Meta-analysis: Noninvasive Coronary Angiography Using Computed Tomography Versus Magnetic Resonance Imaging
The DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Two imaging techniques, multislice computed tomography (CT) and magnetic resonance imaging (MRI), have evolved for noninvasive coronary angiography. PURPOSE: To compare CT and MRI for ruling out clinically significant coronary artery disease (CAD) in adults with suspected or known CAD. DATA SOURCES: MEDLINE, EMBASE, and ISI Web of Science searches from inception through 2 June 2009 and bibliographies of reviews. STUDY SELECTION: Prospective English- or German-language studies that compared CT or MRI with conventional coronary angiography in all patients and included sufficient data for compilation of 2 x 2 tables. DATA EXTRACTION: 2 investigators independently extracted patient and study characteristics; differences were resolved by consensus. DATA SYNTHESIS: 89 and 20 studies (comprising 7516 and 989 patients) assessed CT and MRI, respectively. Bivariate analysis of data yielded a mean sensitivity and specificity of 97.2% (95% CI, 96.2% to 98.0%) and 87.4% (CI, 84.5% to 89.8%) for CT and 87.1% (CI, 83.0% to 90.3%) and 70.3% (CI, 58.8% to 79.7%) for MRI. In studies that included only patients with suspected CAD, sensitivity and specificity of CT were 97.6% (CI, 96.1% to 98.5%) and 89.2% (CI, 86.0% to 91.8%). Covariate analysis yielded a significantly higher sensitivity for CT scanners with more than 16 rows (98.1% [CI, 97.0% to 99.0%]; P < 0.050) than for older-generation scanners (95.6% [CI, 94.0% to 97.0%]). Heart rates less than 60 beats/min during CT yielded significantly better values for sensitivity than did higher heart rates (P < 0.001). LIMITATIONS: Few studies investigated coronary angiography with MRI. Only 5 studies were direct head-to-head comparisons of CT and MRI. Covariate analyses explained only part of the observed heterogeneity. CONCLUSION: For ruling out CAD, CT is more accurate than MRI. Scanners with more than 16 rows improve sensitivity, as do slowed heart rates. PRIMARY FUNDING SOURCE: None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Writing Group Members, Rosamond, W., Flegal, K., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S. M., Ho, M., Howard, V., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.187998 · Cited by 3,711
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Budoff, M. J., Dowe, D., Jollis, J. G., Gitter, M., Sutherland, J., Halamert, E., Scherer, M., Bellinger, R., Martin, A., Benton, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.031 · Cited by 2,125
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Self-citationAdvanced methods in meta‐analysis: multivariate approach and meta‐regression
van Houwelingen, H. C., Arends, L. R., & Stijnen, T. (2002) · Statistics in Medicine · doi:10.1002/sim.1040 · Cited by 1,580
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
Meijboom, W. B., Meijs, M. F. L., Schuijf, J. D., Cramer, M. J., Mollet, N. R., van Mieghem, C. A. G., Nieman, K., van Werkhoven, J. M., Pundziute, G., Weustink, A. C., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.058 · Cited by 1,239
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Bellenger, N. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2011 · Cited by 1,040
Language bias in randomised controlled trials published in English and German
Egger, M., Zellweger-Zähner, T., Schneider, M., Junker, C., Lengeler, C., & Antes, G. (1997) · The Lancet · doi:10.1016/s0140-6736(97)02419-7 · Cited by 1,028
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Chu, H., & Cole, S. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.06.011 · Cited by 708
Schwitter, J., Wacker, C. M., van Rossum, A. C., Lombardi, M., Al-Saadi, N., Ahlstrom, H., Dill, T., Larsson, H. B. W., Flamm, S. D., Marquardt, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm617 · Cited by 672
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Hamon, M., Biondi-Zoccai, G. G. L., Malagutti, P., Agostoni, P., Morello, R., Valgimigli, M., & Hamon, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.028 · Cited by 460
Vanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M. (2007) · Radiology · doi:10.1148/radiol.2442061218 · Cited by 442
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Circulation · doi:10.1161/01.cir.99.17.2345 · Cited by 433
Scheffel, H., Alkadhi, H., Plass, A., Vachenauer, R., Desbiolles, L., Gaemperli, O., Schepis, T., Frauenfelder, T., Schertler, T., Husmann, L., et al. (2006) · European Radiology · doi:10.1007/s00330-006-0474-0 · Cited by 420
Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S. (2004) · Circulation · doi:10.1161/01.cir.0000145614.07427.9f · Cited by 413
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Noto, T. J., Johnson, L. W., Krone, R., Weaver, W. F., Clark, D. A., Kramer, J. R., Vetrovec, G. W., & Parker, J. J. (1991) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810240202 · Cited by 390
Abdulla, J., Abildstrom, S. Z., Gotzsche, O., Christensen, E., Kober, L., & Torp-Pedersen, C. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm466 · Cited by 357
No role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009) · Circulation · doi:10.1161/circulationaha.109.859280 · Cited by 328
Self-citationA bivariate approach to meta-analysis
Van Houwelingen, H. C., Zwinderman, K. H., & Stijnen, T. (1993) · Statistics in Medicine · doi:10.1002/sim.4780122405 · Cited by 327 · cited 1×
“For data analysis, we used an exact binomial rendition (12) of the bivariate mixed-effects regression model developed by Van Houwelingen and colleagues for treatment trial meta-analysis (13, 14), modified for synthesis of diagnostic test data (15, 16).”
