The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Accuracy of Computed Tomographic Angiography and Magnetic Resonance Angiography for Diagnosing Renal Artery Stenosis
Abstract
BACKGROUND: Timely, accurate detection of renal artery stenosis is important because this disorder may be a potentially curable cause of hypertension and renal impairment. OBJECTIVE: To determine the validity of computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) compared with digital subtraction angiography (DSA) for detection of renal artery stenosis. DESIGN: Prospective multicenter comparative study conducted from 1998 to 2001. Two panels of 3 observers judged CTA and MRA image data and were blinded to all other results. Digital subtraction angiography images were evaluated by consensus. SETTING: 3 large teaching hospitals and 3 university hospitals in the Netherlands. PATIENTS: 402 hypertensive patients with suspected renal artery stenosis were included. A group of 356 patients who underwent all 3 diagnostic tests was used for analysis. MEASUREMENTS: Reproducibility was assessed by calculating interobserver agreement. Diagnostic performance was evaluated in terms of sensitivity, specificity, and other diagnostic variables. Atherosclerotic stenoses of 50% or greater and fibromuscular dysplasia were considered clinically relevant. RESULTS: Twenty percent of patients who underwent all 3 tests had clinically relevant renal artery stenosis. Moderate interobserver agreement was found, with kappa values ranging from 0.59 to 0.64 for CTA and 0.40 to 0.51 for MRA. The combined sensitivity and specificity were 64% (95% CI, 55% to 73%) and 92% (CI, 90% to 95%) for CTA and 62% (CI, 54% to 71%) and 84% (CI, 81% to 87%) for MRA. LIMITATIONS: Eighteen percent of the patients were included nonconsecutively. Digital subtraction angiography may be an imperfect reference test. CONCLUSION: Computed tomographic angiography and MRA are not reproducible or sensitive enough to rule out renal artery stenosis in hypertensive patients. Therefore, DSA remains the diagnostic method of choice. *For a list of the other investigators and research coordinators who participated in RADISH, see the Appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Safian, R. D., & Textor, S. C. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102083440607 · Cited by 1,068
Arteriographic complications in the DSA era.
Waugh, J. R., & Sacharias, N. (1992) · Radiology · doi:10.1148/radiology.182.1.1727290 · Cited by 469
Vasbinder, G. B. C., Nelemans, P. J., Kessels, A. G. H., Kroon, A. A., de Leeuw, P. W., & van Engelshoven, J. M. A. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-6-200109180-00009 · Cited by 387
Self-citationThe Effect of Conditional Dependence on the Evaluation of Diagnostic Tests
Vacek, P. M. (1985) · Biometrics · doi:10.2307/2530967 · Cited by 317
A Clinical Prediction Rule for Renal Artery Stenosis
Krijnen, P., van Jaarsveld, B. C., Steyerberg, E. W., Man in 't Veld, A. J., Schalekamp, M. A. D. H., & Habbema, J. D. F. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-9-199811010-00005 · Cited by 209
Detection, Evaluation, and Treatment of Renovascular Hypertension: Final Report
(1987) · Archives of Internal Medicine · doi:10.1001/archinte.1987.00370050016004 · Cited by 161
Inter-observer variability in the angiographic assessment of renal artery stenosis
van Jaarsveld, B. C., Pieterman, H., van Dijk, L. C., Seijen, A. J. V., Krijnen, P., Derkx, F. H. M., Veld, A. J. M. I., & Schalekamp, M. A. D. H. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917120-00010 · Cited by 77
Cited by
ESC Guidelines on the diagnosis and treatment of peripheral artery diseases
Endorsed by: the European Stroke Organisation (ESO), Authors/Task Force Members, Tendera, M., Aboyans, V., Bartelink, M.-L., Baumgartner, I., Clément, D., Collet, J.-P., Cremonesi, A., De Carlo, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr211 · Cited by 1,506
Leung, A. A., Daskalopoulou, S. S., Dasgupta, K., McBrien, K., Butalia, S., Zarnke, K. B., Nerenberg, K., Harris, K. C., Nakhla, M., Cloutier, L., et al. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.03.005 · Cited by 318
Renovascular Hypertension and Ischemic Nephropathy
Garovic, V. D., & Textor, S. C. (2005) · Circulation · doi:10.1161/circulationaha.104.492348 · Cited by 296
Renovascular hypertension in children
Tullus, K., Brennan, E., Hamilton, G., Lord, R., McLaren, C. A., Marks, S. D., & Roebuck, D. J. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60626-1 · Cited by 285
Trinquart, L., Mounier-Vehier, C., Sapoval, M., Gagnon, N., & Plouin, P.-F. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.152918 · Cited by 268
Metadata
- Authors
- Vasbinder, G. B. C., Nelemans, P. J., Kessels, A. G. H., Kroon, A. A., Maki, J. H., Leiner, T., Beek, F. J. A., Korst, M. B. J. M., Flobbe, K., de Haan, M. W., van Zwam, W. H., Postma, C. T., Hunink, M. G. M., de Leeuw, P. W., van Engelshoven, J. M. A., & for the Renal Artery Diagnostic Imaging Study in Hypertension (RADISH) Study Group*
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2004-11-02
- Volume
- 141
- Issue
- 9
- Pages
- 674-682
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2120845100
- Cited by
- 365
- References
- 14
- FWCI
- 25.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Computed Tomographic Angiography and Magnetic Resonance Angiography for Diagnosing Renal Artery Stenosis. https://app.cochat.ai/papers/10.7326/0003-4819-141-9-200411020-00007
- The paper
- Vasbinder, G. B. C., Nelemans, P. J., Kessels, A. G. H., Kroon, A. A., Maki, J. H., Leiner, T., Beek, F. J. A., Korst, M. B. J. M., Flobbe, K., de Haan, M. W., van Zwam, W. H., Postma, C. T., Hunink, M. G. M., de Leeuw, P. W., van Engelshoven, J. M. A., & for the Renal Artery Diagnostic Imaging Study in Hypertension (RADISH) Study Group*. (2004). Accuracy of Computed Tomographic Angiography and Magnetic Resonance Angiography for Diagnosing Renal Artery Stenosis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-141-9-200411020-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.