Prenatal Diagnosis of Placenta Accreta: Sonography or Magnetic Resonance Imaging?
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to compare the accuracy of transabdominal sonography and magnetic resonance imaging (MRI) for prenatal diagnosis of placenta accreta. METHODS: A historical cohort study was undertaken at 3 institutions identifying women at risk for placenta accreta who had undergone both sonography and MRI prenatally. Sonographic and MRI findings were compared with the final diagnosis as determined at delivery and by pathologic examination. RESULTS: Thirty-two patients who had both sonography and MRI prenatally to evaluate for placenta accreta were identified. Of these, 15 had confirmation of placenta accreta at delivery. Sonography correctly identified the presence of placenta accreta in 14 of 15 patients (93% sensitivity; 95% confidence interval [CI], 80%-100%) and the absence of placenta accreta in 12 of 17 patients (71% specificity; 95% CI, 49%-93%). Magnetic resonance imaging correctly identified the presence of placenta accreta in 12 of 15 patients (80% sensitivity; 95% CI, 60%-100%) and the absence of placenta accreta in 11 of 17 patients (65% specificity; 95% CI, 42%-88%). In 7 of 32 cases, sonography and MRI had discordant diagnoses: sonography was correct in 5 cases, and MRI was correct in 2. There was no statistical difference in sensitivity (P = .25) or specificity (P = .5) between sonography and MRI. CONCLUSIONS: Both sonography and MRI have fairly good sensitivity for prenatal diagnosis of placenta accreta; however, specificity does not appear to be as good as reported in other studies. In the case of inconclusive findings with one imaging modality, the other modality may be useful for clarifying the diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical risk factors for placenta previa–placenta accreta
Miller, D. A., Chollet, J. A., & Goodwin, T. M. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70463-0 · Cited by 1,106 · cited 1×
“Examples of studies designated inconclusive included the following: (1) a study in which a single nonspecific feature of placenta accreta was seen on imaging, but the overall study was thought to have low probability; and (2) a study that was limited by poor quality.”
ResultACR Guidance Document for Safe MR Practices: 2007
Kanal, E., Barkovich, A. J., Bell, C., Borgstede, J. P., Bradley, W. G., Froelich, J. W., Gilk, T., Gimbel, J. R., Gosbee, J., Kuhni-Kaminski, E., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1616 · Cited by 787
Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta
Warshak, C. R., Eskander, R., Hull, A. D., Scioscia, A. L., Mattrey, R. F., Benirschke, K., & Resnik, R. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000233155.62906.6d · Cited by 515
Sonographic detection of placenta accreta in the second and third trimesters of pregnancy
Comstock, C. H., Love, J. J., Bronsteen, R. A., Lee, W., Vettraino, I. M., Huang, R. R., & Lorenz, R. P. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2003.11.024 · Cited by 470
Finberg, H. J., & Williams, J. W. (1992) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1992.11.7.333 · Cited by 456
Placenta Accreta—Summary of 10 Years: A Survey of 310 Cases
Gielchinsky, Y., Rojansky, N., Fasouliotis, S. J., & Ezra, Y. (2002) · Placenta · doi:10.1053/plac.2001.0764 · Cited by 376
Placenta accreta: evaluation with color Doppler US, power Doppler US, and MR imaging.
Levine, D., Hulka, C. A., Ludmir, J., Li, W., & Edelman, R. R. (1997) · Radiology · doi:10.1148/radiology.205.3.9393534 · Cited by 355
Antenatal diagnosis of placenta accreta: a review
Comstock, C. H. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1926 · Cited by 327
Prenatal diagnosis of placenta previa accreta by transabdominal color Doppler ultrasound
Chou, M. M., Ho, E. S. C., & Lee, Y. H. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00018.x · Cited by 284
The value of specific MRI features in the evaluation of suspected placental invasion
Lax, A., Prince, M. R., Mennitt, K. W., Schwebach, J. R., & Budorick, N. E. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.10.007 · Cited by 276
Cited by
D'Antonio, F., Iacovella, C., & Bhide, A. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13194 · Cited by 398
Management of Asherman’s syndrome
March, C. M. (2011) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2010.11.018 · Cited by 341
D'Antonio, F., Iacovella, C., Palacios-Jaraquemada, J., Bruno, C. H., Manzoli, L., & Bhide, A. (2014) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13327 · Cited by 324
Imaging of the Placenta: A Multimodality Pictorial Review
Elsayes, K. M., Trout, A. T., Friedkin, A. M., Liu, P. S., Bude, R. O., Platt, J. F., & Menias, C. O. (2009) · RadioGraphics · doi:10.1148/rg.295085242 · Cited by 222
Jauniaux, E., Collins, S. L., Jurkovic, D., & Burton, G. J. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.07.044 · Cited by 208
Metadata
- Authors
- Dwyer, B. K., Belogolovkin, V., Tran, L., Rao, A., Carroll, I., Barth, R., & Chitkara, U.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2008-09
- Volume
- 27
- Issue
- 9
- Pages
- 1275-1281
- ISSN
- 0278-4297 (ISSN-L)
- OpenAlex
- W2164691078
- Cited by
- 213
- References
- 19
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prenatal Diagnosis of Placenta Accreta: Sonography or Magnetic Resonance Imaging? https://app.cochat.ai/papers/10.7863/jum.2008.27.9.1275
- The paper
- Dwyer, B. K., Belogolovkin, V., Tran, L., Rao, A., Carroll, I., Barth, R., & Chitkara, U. (2008). Prenatal Diagnosis of Placenta Accreta: Sonography or Magnetic Resonance Imaging? Journal of Ultrasound in Medicine. https://doi.org/10.7863/jum.2008.27.9.1275
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.