Efficacy of Automatic Continuous Positive Airway Pressure Therapy That Uses an Estimated Required Pressure in the Treatment of the Obstructive Sleep Apnea Syndrome
The DOI matches its Crossref record.
Abstract
BACKGROUND: Continuous positive airway pressure (CPAP) is effective therapy for the obstructive sleep apnea syndrome (OSAS). Automatic CPAP devices continuously adjust the positive pressure to the required levels. OBJECTIVE: To determine the efficacy of an automatic CPAP machine used with an estimated reference pressure value. DESIGN: A before-and-after, single-blind trial in which patients were randomly allocated to one of three modes of CPAP administration. SETTING: Referral-based sleep center in a public health care institution. PATIENTS: 36 outpatients with OSAS. INTERVENTION: Continuous positive airway pressure was given at a conventional fixed pressure (group 1), automatic CPAP was given at a measured reference pressure (group 2), and automatic CPAP was given at an estimated reference pressure (group 3). In group 1, the effective pressure was determined during a titration sleep study. In groups 2 and 3, the pressure interval was allowed to vary from 4 cm H2O below reference pressure to 3 cm H2O above reference pressure. In group 3, the estimated value of the reference pressure was determined according to individual anthropometric characteristics. MEASUREMENTS: Sleep studies were performed and measurements of diurnal sleepiness were obtained at each visit. RESULTS: Sleep and breathing disorders and hypersomnolence were alleviated similarly in the three groups. The apnea + hypopnea index remained abnormal in one patient in group 3 for whom the reference pressure had been underestimated. A strong negative correlation was found between the percentage of time spent below reference pressure during CPAP and the difference between the effective and estimated pressures. CONCLUSION: Automatic CPAP can be used with an estimated reference pressure without doing a titration sleep study. The positive pressure trend can be used to determine whether treatment failure is caused by an inadequate pressure setting and to determine the amount of pressure to apply.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of Positive Airway Pressure Treatment for Sleep Related Breathing Disorders in Adults
Gay, P., Weaver, T., Loube, D., & Iber, C. (2006) · Sleep · doi:10.1093/sleep/29.3.381 · Cited by 614
Pulmonary Complications of Obesity
Koenig, S. M. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200104000-00006 · Cited by 530
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Indications for Positive Airway Pressure Treatment of Adult Obstructive Sleep Apnea Patients
Loube, D. I., Gay, P. C., Strohl, K. P., Pack, A. I., White, D. P., & Collop, N. A. (1999) · Chest · doi:10.1378/chest.115.3.863 · Cited by 363
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Masa, J. F., Jiménez, A., Durán, J., Capote, F., Monasterio, C., Mayos, M., Terán, J., Hernández, L., Barbé, F., Maimó, A., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200312-1787oc · Cited by 328
Qaseem, A., Holty, J.-E. C., Owens, D. K., Dallas, P., Starkey, M., & Shekelle, P. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-7-201310010-00704 · Cited by 305
Ayas, N. T., Patel, S. R., Malhotra, A., Schulzer, M., Malhotra, M., Jung, D., Fleetham, J., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.2.249 · Cited by 255
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Ip, S., D'Ambrosio, C., Patel, K., Obadan, N., Kitsios, G. D., Chung, M., & Balk, E. M. (2012) · Systematic Reviews · doi:10.1186/2046-4053-1-20 · Cited by 148
“Seven of eight trials found no statistically significant difference in slow wave sleep (stages 3 or 4) [13,14,20,24,26,27,31,32].”
BackgroundInfluentialConstant vs Automatic Continuous Positive Airway Pressure Therapy
d'Ortho, M.-P., Grillier-Lanoir, V., Levy, P., Goldenberg, F., Corriger, E., Harf, A., & Lofaso, F. (2000) · Chest · doi:10.1378/chest.118.4.1010 · Cited by 103
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-542oc · Cited by 73
Nussbaumer, Y., Bloch, K. E., Genser, T., & Thurnheer, R. (2006) · Chest · doi:10.1378/chest.129.3.638 · Cited by 63
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
Meurice, J. C., Cornette, A., Philip-Joet, F., Pepin, J. L., Escourrou, P., Ingrand, P., & Veale, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.019 · Cited by 52
Galetke, W., Anduleit, N., Richter, K., Stieglitz, S., & Randerath, W. J. (2008) · Respiration · doi:10.1159/000097767 · Cited by 49
Kennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
The use of a predicted CPAP equation improves CPAP titration success
Rowley, J. A., Tarbichi, A. G. S., & Badr, M. S. (2005) · Sleep and Breathing · doi:10.1007/s11325-005-0004-3 · Cited by 42
“However, this contrasts with another study in which it was shown that the equation could be used to help set the estimated reference pressure for an autotitrating CPAP unit [24].”
ResultHussain, S. F., Love, L., Burt, H., & Fleetham, J. A. (2004) · Respiratory Medicine · doi:10.1016/j.rmed.2003.11.002 · Cited by 37
Bureau, M. P. (2000) · Thorax · doi:10.1136/thorax.55.9.741 · Cited by 23
Ebben, M. R., Narizhnaya, M., & Krieger, A. C. (2017) · Sleep and Breathing · doi:10.1007/s11325-016-1436-7 · Cited by 13
Metadata
- Authors
- Series, F., & Marc, I.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1997-10-15
- Volume
- 127
- Issue
- 8_Part_1
- Pages
- 588-595
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2012079564
- Cited by
- 82
- References
- 0
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.