The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
rsEGFP2 enables fast RESOLFT nanoscopy of living cells
Open accessAbstract
The super-resolution microscopy called RESOLFT relying on fluorophore switching between longlived states, stands out by its coordinate-targeted sequential sample interrogation using low light levels. While RESOLFT has been shown to discern nanostructures in living cells, the reversibly photoswitchable green fluorescent protein (rsEGFP) employed in these experiments was switched rather slowly and recording lasted tens of minutes. We now report on the generation of rsEGFP2 providing faster switching and the use of this protein to demonstrate 25–250 times faster recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160 · cited 3×
“To remove this background, we deconvolved the final image by Richardson–Lucy (Richardson, 1972; Lucy, 1974) restoration with a 10% diffraction-limited PSF added to the RESOLFT PSF, as detailed previously (Hofmann et al., 2005).”
BackgroundMethodAn iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866 · cited 1×
“To remove this background, we deconvolved the final image by Richardson–Lucy (Richardson, 1972; Lucy, 1974) restoration with a 10% diffraction-limited PSF added to the RESOLFT PSF, as detailed previously (Hofmann et al., 2005).”
MethodDiffraction-unlimited all-optical imaging and writing with a photochromic GFP
Grotjohann, T., Testa, I., Leutenegger, M., Bock, H., Urban, N. T., Lavoie-Cardinal, F., Willig, K. I., Eggeling, C., Jakobs, S., & Hell, S. W. (2011) · Nature · doi:10.1038/nature10497 · Cited by 501 · cited 9×
“Hence the pixel dwell time was 380 μs, which is 25- to 50-fold faster than previously reported using rsEGFP on similar structures (Grotjohann et al., 2011).”
BackgroundMethodInfluentialSelf-citationNanoscopy of living brain slices with low light levels
Testa, I., Urban, N. T., Jakobs, S., Eggeling, C., Willig, K. I., & Hell, S. W. (2012) · Neuron · doi:10.1016/j.neuron.2012.07.028 · Cited by 131
Self-citation
Cited by
Extended-resolution structured illumination imaging of endocytic and cytoskeletal dynamics
Li, D., Shao, L., Chen, B.-C., Zhang, X., Zhang, M., Moses, B., Milkie, D. E., Beach, J. R., Hammer, J. A., Pasham, M., et al. (2015) · Science · doi:10.1126/science.aab3500 · Cited by 748
The Growing and Glowing Toolbox of Fluorescent and Photoactive Proteins
Rodriguez, E. A., Campbell, R. E., Lin, J. Y., Lin, M. Z., Miyawaki, A., Palmer, A. E., Shu, X., Zhang, J., & Tsien, R. Y. (2017) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2016.09.010 · Cited by 633
Light-induced cell damage in live-cell super-resolution microscopy
Wäldchen, S., Lehmann, J., Klein, T., van de Linde, S., & Sauer, M. (2015) · Scientific Reports · doi:10.1038/srep15348 · Cited by 536
Instant super-resolution imaging in live cells and embryos via analog image processing
York, A. G., Chandris, P., Nogare, D. D., Head, J., Wawrzusin, P., Fischer, R. S., Chitnis, A., & Shroff, H. (2013) · Nature Methods · doi:10.1038/nmeth.2687 · Cited by 404
Fluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Metadata
- Authors
- Grotjohann, T., Testa, I., Reuss, M., Brakemann, T., Eggeling, C., Hell, S. W., & Jakobs, S.
- Venue
- eLife
- Publisher
- eLife Sciences Publications, Ltd
- Published
- 2012-12-31
- Volume
- 1
- Pages
- e00248-e00248
- ISSN
- 2050-084X (ISSN-L)
- OpenAlex
- W2098275652
- Cited by
- 229
- References
- 4
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.