Chlorhexidine Compared with Povidone-Iodine Solution for Vascular Catheter–Site Care: A Meta-Analysis

Chaiyakunapruk, Nathorn, Veenstra, David L., Lipsky, Benjamin A., Saint, Sanjay·2002·Annals of Internal Medicine

Abstract

PURPOSE: Bloodstream infections related to use of catheters, particularly central-line catheters, are an important cause of patient morbidity, mortality, and increased health care costs. This study evaluated the efficacy of skin disinfection with chlorhexidine gluconate compared with povidone-iodine solution in preventing catheter-related bloodstream infection. DATA SOURCES: Multiple computerized databases (1966 to 2001), reference lists of identified articles, and queries of principal investigators and antiseptic manufacturers. STUDY SELECTION: Randomized, controlled trials comparing chlorhexidine gluconate with povidone-iodine solutions for catheter-site care. DATA EXTRACTION: Using a standardized form, two reviewers abstracted data on study design, patient population, intervention, and incidence of catheter-related bloodstream infection from all included studies. DATA SYNTHESIS: Eight studies involving a total of 4143 catheters met the inclusion criteria. All studies were conducted in a hospital setting, and various catheter types were used. The summary risk ratio for catheter-related bloodstream infection was 0.49 (95% CI, 0.28 to 0.88) in patients whose catheter sites were disinfected with chlorhexidine gluconate instead of povidone-iodine. Among patients with a central vascular catheter, chlorhexidine gluconate reduced the risk for catheter-related bloodstream infection by 49% (risk ratio, 0.51 [CI, 0.27 to 0.97]). CONCLUSIONS: These results suggest that incidence of bloodstream infections is significantly reduced in patients with central vascular lines who receive chlorhexidine gluconate versus povidone-iodine for insertion-site skin disinfection. Use of chlorhexidine gluconate is a simple and effective means of reducing vascular catheter-related infections.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-136-11-200206040-00007

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 610

Metadata

Authors
Chaiyakunapruk, N., Veenstra, D. L., Lipsky, B. A., & Saint, S.
Venue
Annals of Internal Medicine
Published
2002-06-04
Volume
136
Issue
11
Pages
792-801
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2010074829
Cited by
610
References
21
FWCI
28.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chlorhexidine Compared with Povidone-Iodine Solution for Vascular Catheter–Site Care: A Meta-Analysis. https://app.cochat.ai/papers/10.7326/0003-4819-136-11-200206040-00007
The paper
Chaiyakunapruk, N., Veenstra, D. L., Lipsky, B. A., & Saint, S. (2002). Chlorhexidine Compared with Povidone-Iodine Solution for Vascular Catheter–Site Care: A Meta-Analysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-136-11-200206040-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.