When Should a New Test Become the Current Reference Standard?
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The evaluation of claims that a new diagnostic test is better than the current gold standard test is hindered by the lack of a perfect reference judge. However, this problem may be sidestepped by focusing on the clinical consequences of the decision rather than on estimation of accuracy. Consequences can be assessed by use of a "fair umpire" test that is not perfect yet can discriminate between disease and nondisease cases and is not biased in favor of 1 test. This article discusses 3 principles to aid judgments about the value of new tests. First, the consequences are best examined in cases with disagreement between the current and new tests. Second, resolving these disagreements requires a fair, but not necessarily perfect, umpire test. Finally, umpire tests include consequences, such as prognosis and response to treatment, as well as causal exposures and other test results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“We should begin with an examination of any known flaws in the current reference test (19) to see whether these might explain the differences.”
BackgroundEvaluation of diagnostic tests when there is no gold standard. A review of methods
Rutjes, A., Reitsma, J., Coomarasamy, A., Khan, K., & Bossuyt, P. (2007) · Health Technology Assessment · doi:10.3310/hta11500 · Cited by 524 · cited 1×
“Most previous work on this topic has considered the problem of estimating the accuracy of the new test (7) by using such methods as combined tests (using several tests as the reference standard) or discrepant analysis (8–10) (use of a third test to resolve disagreements between the 2 tests).”
MethodSanders, D. S., Carter, M. J., Hurlstone, D. P., Pearce, A., Ward, A. M., McAlindon, M. E., & Lobo, A. J. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06581-3 · Cited by 390
Ramers, C. (2000) · JAMA · doi:10.1001/jama.283.20.2680 · Cited by 291 · cited 1×
“This problem is not unique to multiple sclerosis; new enzyme tests, such as troponins (2); DNA methods in microbiology, such as polymerase chain reaction tests (3); new cardiac hormone tests, such as Btype natriuretic peptide for heart failure (4); and new imaging methods, such as magnetic resonance imaging and positr…”
Background
Cited by
Statistical Evaluation of a Biomarker
Ray, P., Manach, Y. L., Riou, B., Houle, T. T., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d47604 · Cited by 503
Shah, A. S. V., Griffiths, M., Lee, K. K., McAllister, D. A., Hunter, A. L., Ferry, A. V., Cruikshank, A., Reid, A., Stoddart, M., Strachan, F., et al. (2015) · BMJ · doi:10.1136/bmj.g7873 · Cited by 450
Computed Tomography Aortic Valve Calcium Scoring in Patients With Aortic Stenosis
Pawade, T., Clavel, M.-A., Tribouilloy, C., Dreyfus, J., Mathieu, T., Tastet, L., Renard, C., Gun, M., Jenkins, W. S. A., Macron, L., et al. (2018) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.007146 · Cited by 397
“This has led to great interest in using CT-AVC as an alternative assessment of AS severity and as an umpire test in patients with discordant echocardiographic findings.(14) Although CT calcium scoring has recently been recommended in the latest European Society of Cardiology guidelines (for patients with low flow and…”
MethodClinical implications of discordance between low-density lipoprotein cholesterol and particle number
Otvos, J. D., Mora, S., Shalaurova, I., Greenland, P., Mackey, R. H., & Goff, D. C. (2011) · Journal of Clinical Lipidology · doi:10.1016/j.jacl.2011.02.001 · Cited by 384
Thompson, M., Van den Bruel, A., Verbakel, J., Lakhanpaul, M., Haj-Hassan, T., Stevens, R., Moll, H., Buntinx, F., Berger, M., Aertgeerts, B., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16150 · Cited by 324
Metadata
- Authors
- Glasziou, P., Irwig, L., & Deeks, J. J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2008-12-02
- Volume
- 149
- Issue
- 11
- Pages
- 816-821
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2050552569
- Cited by
- 97
- References
- 4
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: When Should a New Test Become the Current Reference Standard? https://app.cochat.ai/papers/10.7326/0003-4819-149-11-200812020-00009
- The paper
- Glasziou, P., Irwig, L., & Deeks, J. J. (2008). When Should a New Test Become the Current Reference Standard? Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-149-11-200812020-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.