MethodLeber, A. W., Johnson, T. R. C., Becker, A., von Ziegler, F., Tittus, J., Nikolaou, K., Reiser, M., Steinbeck, G., Becker, C. R., & Knez, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm294 · Cited by 306
Accuracy of 16-Row Multidetector Computed Tomography for the Assessment of Coronary Artery Stenosis
Garcia, M. J., Lessick, J., Hoffmann, M. H. K., & CATSCAN Study Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.4.403 · Cited by 301
Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
Scheffel, H., Alkadhi, H., Leschka, S., Plass, A., Desbiolles, L., Guber, I., Krauss, T., Gruenenfelder, J., Genoni, M., Luescher, T. F., et al. (2008) · Heart · doi:10.1136/hrt.2008.149971 · Cited by 291
Detection of Coronary Artery Stenosis With Whole-Heart Coronary Magnetic Resonance Angiography
Sakuma, H., Ichikawa, Y., Chino, S., Hirano, T., Makino, K., & Takeda, K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.055 · Cited by 275
Claustrophobia during magnetic resonance imaging: Cohort study in over 55,000 patients
Dewey, M., Schink, T., & Dewey, C. F. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21147 · Cited by 270
Self-citationLord, S. J., Irwig, L., & Simes, R. J. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-11-200606060-00011 · Cited by 268
Mowatt, G., Cummins, E., Waugh, N., Walker, S., Cook, J., Jia, X., Hillis, G., & Fraser, C. (2008) · Health Technology Assessment · doi:10.3310/hta12170 · Cited by 261
Accuracy of thin-slice computed tomography in the detection of coronary stenoses
MARTUSCELLI, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.024 · Cited by 259
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
Achenbach, S., Marwan, M., Schepis, T., Pflederer, T., Bruder, H., Allmendinger, T., Petersilka, M., Anders, K., Lell, M., Kuettner, A., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.02.008 · Cited by 258
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Meijboom, W. B., Mollet, N. R., Van Mieghem, C. A. G., Kluin, J., Weustink, A. C., Pugliese, F., Vourvouri, E., Cademartiri, F., Bogers, A. J. J. C., Krestin, G. P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.054 · Cited by 249
Bivariate random-effects meta-analysis and the estimation of between-study correlation
Riley, R. D., Abrams, K. R., Sutton, A. J., Lambert, P. C., & Thompson, J. R. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-3 · Cited by 244
Brodoefel, H., Burgstahler, C., Tsiflikas, I., Reimann, A., Schroeder, S., Claussen, C. D., Heuschmid, M., & Kopp, A. F. (2008) · Radiology · doi:10.1148/radiol.2472070906 · Cited by 243
Hamon, M., Morello, R., Riddell, J. W., & Hamon, M. (2007) · Radiology · doi:10.1148/radiol.2453061899 · Cited by 241
Schuijf, J. D., Pundziute, G., Jukema, J. W., Lamb, H. J., van der Hoeven, B. L., de Roos, A., van der Wall, E. E., & Bax, J. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.092 · Cited by 232
Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3.0-T
Yang, Q., Li, K., Liu, X., Bi, X., Liu, Z., An, J., Zhang, A., Jerec̆ić, R., & Li, D. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.016 · Cited by 201
Noninvasive Evaluation With Multislice Computed Tomography in Suspected Acute Coronary Syndrome
Henneman, M. M., Schuijf, J. D., Pundziute, G., van Werkhoven, J. M., van der Wall, E. E., Jukema, J. W., & Bax, J. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.012 · Cited by 189
Alkadhi, H., Scheffel, H., Desbiolles, L., Gaemperli, O., Stolzmann, P., Plass, A., Goerres, G. W., Luescher, T. F., Genoni, M., Marincek, B., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn044 · Cited by 182
Maruyama, T., Takada, M., Hasuike, T., Yoshikawa, A., Namimatsu, E., & Yoshizumi, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.048 · Cited by 175
Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi326 · Cited by 172
Dewey, M., Teige, F., Schnapauff, D., Laule, M., Borges, A. C., Wernecke, K., Schink, T., Baumann, G., Rutsch, W. R., Rogalla, P., et al. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-6-200609190-00004 · Cited by 168
