CoChat

Performance of Doppler ultrasonography as a screening test in low risk pregnancies: results of a multicentric study.

Todros, T, Ferrazzi, E, Arduini, D, Bastonero, S, Bezzeccheri, V, Biolcati, M, Bonazzi, B, Gabrielli, S, Pilu, G L, Rizzo, G · 1995 · Journal of Ultrasound in Medicine
Cited by 48

The DOI matches its Crossref record.

Abstract

To assess the efficacy of the Doppler velocimetry of the uterine and umbilical arteries as a screening test for preeclampsia and fetal growth retardation, we studied 916 low risk pregnancies. The S/D ratios of the uterine and umbilical arteries were obtained at 19 to 24 weeks and at 26 to 31 weeks of gestational age. Mean values, receiver operator curves, and the diagnostic accuracy of the tests were calculated for the following end-points: (1) pregnancy-induced hypertension, (2) low birth weight for gestational age, (3) small for gestational age with abnormal outcome, (4) pregnancy-induced hypertension needing preterm delivery. The prevalences for these outcomes were 3.4%, 4.6%, 1%, and 0.7%, respectively. The study was blinded. The umbilical and uterine artery S/D ratios were significantly higher in the abnormal than in the normal outcome group. When uterine arteries were studied at 19 to 24 weeks, sensitivity was 59% in the detection of pregnancy-induced hypertension, 11% in the detection of small for gestational age fetuses, 33% in the detection of small for gestational age fetuses with abnormal outcome, and 83% in the detection of pregnancy induced hypertension needing preterm delivery; the corresponding values for specificity were 69%, 94%, 94%, and 68%. At 26 to 31 weeks the sensitivity values were respectively, 69%, 58%, 75%, and 100% and specificity values were 80%, 59%, 39%, and 79%. When umbilical arteries were studied at 19 to 24 weeks, sensitivity was 38% in the detection of pregnancy-induced hypertension, 46% in the detection of small for gestational age fetuses, 78% in the detection of small for gestational age fetuses with abnormal outcome, and 67% in the detection of pregnancy-induced hypertension needing preterm delivery. The corresponding values of specificity were 74% for all four groups. At 26 to 31 weeks the sensitivity values were 38%, 43%, 87%, and 67%, respectively, and specificity values were 80% for all four groups. We concluded that Doppler examinations of the uterine and umbilical arteries can detect, at midpregnancy, the severe forms of pregnancy-induced hypertension and small for gestational age fetuses but they cannot be used to screen a low risk population in which the prevalence of the disease is low, and hence the positive predictive value is low.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7863/jum.1995.14.5.343

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Todros, T., Ferrazzi, E., Arduini, D., Bastonero, S., Bezzeccheri, V, Biolcati, M., Bonazzi, B., Gabrielli, S., Pilu, G. L., & Rizzo, G.
Venue
Journal of Ultrasound in Medicine
Publisher
Wiley
Published
1995-05
Volume
14
Issue
5
Pages
343-348
ISSN
0278-4297 (ISSN-L)
OpenAlex
W1955529975
Cited by
48
References
0
FWCI
5.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.