CoChat

Human magnetoencephalogram measurements using newly developed compact module of high-sensitivity atomic magnetometer

Open access
Kamada, Keigo, Sato, Daichi, Ito, Yosuke, Natsukawa, Hiroaki, Okano, Kazuhisa, Mizutani, Natsuhiko, Kobayashi, Tetsuo · 2015 · Japanese Journal of Applied Physics
Cited by 74

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In the field of biomagnetic measurements, optically pumped atomic magnetometers (OPAMs) are expected to be alternative sensors to magnetometers based on superconducting quantum interference devices (SQUIDs). In addition, miniaturized OPAMs are required for practical use. To address this issue, we developed a compact module of a high-sensitivity OPAM with a pump–probe arrangement and potassium used as the sensing atom. Because the noise spectrum density of the OPAM reached 21 fT rms /Hz 1/2 at 10 Hz, we attempted to use it to measure human magnetocardiograms (MEGs). Compared with the results obtained with SQUID-based magnetometers, we could successfully observe distinct features of event-related desynchronization in the 8–13 Hz band associated with eye opening. The results demonstrate the feasibility of using the OPAM module for neuromagnetic field measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7567/jjap.54.026601

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 74

Metadata

Authors
Kamada, K., Sato, D., Ito, Y., Natsukawa, H., Okano, K., Mizutani, N., & Kobayashi, T.
Venue
Japanese Journal of Applied Physics
Published
2015-01-13
Volume
54
Issue
2
Pages
026601
ISSN
  • 0021-4922 (ISSN-L)
  • 1347-4065
OpenAlex
W2000198282
Cited by
74
References
4
FWCI
3.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human magnetoencephalogram measurements using newly developed compact module of high-sensitivity atomic magnetometer. https://app.cochat.ai/papers/10.7567/jjap.54.026601
The paper
Kamada, K., Sato, D., Ito, Y., Natsukawa, H., Okano, K., Mizutani, N., & Kobayashi, T. (2015). Human magnetoencephalogram measurements using newly developed compact module of high-sensitivity atomic magnetometer. Japanese Journal of Applied Physics. https://doi.org/10.7567/jjap.54.026601

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.