Self-citationMultidetector Computed Tomography for the Diagnosis of Coronary Artery Disease: A Systematic Review
Stein, P. D., Beemath, A., Kayali, F., Skaf, E., Sánchez, J., & Olson, R. E. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.06.071 · Cited by 164
Janne d’Othée, B., Siebert, U., Cury, R., Jadvar, H., Dunn, E. J., & Hoffmann, U. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.05.003 · Cited by 161
Gilard, M., Cornily, J., Pennec, P.-Y., Joret, C., Gal, G. L., Mansourati, J., Blanc, J., & Boschat, J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.085 · Cited by 148
Reliable High-Speed Coronary Computed Tomography in Symptomatic Patients
Weustink, A. C., Meijboom, W. B., Mollet, N. R., Otsuka, M., Pugliese, F., van Mieghem, C. A. G., Malagò, R., van Pelt, N., Dijkshoorn, M. L., Cademartiri, F., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.068 · Cited by 147
Kefer, J., Coche, E., Legros, G., Pasquet, A., Grandin, C. B. G., BEERS, B. E. V., Vanoverschelde, J., & Gerber, B. L. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.057 · Cited by 144
Sun, Z., & Jiang, W. J. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.009 · Cited by 138
Hausleiter, J., Meyer, T., Hadamitzky, M., Zankl, M., Gerein, P., Dorrler, K., Kastrati, A., Martinoff, S., & Schomig, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm150 · Cited by 138
Andreini, D., Pontone, G., Pepi, M., Ballerini, G., Bartorelli, A. L., Magini, A., Quaglia, C., Nobili, E., & Agostoni, P. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.086 · Cited by 135
Herzog, B. A., Husmann, L., Burkhard, N., Gaemperli, O., Valenta, I., Tatsugami, F., Wyss, C. A., Landmesser, U., & Kaufmann, P. A. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn485 · Cited by 128
Ghostine, S., Caussin, C., Daoud, B., Habis, M., Perrier, E., Pesenti-Rossi, D., Sigal-Cinqualbre, A. B., Angel, C.-Y., Lancelin, B., Capderou, A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.103 · Cited by 127
Regenfus, M., Ropers, D., Achenbach, S. S., Kessler, W., Laub, G. A., Daniel, W. G., & Moshage, W. E. L. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00672-0 · Cited by 126
Dewey, M., & Hamm, B. (2006) · European Radiology · doi:10.1007/s00330-006-0439-3 · Cited by 123
Self-citationÖncel, D., Öncel, G., & Taştan, A. (2007) · Radiology · doi:10.1148/radiol.2453070094 · Cited by 123
Plein, S., Kozerke, S., Sürder, D., Lüscher, T. F., Greenwood, J. P., Boesiger, P., & Schwitter, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn297 · Cited by 123
Original Paper: A likelihood ratio approach to meta-analysis of diagnostic studies
Stengel, D., Bauwens, K., Sehouli, J., Ekkernkamp, A., & Porzsolt, F. (2003) · Journal of Medical Screening · doi:10.1258/096914103321610806 · Cited by 118
64-Slice CT coronary angiography in patients with non-ST elevation acute coronary syndrome
Meijboom, W. B., Mollet, N. R., van Mieghem, C. A. G., Weustink, A. C., Pugliese, F., van Pelt, N., Cademartiri, F., Vourvouri, E. C., de Jaegere, P. P. T., Krestin, G. P., et al. (2007) · Heart · doi:10.1136/hrt.2006.112771 · Cited by 118
Herzog, C., Zwerner, P. L., Doll, J. R., Nielsen, C. D., Nguyen, S. A., Savino, G., Vogl, T. J., Costello, P., & Schoepf, U. J. (2007) · Radiology · doi:10.1148/radiol.2441060332 · Cited by 115
Highly accurate coronary angiography with submillimetre, 16 slice computed tomography
Morgan-Hughes, G. J., Roobottom, C. A., Owens, P. E., & Marshall, A. J. (2005) · Heart · doi:10.1136/hrt.2004.034892 · Cited by 96
Quantification of Right and Left Ventricular Function by Cardiovascular Magnetic Resonance
Bellenger, N. G., Grothues, F., Smith, G. C., & Pennell, D. J. (2000) · Herz · doi:10.1007/s000590050031 · Cited by 91
Réant, P., Brunot, S., Lafitte, S., Serri, K., Leroux, L., Corneloup, O., Iriart, X., Coste, P., Santos, P. D. D., Roudaut, R., et al. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.12.039 · Cited by 89
Scheffel, H., Leschka, S., Plass, A., Vachenauer, R., Gaemperli, O., Garzoli, E., Genoni, M., Marinček, B., Kaufmann, P. A., & Alkadhi, H. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.03.087 · Cited by 89
