Meta-Analysis: Methods for Diagnosing Intravascular Device–Related Bloodstream Infection
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
BACKGROUND: No consensus exists on the best methods for diagnosis of intravascular device (IVD)-related bloodstream infection. PURPOSE: To identify the most accurate methods for diagnosis of IVD-related bloodstream infection. DATA SOURCES: 51 English-language studies published from 1966 to 31 July 2004. STUDY SELECTION: Studies of diagnostic tests for IVD-related bloodstream infection that described a reference standard and provided sufficient data to calculate sensitivity and specificity. DATA EXTRACTION: Study quality, diagnostic tests examined, patient characteristics, prevalence, sensitivity, and specificity. DATA SYNTHESIS: Pooled sensitivity and specificity were calculated for 8 diagnostic methods. Summary measures of accuracy were Q* (the upper leftmost point on the summary receiver-operating characteristic curve) and mean D (a log odds ratio). Subgroup analyses were used to assess heterogeneity. Overall, the most accurate test was paired quantitative blood culture (Q* = 0.94 [95% CI, 0.88 to 1.0]), followed by IVD-drawn quantitative [corrected] blood culture (Q* = 0.89 [CI, 0.79 to 0.99]) and the acridine orange leukocyte cytospin test (Q* = 0.89 [CI, 0.79 to 0.91]). The most accurate catheter segment culture test was quantitative culture (Q* = 0.87 [CI, 0.81 to 0.93]), followed by semi-quantitative culture (Q* = 0.84 [CI, 0.80 to 0.88]). Significant heterogeneity in pooled sensitivity and specificity was observed across all test categories. LIMITATIONS: The limited number of studies of some of the diagnostic methods precludes precise estimates of accuracy. CONCLUSIONS: Paired quantitative blood culture is the most accurate test for diagnosis of IVD-related bloodstream infection. However, most other methods studied showed acceptable sensitivity and specificity (both >0.75) and negative predictive value (>99%). The positive predictive value of all tests increased greatly with high pretest clinical probability. Catheters should not be cultured routinely but rather only if IVD-related bloodstream infection is suspected clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Self-citationGuidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Pittet, D. (1994) · JAMA · doi:10.1001/jama.1994.03510440058033 · Cited by 926
Prevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919
Secular trends in nosocomial primary bloodstream infections in the United States, 1980–1989.
Banerjee, S. N., Emori, T. G., Culver, D. H., Gaynes, R. P., Jarvis, W. R., Horan, T., Edwards, J. R., Tolson, J., Henderson, T., Martone, W. J., et al. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90349-3 · Cited by 880
Cited by
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“Overall, quantitative blood cultures are the most accurate method by which to diagnose CRBSI [34, 35].”
BackgroundMethodFreifeld, A. G., Bow, E. J., Sepkowitz, K. A., Boeckh, M. J., Ito, J. I., Mullen, C. A., Raad, I. I., Rolston, K. V., Young, J.-A. H., & Wingard, J. R. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir073 · Cited by 3,463
Coagulase-Negative Staphylococci
Becker, K., Heilmann, C., & Peters, G. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00109-13 · Cited by 1,628
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Self-citationTime Lines of Infection and Disease in Human Influenza: A Review of Volunteer Challenge Studies
Carrat, F., Vergu, E., Ferguson, N. M., Lemaitre, M., Cauchemez, S., Leach, S., & Valleron, A.-J. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm375 · Cited by 1,133
ESCMID∗ guideline for the diagnosis and treatment of biofilm infections 2014
Høiby, N., Bjarnsholt, T., Moser, C., Bassi, G. L., Coenye, T., Donelli, G., Hall-Stoodley, L., Holá, V., Imbert, C., Kirketerp-Møller, K., et al. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2014.10.024 · Cited by 726
Freifeld, A. G., Bow, E. J., Sepkowitz, K. A., Boeckh, M. J., Ito, J. I., Mullen, C. A., Raad, I. I., Rolston, K. V., Young, J.-A. H., & Wingard, J. R. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/ciq147 · Cited by 704
