Accuracy of Serologic Tests and HLA-DQ Typing for Diagnosing Celiac Disease

Hadithi, Muhammed, von Blomberg, B. Mary E., Crusius, J. Bart A., Bloemena, Elisabeth, Kostense, Pieter J., Meijer, Jos W.R., Mulder, Chris J.J., Stehouwer, Coen D.A., Peña, Amado S. · 2007 · Annals of Internal Medicine

Abstract

BACKGROUND: Estimates of the diagnostic performance of serologic testing and HLA-DQ typing for detecting celiac disease have mainly come from case-control studies. OBJECTIVE: To define the performance of serologic testing and HLA-DQ typing prospectively. DESIGN: Prospective cohort study. SETTING: University hospital. PATIENTS: Patients referred for small-bowel biopsy for the diagnosis of celiac disease. INTERVENTIONS: Celiac serologic testing (antigliadin antibodies [AGA], antitransglutaminase antibodies [TGA], and antiendomysium antibodies [EMA]) and HLA-DQ typing. MEASUREMENTS: Diagnostic performance of serologic testing and HLA-DQ typing compared with a reference standard of abnormal histologic findings and clinical resolution after a gluten-free diet. RESULTS: Sixteen of 463 participants had celiac disease (prevalence, 3.46% [95% CI, 1.99% to 5.55%]). A positive result on both TGA and EMA testing had a sensitivity of 81% (CI, 54% to 95.9%), specificity of 99.3% (CI, 98.0% to 99.9%), and negative predictive value of 99.3% (CI, 98.0% to 99.9%). Testing positive for either HLA-DQ type maximized sensitivity (100% [CI, 79% to 100%]) and negative predictive value (100% [CI, 98.6% to 100%]), whereas testing negative for both minimized the negative likelihood ratio (0.00 [CI, 0.00 to 0.40]) and posttest probability (0% [CI, 0% to 1.4%]). The addition of HLA-DQ typing to TGA and EMA testing, and the addition of serologic testing to HLA-DQ typing, did not change test performance compared with either testing strategy alone. LIMITATION: Few cases of celiac disease precluded meaningful comparisons of testing strategies. CONCLUSIONS: In a patient population referred for symptoms and signs of celiac disease with a prevalence of celiac disease of 3.46%, TGA and EMA testing were the most sensitive serum antibody tests and a negative HLA-DQ type excluded the diagnosis. However, the addition of HLA-DQ typing to TGA and EMA testing, and the addition of serologic testing to HLA-DQ typing, provided the same measures of test performance as either testing strategy alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-147-5-200709040-00003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 214

Metadata

Authors
Hadithi, M., von Blomberg, B. M. E., Crusius, J. B. A., Bloemena, E., Kostense, P. J., Meijer, J. W. R., Mulder, C. J. J., Stehouwer, C. D. A., & Peña, A. S.
Venue
Annals of Internal Medicine
Published
2007-09-04
Volume
147
Issue
5
Pages
294-302
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2080525752
Cited by
214
References
2
FWCI
10.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Serologic Tests and HLA-DQ Typing for Diagnosing Celiac Disease. https://app.cochat.ai/papers/10.7326/0003-4819-147-5-200709040-00003
The paper
Hadithi, M., von Blomberg, B. M. E., Crusius, J. B. A., Bloemena, E., Kostense, P. J., Meijer, J. W. R., Mulder, C. J. J., Stehouwer, C. D. A., & Peña, A. S. (2007). Accuracy of Serologic Tests and HLA-DQ Typing for Diagnosing Celiac Disease. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-147-5-200709040-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.