Improved Frequency Measurement of the 1S0–3P0 Clock Transition in 87Sr Using a Cs Fountain Clock as a Transfer Oscillator
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Self-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Cited by
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Metadata
- Authors
- Tanabe, T., Akamatsu, D., Kobayashi, T., Takamizawa, A., Yanagimachi, S., Ikegami, T., Suzuyama, T., Inaba, H., Okubo, S., Yasuda, M., Hong, F.-L., Onae, A., & Hosaka, K.
- Venue
- Journal of the Physical Society of Japan
- Publisher
- Physical Society of Japan
- Published
- 2015-11-15
- Volume
- 84
- Issue
- 11
- Pages
- 115002
- ISSN
- 0031-9015 (ISSN-L)
- 1347-4073
- OpenAlex
- W2265805915
- Cited by
- 28
- References
- 4
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Frequency Measurement of the 1S0–3P0 Clock Transition in 87Sr Using a Cs Fountain Clock as a Transfer Oscillator. https://app.cochat.ai/papers/10.7566/jpsj.84.115002
- The paper
- Tanabe, T., Akamatsu, D., Kobayashi, T., Takamizawa, A., Yanagimachi, S., Ikegami, T., Suzuyama, T., Inaba, H., Okubo, S., Yasuda, M., Hong, F.-L., Onae, A., & Hosaka, K. (2015). Improved Frequency Measurement of the 1S0–3P0 Clock Transition in 87Sr Using a Cs Fountain Clock as a Transfer Oscillator. Journal of the Physical Society of Japan. https://doi.org/10.7566/jpsj.84.115002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.