CoChat

A Red Blood Cell Agglutination d-Dimer Test to Exclude Deep Venous Thrombosis in Pregnancy

Chan, Wee-Shian, Chunilal, Sanjeev, Lee, Agnes, Crowther, Mark, Rodger, Marc, Ginsberg, Jeffrey S. · 2007 · Annals of Internal Medicine
Cited by 134

The DOI matches its Crossref record.

Abstract

BACKGROUND: D-Dimer testing is often used with compression ultrasonography for the diagnosis of deep venous thrombosis (DVT) in nonpregnant patients. The D-dimer test is highly sensitive, and a negative result can obviate the need for further testing for DVT. This test has not been studied for DVT diagnosis in pregnancy because its specificity was deemed too poor. OBJECTIVE: To determine the sensitivity and specificity and assess the utility of the SimpliRED assay (Agen Biomedical, Brisbane, Australia) for the diagnosis of DVT in pregnant women. DESIGN: Prospective cohort study. SETTING: 5 tertiary university-affiliated Canadian hospitals providing care to obstetric patients. PATIENTS: 149 consecutive pregnant women with suspected DVT who presented to 1 of the participating centers over 5 years. INTERVENTION: Participating women were tested with compression leg ultrasonography (single or serially on days 0, 3, and 7) and received 3 months' clinical follow-up for the presence or absence of DVT. Whole blood was tested with the SimpliRED assay at initial presentation, and results were correlated with ultrasonography and clinical findings for the presence or absence of DVT. MEASUREMENTS: The sensitivity, specificity, and negative predictive value of the SimpliRED assay were calculated, along with the prevalence of false-positive SimpliRED assay results (with 95% CIs). RESULTS: The prevalence of DVT in the cohort was 8.7% (95% CI, 5.2% to 14.4%). The sensitivity of the SimpliRED assay was 100% (CI, 77% to 100% [13 of 13 patients]), the specificity was 60% (CI, 52% to 68% [81 of 135]), and the negative predictive value was 100% (CI, 95% to 100% [81 of 81]). The SimpliRED assay was positive in 0% (CI, 0% to 60%), 24% (CI, 14% to 37%), and 51% (CI, 40% to 61%) of women in the first, second, and third trimesters, respectively, among pregnant patients in whom DVT was not diagnosed. LIMITATIONS: The prevalence of DVT in the cohort was low, resulting in wide CIs. The clinician's previous impression was used to determine pretest probability in the absence of a validated clinical prediction rule for pregnant women. CONCLUSION: The SimpliRED assay may be useful in pregnancy because a normal result excludes DVT and occurs frequently enough to be clinically helpful.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-147-3-200708070-00005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 134

Metadata

Authors
Chan, W.-S., Chunilal, S., Lee, A., Crowther, M., Rodger, M., & Ginsberg, J. S.
Venue
Annals of Internal Medicine
Published
2007-08-07
Volume
147
Issue
3
Pages
165-170
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2067855848
Cited by
134
References
0
FWCI
7.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Red Blood Cell Agglutination d-Dimer Test to Exclude Deep Venous Thrombosis in Pregnancy. https://app.cochat.ai/papers/10.7326/0003-4819-147-3-200708070-00005
The paper
Chan, W.-S., Chunilal, S., Lee, A., Crowther, M., Rodger, M., & Ginsberg, J. S. (2007). A Red Blood Cell Agglutination d-Dimer Test to Exclude Deep Venous Thrombosis in Pregnancy. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-147-3-200708070-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.