own results and interpretations

17 more claims

Create a free account to see all 44 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 14
  • It may state two separate claims as one. 11

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 8 references

Research works printed but not linked: 1

  1. Simonetti G, 1998, Prospektive Vergleichsuntersuchung eines Aktivierungs‐Holters mit einem konventionellen Holter‐EKG bei Patienten mit Synkopen, Präsynkopen and Palpitationen, Schweiz Med Wochenschr, 128, 29S

Cited by

See all 35

Metadata

Authors
Balmelli, N., Naegeli, B., & Bertel, O.
Affiliations
Triemli Hospital (CH)
Corresponding author
Naegeli, Barbara
Venue
Clinical Cardiology
Publisher
Wiley
Published
2003-04
Volume
26
Issue
4
Pages
173-176
ISSN
  • 0160-9289 (ISSN-L)
  • 1932-8737
OpenAlex
W1968170366
Cited by
35
References
8
Citations by year
2026: 2 · 2023: 1 · 2022: 1 · 2021: 2 · 2018: 3 · 2017: 2 · 2016: 3 · 2014: 1 · 2013: 1 · 2012: 2
FWCI
1.60
Type
journal article
Language
en
Open access
Locations
  • Clinical Cardiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
automatic arrhythmia detection, ambulatory cardiac monitoring, palpitations, syncope, dizziness, arrhythmia diagnosis, diagnostic yield
MeSH terms
Arrhythmias, Cardiac, Dizziness, Electrocardiography, Female, Humans, Male, Middle Aged, Syncope, Electrocardiography, Ambulatory, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic yield of automatic and patient‐triggered ambulatory cardiac event recording in the evaluation of patients with palpitations, dizziness, or syncope. https://app.cochat.ai/papers/10.1002/clc.4960260405
The paper
Balmelli, N., Naegeli, B., & Bertel, O. (2003). Diagnostic yield of automatic and patient‐triggered ambulatory cardiac event recording in the evaluation of patients with palpitations, dizziness, or syncope. Clinical Cardiology. https://doi.org/10.1002/clc.4960260405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.