Physical limits to magnetogenetics
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
This is an analysis of how magnetic fields affect biological molecules and cells. It was prompted by a series of prominent reports regarding magnetism in biological systems. The first claims to have identified a protein complex that acts like a compass needle to guide magnetic orientation in animals (Qin et al., 2016). Two other articles report magnetic control of membrane conductance by attaching ferritin to an ion channel protein and then tugging the ferritin or heating it with a magnetic field (Stanley et al., 2015; Wheeler et al., 2016). Here I argue that these claims conflict with basic laws of physics. The discrepancies are large: from 5 to 10 log units. If the reported phenomena do in fact occur, they must have causes entirely different from the ones proposed by the authors. The paramagnetic nature of protein complexes is found to seriously limit their utility for engineering magnetically sensitive cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881 · cited 2×
“A magnetic field gradient pulls on ferritin (Figure 1a) Paramagnetic particles experience a force that is proportional to the magnetic field gradient and the induced magnetic moment (Feynman et al., 1963; Ch 35; Pankhurst et al., 2003).”
The Feynman Lectures on Physics
Feynman, R. P., Leighton, R. B., Sands, M., & Treiman, S. B. (1964) · Physics Today · doi:10.1063/1.3051743 · Cited by 2,939
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Maier-Hauff, K., Ulrich, F., Nestler, D., Niehoff, H., Wust, P., Thiesen, B., Orawa, H., Budach, V., & Jordan, A. (2011) · Journal of Neuro-Oncology · doi:10.1007/s11060-010-0389-0 · Cited by 1,429 · cited 1×
“A sample biomedical application is to inject nanoparticles into cancerous tissue, and then damage the tumor selectively by magnetic heating (Hergt et al., 2006; Maier-Hauff et al., 2011).”
BackgroundMagnetosome formation in prokaryotes
Bazylinski, D. A., & Frankel, R. B. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro842 · Cited by 1,210 · cited 3×
“The two are closely linked, because uncovering Nature’s method for magnetosensation can point the way to effectively engineering magnetogenetics.”
BackgroundSize-Sorted Anionic Iron Oxide Nanomagnets as Colloidal Mediators for Magnetic Hyperthermia
Fortin, J.-P., Wilhelm, C., Servais, J., Ménager, C., Bacri, J.-C., & Gazeau, F. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067457e · Cited by 1,038 · cited 2×
“Why is native ferritin such a poor heater? Both theory and experiment show that the efficiency of heating magnetic nanoparticles depends strongly on the particle size, and plummets steeply below 10 nm (Fortin et al., 2007; Purushotham and Ramanujan, 2010).”
BackgroundMagnetic particle hyperthermia: nanoparticle magnetism and materials development for cancer therapy
Hergt, R., Dutz, S., Müller, R., & Zeisberger, M. (2006) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/18/38/s26 · Cited by 977
Piezo1, a mechanically activated ion channel, is required for vascular development in mice
Ranade, S. S., Qiu, Z., Woo, S.-H., Hur, S. S., Murthy, S. E., Cahalan, S. M., Xu, J., Mathur, J., Bandell, M., Coste, B., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1409233111 · Cited by 901 · cited 2×
“eceptors has been measured directly by producing a laminar water flow over the surface of a cell: For TRPV4 channels it amounts to ~20 dyne/cm2 (Soffe et al., 2015); for Piezo1 channels ~50 dyne/cm2 (Ranade et al., 2014). Suppose now that the membrane is decorated with ferritins attached by some linkage, and instead o…”
Background
Cited by
Integration of optogenetics with complementary methodologies in systems neuroscience
Kim, C. K., Adhikari, A., & Deisseroth, K. (2017) · Nature reviews. Neuroscience · doi:10.1038/nrn.2017.15 · Cited by 690
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Long-distance navigation and magnetoreception in migratory animals
Mouritsen, H. (2018) · Nature · doi:10.1038/s41586-018-0176-1 · Cited by 526
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Neuronal control of peripheral insulin sensitivity and glucose metabolism
Ruud, J., Steculorum, S. M., & Brüning, J. C. (2017) · Nature Communications · doi:10.1038/ncomms15259 · Cited by 245
Metadata
- Authors
- Meister, M.
- Venue
- eLife
- Publisher
- eLife Sciences Publications, Ltd
- Published
- 2016-08-16
- Volume
- 5
- ISSN
- 2050-084X (ISSN-L)
- OpenAlex
- W2394488676
- Cited by
- 209
- References
- 47
- FWCI
- 12.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.