The Patient-Centered Medical Home, Electronic Health Records, and Quality of Care
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The patient-centered medical home (PCMH) model of primary care is being implemented widely, although its effects on quality are unclear. The PCMH typically involves electronic health records (EHRs), organizational practice change, and payment reform. OBJECTIVE: To compare quality of care provided by physicians in PCMHs with that provided by physicians using paper medical records and, separately, with that provided by physicians using EHRs without the PCMH (to determine whether effects were driven by EHRs). DESIGN: Prospective cohort study (2008 to 2010). (ClinicalTrials.gov: NCT00793065). SETTING: The Hudson Valley, a 7-county, multipayer, multiprovider region in New York. PARTICIPANTS: 675 primary care physicians in 312 practices and 143,489 patients. MEASUREMENTS: Claims for 10 quality measures from the Healthcare Effectiveness Data and Information Set were used. Differences in quality were determined using generalized estimating equations adjusted for 8 physician characteristics and 4 patient characteristics. RESULTS: The PCMH group improved significantly more over time than either the paper group or the EHR group for 4 of the 10 measures (by 1 to 9 percentage points per measure): eye examinations and hemoglobin A1c testing for patients with diabetes, chlamydia screening, and colorectal cancer screening (adjusted P < 0.05 for each). The odds of overall quality improvement in the PCMH group were 7% higher than in the paper group and 6% higher than in the EHR group (adjusted P < 0.01 for each). LIMITATION: This study was observational, and the possibility of unmeasured confounders cannot be excluded. CONCLUSION: The PCMH was associated with modest quality improvement. The aspects of the PCMH that drive improvement are distinct from but may be enabled by the EHR. PRIMARY FUNDING SOURCE: The Commonwealth Fund and the New York State Department of Health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buntin, M. B., Burke, M. F., Hoaglin, M. C., & Blumenthal, D. (2011) · Health Affairs · doi:10.1377/hlthaff.2011.0178 · Cited by 1,311 · cited 2×
“Because EHRs have their own effects on quality (3, 11, 12), our secondary aim was to compare the quality of care provided by physicians in PCMHs with that provided by physicians using EHRs without a PCMH model, thereby isolating the effect of the PCMH itself.”
BackgroundMethodThe Patient-Centered Medical Home: A Systematic Review
Jackson, G. L., Powers, B. J., Chatterjee, R., Prvu Bettger, J., Kemper, A. R., Hasselblad, V., Dolor, R. J., Irvine, R. J., Heidenfelder, B. L., Kendrick, A. S., et al. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-3-201302050-00579 · Cited by 699
Reid, R. J., Coleman, K., Johnson, E. A., Fishman, P. A., Hsu, C., Soman, M. P., Trescott, C. E., Erikson, M., & Larson, E. B. (2010) · Health Affairs · doi:10.1377/hlthaff.2010.0158 · Cited by 567
Patient outcomes at 26 months in the patient-centered medical home National Demonstration Project
Jaen, C. R., Ferrer, R. L., Miller, W. L., Palmer, R. F., Wood, R., Davila, M., Stewart, E. E., Crabtree, B. F., Nutting, P. A., & Stange, K. C. (2010) · The Annals of Family Medicine · doi:10.1370/afm.1121 · Cited by 194 · cited 6×
“001 200 236 (35) 44 (23) 156 (43) 36 (31)”
BackgroundInfluentialMaeng, D. D., Graf, T. R., Davis, D. E., Tomcavage, J., & Bloom, F. J. (2012) · American Journal of Medical Quality · doi:10.1177/1062860611417421 · Cited by 64 · cited 3×
“Another study in an integrated delivery system primarily reported changes in patient outcomes, which this study did not capture (8).”
Background
Cited by
A review of PHR, EMR and EHR integration: A more personalized healthcare and public health policy
Heart, T., Ben-Assuli, O., & Shabtai, I. (2017) · Health Policy and Technology · doi:10.1016/j.hlpt.2016.08.002 · Cited by 251
Report of the AMIA EHR-2020 Task Force on the status and future direction of EHRs
Payne, T. H., Corley, S., Cullen, T. A., Gandhi, T. K., Harrington, L., Kuperman, G. J., Mattison, J. E., McCallie, D. P., McDonald, C. J., Tang, P. C., et al. (2015) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv066 · Cited by 220
“The EHR adds substantial capability to any PCMH system.(82) In the immediate future, EHRs need to support the PCMH principles of care – ie, care that: (1) is personal, continuous, and comprehensive; (2) provides teams with a shared awareness of the patient’s situation across settings and time; (3) supports a whole-per…”
BackgroundDigital health technology and diabetes management: 数字化医疗技术与糖尿病管理
Cahn, A., Akirov, A., & Raz, I. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12606 · Cited by 102
Metadata
- Authors
- Kern, L. M., Edwards, A., & Kaushal, R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2014-06-03
- Volume
- 160
- Issue
- 11
- Pages
- 741-749
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2086554904
- Cited by
- 68
- References
- 5
- FWCI
- 29.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.