Miller, J. M., Binnicker, M. J., Campbell, S., Carroll, K. C., Chapin, K. C., Gilligan, P. H., Gonzalez, M. D., Jerris, R. C., Kehl, S. C., Patel, R., et al. (2018) · Clinical Infectious Diseases · doi:10.1093/cid/ciy381 · Cited by 641
Infusion Nursing Standards of Practice
Gorski, L. A. (2007) · Journal of Infusion Nursing · doi:10.1097/01.nan.0000270673.13439.95 · Cited by 602
O’Grady, N. P., Barie, P. S., Bartlett, J. G., Bleck, T., Carroll, K., Kalil, A. C., Linden, P., Maki, D. G., Nierman, D., Pasculle, W., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318169eda9 · Cited by 600
Self-citationBaron, E. J., Miller, J. M., Weinstein, M. P., Richter, S. S., Gilligan, P. H., Thomson, R. B., Bourbeau, P., Carroll, K. C., Kehl, S. C., Dunne, W. M., et al. (2013) · Clinical Infectious Diseases · doi:10.1093/cid/cit278 · Cited by 592
Intravascular catheter-related infections: advances in diagnosis, prevention, and management
Raad, I., Hanna, H., & Maki, D. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70235-9 · Cited by 525
Self-citationSlobbe, L., Doorduijn, J. K., Lugtenburg, P. J., el Barzouhi, A., Boersma, E., van Leeuwen, W. B., & Rijnders, B. J. A. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010840 · Cited by 490
Miller, J. M., Binnicker, M. J., Campbell, S., Carroll, K. C., Chapin, K. C., Gilligan, P. H., Gonzalez, M. D., Jerris, R. C., Kehl, S. C., Patel, R., et al. (2018) · Clinical Infectious Diseases · doi:10.1093/cid/ciy584 · Cited by 449
Coagulase-Negative Staphylococcal Infections
Rogers, K. L., Fey, P. D., & Rupp, M. E. (2009) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2008.10.001 · Cited by 401
Miller, J. M., Binnicker, M. J., Campbell, S., Carroll, K. C., Chapin, K. C., Gonzalez, M. D., Harrington, A., Jerris, R. C., Kehl, S. C., Leal, S. M., et al. (2024) · Clinical Infectious Diseases · doi:10.1093/cid/ciae104 · Cited by 376
Vascular access for hemodialysis: current perspectives
Santoro, D., Benedetto, F., Mondello, P., Spinelli, F., Ricciardi, C., Cernaro, V., Buemi, M., Pipito', N., & Barilla', D. (2014) · International Journal of Nephrology and Renovascular Disease · doi:10.2147/ijnrd.s46643 · Cited by 365
Towards diagnostic guidelines for biofilm-associated infections
Hall-Stoodley, L., Stoodley, P., Kathju, S., Høiby, N., Moser, C., William Costerton, J., Moter, A., & Bjarnsholt, T. (2012) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2012.00968.x · Cited by 357
The Role of Bacterial Biofilms in Device-Associated Infection
Deva, A. K., Adams, W. P., & Vickery, K. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a3c105 · Cited by 258
Sepsis: mechanisms of bacterial injury to the patient
Minasyan, H. (2019) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/s13049-019-0596-4 · Cited by 215
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Empirical evidence of the importance of comparative studies of diagnostic test accuracy
Takwoingi, Y., Leeflang, M. M. G., & Deeks, J. J. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-7-201304020-00006 · Cited by 187
Bouza, E., Alvarado, N., Alcala, L., Perez, M. J., Rincon, C., & Munoz, P. (2007) · Clinical Infectious Diseases · doi:10.1086/511865 · Cited by 179
“[48] concluded that paired quantitative blood cultures were the most accurate test for the diagnosis of CR-BSI.”
BackgroundChaves, F., Garnacho-Montero, J., del Pozo, J. L., Bouza, E., Capdevila, J. A., de Cueto, M., Domínguez, M. Á., Esteban, J., Fernández-Hidalgo, N., Fernández Sampedro, M., et al. (2018) · Medicina Intensiva · doi:10.1016/j.medin.2017.09.012 · Cited by 170
“70 In the meta-analysis by Safdar et al., 62 the overall sensitivity and specificity of the AOLC test were 72% and 91%, respectively.”
InfluentialVanholder, R., Canaud, B., Fluck, R., Jadoul, M., Labriola, L., Marti-Monros, A., Tordoir, J., & Van Biesen, W. (2010) · Clinical Kidney Journal · doi:10.1093/ndtplus/sfq041 · Cited by 124
“Usefulness of DTP criteria in samples from two catheter lumens has not been clarified [65–67] (17)(18)(19).”
Background
Metadata
- Authors
- Safdar, N., Fine, J. P., & Maki, D. G.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2005-03-15
- Volume
- 142
- Issue
- 6
- Pages
- 451-466
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2039825164
- Cited by
- 329
- References
- 65
- FWCI
- 32.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.