Birth weight prediction by three‐dimensional ultrasonography: fractional limb volume.
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
To introduce fractional limb volume as a new ultrasonographic parameter, validate reliability of fractional limb volume measurements, develop new birth weight prediction models, and examine their practical utility for estimating fetal weight during late pregnancy. Healthy late‐third‐trimester fetuses were prospectively scanned by two‐ and three‐dimensional ultrasonography within 4 days of delivery. Volume data sets were subsequently used to extract several standard ultrasonographic measurements. Fractional limb volumes of the upper arm and thigh were based on 50% of diaphyseal bone length. Intraclass correlation was used to analyze interobserver and intraobserver reliability of fractional limb volume measurements. Several weight prediction models were developed by linear regression analysis. New prediction models were prospectively compared with the Hadlock formula in 30 healthy late‐third‐trimester fetuses. One hundred fetuses were scanned at a mean +/‐ SD menstrual age of 39.2 +/‐ 1.2 weeks. Intraclass correlation indicated a significant degree of interobserver and intraobserver reliability for fractional thigh volume. Fractional thigh volume (r = 0.86), fractional upper arm volume (r = 0.83), abdominal circumference (r = 0.83), and midthigh circumference (r = 0.82) were most highly correlated with birth weight. The best prediction model (abdominal circumference and fractional thigh volume) gave weight estimates that deviated from actual birth weight by ‐0.025% +/‐ 7.8%. For late‐third‐trimester fetuses, the Hadlock model yielded errors of 9.0% +/‐ 9.0%. Prospective testing confirmed superior performance of the new prediction model, which gave accuracy of 2.3% +/‐ 6.6% (Hadlock method, 8.4% +/‐ 8.7%). It correctly predicted 20 of 30 birth weights to within 5% of actual weight. By comparison, the Hadlock model predicted only 6 of 30 birth weights to within 5% of actual weight. A new birth weight prediction model, based on fractional thigh volume and abdominal circumference, is reliable during the late third trimester. It provides a means for including soft tissue evaluation for birth weight prediction. This rapid technique avoids technical limitations that currently hinder the practical implementation of three‐dimensional ultrasonography for estimating birth weight.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682 · cited 1×
“4): (1) estimated fetal weight (EFW) was determined by using functions that included various sonographic parameters; (2) prediction errors were determined as the difference between EFW and actual BW; (3) prediction errors (EFW – BW) were plotted against actual BWs, and the relationship between EFW – BW and BW was dete…”
MethodSelf-citationThe estimation of fetal weight by computer-assisted analysis
Warsof, S. L., Gohari, P., Berkowitz, R. L., & Hobbins, J. C. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90058-8 · Cited by 355
Evaluation of a clinical test. I: Assessment of reliability
Kha, K. S., & Chien, P. F. W. (2001) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2001.00150.x · Cited by 135
Cited by
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
Defining normal and abnormal fetal growth: promises and challenges
Zhang, J., Merialdi, M., Platt, L. D., & Kramer, M. S. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.10.889 · Cited by 264
Sonographic Fetal Weight Estimation: Which Model Should Be Used?
Melamed, N., Yogev, Y., Meizner, I., Mashiach, R., Bardin, R., & Ben-Haroush, A. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.5.617 · Cited by 112
Metadata
- Authors
- Lee, W., Deter, R. L., Ebersole, J. D., Huang, R., Blanckaert, K., & Romero, R.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2001-12
- Volume
- 20
- Issue
- 12
- Pages
- 1283-1292
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W1849644463
- Cited by
- 145
- References
- 3
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.