Laissy, J., Messika–Zeitoun, D., Serfaty, J., Sebban, V., Schouman‐Claeys, E., Iung, B., & Vahanian, A. S. (2007) · Heart · doi:10.1136/hrt.2006.107284 · Cited by 88
Leschka, S., Scheffel, H., Desbiolles, L., Plass, A., Gaemperli, O., Stolzmann, P., Genoni, M., Lüscher, T. F., Marinček, B., Kaufmann, P. A., et al. (2007) · Heart · doi:10.1136/hrt.2007.124800 · Cited by 83
Klein, C., Gebker, R., Kokocinski, T., Dreysse, S. T., Schnackenburg, B., Fleck, E., & Nagel, E. C. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-45 · Cited by 71
Danias, P. G., Roussakis, A., & Ioannidis, J. P. A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.07.051 · Cited by 70
NIMISCAD Study Group, Marano, R., COBELLI, F. D., Floriani, I., Becker, C. R., Herzog, C., Centonze, M., Morana, G., Gualdi, G. F., Ligabue, G., et al. (2008) · European Radiology · doi:10.1007/s00330-008-1239-8 · Cited by 69
Pundziūtė, G., Schuijf, J. D., Jukema, J. W., van Werkhoven, J. M., Boersma, E. H., Roos, A., van der Wall, E. E., & Bax, J. J. (2007) · Heart · doi:10.1136/hrt.2007.116715 · Cited by 65
Henneman, M. M., Schuijf, J. D., Jukema, J. W., Lamb, H. J., Roos, A., Dibbets, P., Stokkel, M. P. M., van der Wall, E. E., & Bax, J. J. (2006) · Heart · doi:10.1136/hrt.2006.087874 · Cited by 55
Multislice Computed Tomography in an Asymptomatic High-Risk Population
Romeo, F., Leo, R., Clementi, F., Razzini, C., Borzi, M., Martuscelli, E., Pizzuto, F., Chiricolo, G., & Mehta, J. L. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.08.029 · Cited by 53
Cademartiri, F., Maffei, E., Palumbo, A., Malagò, R., Alberghina, F., Aldrovandi, A., Brambilla, V., Runza, G., Grutta, L. L., Menozzi, A., et al. (2007) · La radiologia medica · doi:10.1007/s11547-007-0198-5 · Cited by 41
Cornily, J., Gilard, M., Gal, G. L., Pennec, P.-Y., Vinsonneau, U., Blanc, J., Mansourati, J., & Boschat, J. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.08.010 · Cited by 36
Vanhoenacker, P. K., Decramer, I., Bladt, O., Sarno, G., Bevernage, C., & Wijns, W. C. (2007) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-7-39 · Cited by 32
Jakobs, T., Hack, N., Nikolaou, K., Becker, C. R., von Ziegler, F., Knez, A., König, A., Klauss, V., Tiling, R., & Hacker, M. (2007) · Nuklearmedizin - NuclearMedicine · doi:10.1055/s-0037-1616623 · Cited by 31
Watkins, M. W., Hesse, B., Green, C. E., Greenberg, N. L., Manning, M., Chaudhry, E., Dauerman, H. L., & Garcia, M. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.07.081 · Cited by 29
Hacker, M., Jakobs, T., Hack, N., et al. (2007) · Cited by 24
van der Zaag–Loonen, H. J., Dikkers, R., de Bock, G. H., & Oudkerk, M. (2006) · European Radiology · doi:10.1007/s00330-006-0312-4 · Cited by 23
Gaudio, C., Mirabelli, F., Pelliccia, F., Francone, M., Tanzilli, G., Michele, S. D., Leonetti, S., Vincentis, G. D., Carbone, I., Mangieri, E., et al. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.03.091 · Cited by 20
Chow, B. J. W., Dennie, C. J., Hoffmann, U., So, D. Y. F., deKemp, R. A., Ruddy, T. D., & Beanlands, R. S. (2007) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(07)70831-0 · Cited by 17
Cardiac CT Research: Exponential Growth
Itagaki, M. W., Suh, R. D., & Goldin, J. G. (2009) · Radiology · doi:10.1148/radiol.2523081241 · Cited by 14
Bedaux, W. L. F., Hofman, M. B. M., Wielopolski, P. A., de Cock, C. C., Hoffmann, V., Oudkerk, M., de Feyter, P. J., & van Rossum, A. C. (2002) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120003953 · Cited by 14
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318223e2bd · Cited by 2,104
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
2011 ACCF/AHA Guideline for the Diagnosis and Treatment of Hypertrophic Cardiomyopathy
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.011 · Cited by 1,276
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Metadata
- Authors
- Schuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2010-02-02
- Volume
- 152
- Issue
- 3
- Pages
- 167-177
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2044767355
- Cited by
- 265
- References
- 103
- FWCI
- 30.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.