CoChat

Identification of Persons at High Risk for Type 2 Diabetes Mellitus: Do We Need the Oral Glucose Tolerance Test?

Stern, Michael P., Williams, Ken, Haffner, Steven M. · 2002 · Annals of Internal Medicine
Cited by 510

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The standard method of identifying persons at high risk for type 2 diabetes mellitus involves detection of impaired glucose tolerance, which requires a costly and inconvenient 2-hour oral glucose tolerance test. Because clinical trials have indicated that diabetes is preventable by using behavioral or pharmacologic interventions, less expensive methods of identifying high-risk persons are needed. OBJECTIVE: To determine whether multivariable models are superior to glucose tolerance tests for identifying persons at high risk for diabetes mellitus. DESIGN: Prospective cohort study. SETTING: San Antonio, Texas. PARTICIPANTS: 1791 Mexican Americans and 1112 non-Hispanic whites without diabetes at baseline who were randomly selected from census tracts. MEASUREMENTS: Medical history; body mass index; blood pressure; fasting and 2-hour plasma glucose levels; fasting serum total, low-density lipoprotein, and high-density lipoprotein cholesterol levels; and triglyceride level. RESULTS: For prediction of 7.5-year incidence of type 2 diabetes, the area under the receiver-operating characteristic (ROC) curve for a multivariable model involving readily available clinical variables was significantly (P < 0.001) greater than the area under the ROC curve for the 2-hour glucose value alone (84.3% vs. 77.5%). Impaired glucose tolerance represents a single point on the latter curve. Adding the 2-hour glucose measurement to the multivariable model increased the area under its ROC curve, but only from 84.3% to 85.7%. CONCLUSION: Persons at high risk for diabetes mellitus are better identified by using a simple prediction model than by relying exclusively on the results of a 2-hour oral glucose tolerance test. Although adding the 2-hour glucose variable to the model enhanced prediction, the resulting slight improvement entails greater cost and inconvenience.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-136-8-200204160-00006

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 510

Metadata

Authors
Stern, M. P., Williams, K., & Haffner, S. M.
Venue
Annals of Internal Medicine
Published
2002-04-16
Volume
136
Issue
8
Pages
575-581
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2106734747
Cited by
510
References
16
FWCI
14.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of Persons at High Risk for Type 2 Diabetes Mellitus: Do We Need the Oral Glucose Tolerance Test? https://app.cochat.ai/papers/10.7326/0003-4819-136-8-200204160-00006
The paper
Stern, M. P., Williams, K., & Haffner, S. M. (2002). Identification of Persons at High Risk for Type 2 Diabetes Mellitus: Do We Need the Oral Glucose Tolerance Test? Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-136-8-200204160-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.