Prenatal Diagnosis of Placenta Accreta: Sonography or Magnetic Resonance Imaging?
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to compare the accuracy of transabdominal sonography and magnetic resonance imaging (MRI) for prenatal diagnosis of placenta accreta. METHODS: A historical cohort study was undertaken at 3 institutions identifying women at risk for placenta accreta who had undergone both sonography and MRI prenatally. Sonographic and MRI findings were compared with the final diagnosis as determined at delivery and by pathologic examination. RESULTS: Thirty-two patients who had both sonography and MRI prenatally to evaluate for placenta accreta were identified. Of these, 15 had confirmation of placenta accreta at delivery. Sonography correctly identified the presence of placenta accreta in 14 of 15 patients (93% sensitivity; 95% confidence interval [CI], 80%-100%) and the absence of placenta accreta in 12 of 17 patients (71% specificity; 95% CI, 49%-93%). Magnetic resonance imaging correctly identified the presence of placenta accreta in 12 of 15 patients (80% sensitivity; 95% CI, 60%-100%) and the absence of placenta accreta in 11 of 17 patients (65% specificity; 95% CI, 42%-88%). In 7 of 32 cases, sonography and MRI had discordant diagnoses: sonography was correct in 5 cases, and MRI was correct in 2. There was no statistical difference in sensitivity (P = .25) or specificity (P = .5) between sonography and MRI. CONCLUSIONS: Both sonography and MRI have fairly good sensitivity for prenatal diagnosis of placenta accreta; however, specificity does not appear to be as good as reported in other studies. In the case of inconclusive findings with one imaging modality, the other modality may be useful for clarifying the diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical risk factors for placenta previa–placenta accreta
Miller, D. A., Chollet, J. A., & Goodwin, T. M. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70463-0 · Cited by 1,106 · cited 1×
“Examples of studies designated inconclusive included the following: (1) a study in which a single nonspecific feature of placenta accreta was seen on imaging, but the overall study was thought to have low probability; and (2) a study that was limited by poor quality.”
ResultACR Guidance Document for Safe MR Practices: 2007
Kanal, E., Barkovich, A. J., Bell, C., Borgstede, J. P., Bradley, W. G., Froelich, J. W., Gilk, T., Gimbel, J. R., Gosbee, J., Kuhni-Kaminski, E., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1616 · Cited by 787
Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta
Warshak, C. R., Eskander, R., Hull, A. D., Scioscia, A. L., Mattrey, R. F., Benirschke, K., & Resnik, R. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000233155.62906.6d · Cited by 515
Sonographic detection of placenta accreta in the second and third trimesters of pregnancy
Comstock, C. H., Love, J. J., Bronsteen, R. A., Lee, W., Vettraino, I. M., Huang, R. R., & Lorenz, R. P. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2003.11.024 · Cited by 470
Finberg, H. J., & Williams, J. W. (1992) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1992.11.7.333 · Cited by 456
Placenta Accreta—Summary of 10 Years: A Survey of 310 Cases
Gielchinsky, Y., Rojansky, N., Fasouliotis, S. J., & Ezra, Y. (2002) · Placenta · doi:10.1053/plac.2001.0764 · Cited by 376
Placenta accreta: evaluation with color Doppler US, power Doppler US, and MR imaging.
Levine, D., Hulka, C. A., Ludmir, J., Li, W., & Edelman, R. R. (1997) · Radiology · doi:10.1148/radiology.205.3.9393534 · Cited by 355
Antenatal diagnosis of placenta accreta: a review
Comstock, C. H. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1926 · Cited by 327
Prenatal diagnosis of placenta previa accreta by transabdominal color Doppler ultrasound
Chou, M. M., Ho, E. S. C., & Lee, Y. H. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00018.x · Cited by 284
The value of specific MRI features in the evaluation of suspected placental invasion
Lax, A., Prince, M. R., Mennitt, K. W., Schwebach, J. R., & Budorick, N. E. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.10.007 · Cited by 276
Cited by
D'Antonio, F., Iacovella, C., & Bhide, A. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13194 · Cited by 398
Management of Asherman’s syndrome
March, C. M. (2011) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2010.11.018 · Cited by 341
D'Antonio, F., Iacovella, C., Palacios-Jaraquemada, J., Bruno, C. H., Manzoli, L., & Bhide, A. (2014) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13327 · Cited by 324
Imaging of the Placenta: A Multimodality Pictorial Review
Elsayes, K. M., Trout, A. T., Friedkin, A. M., Liu, P. S., Bude, R. O., Platt, J. F., & Menias, C. O. (2009) · RadioGraphics · doi:10.1148/rg.295085242 · Cited by 222
Jauniaux, E., Collins, S. L., Jurkovic, D., & Burton, G. J. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.07.044 · Cited by 208
Placenta accreta is associated with IVF pregnancies: a retrospective chart review
Esh-Broder, E., Ariel, I., Abas-Bashir, N., Bdolah, Y., & Celnikier, D. H. (2011) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2011.02976.x · Cited by 190
The antenatal diagnosis of placenta accreta
Comstock, C., & Bronsteen, R. (2014) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12557 · Cited by 164
Prenatal Diagnosis of Placenta Accreta: Is Sonography All We Need?
Berkley, E. M., & Abuhamad, A. Z. (2013) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.32.8.1345 · Cited by 162
Accuracy of ultrasound for the prediction of placenta accreta
Bowman, Z. S., Eller, A. G., Kennedy, A. M., Richards, D. S., Winter, T. C., Woodward, P. J., & Silver, R. M. (2014) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.03.029 · Cited by 151
Dilauro, M. D., Dason, S., & Athreya, S. (2012) · Clinical Radiology · doi:10.1016/j.crad.2011.10.031 · Cited by 121
Einerson, B. D., Rodriguez, C. E., Kennedy, A. M., Woodward, P. J., Donnelly, M. A., & Silver, R. M. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.03.013 · Cited by 121
Meng, X., Xie, L., & Song, W. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.05.017 · Cited by 118
Tinari, S., Buca, D., Cali, G., Timor‐Tritsch, I., Palacios‐Jaraquemada, J., Rizzo, G., Lucidi, A., Di Mascio, D., Liberati, M., & D'Antonio, F. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22183 · Cited by 89
The MRI features of placental adhesion disorder and their diagnostic significance: systematic review
Rahaim, N. S. A., & Whitby, E. H. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.04.010 · Cited by 66
“…et al., 2013 Maher et al., 2013 Alamo et al., 2012 Shweel et al., 2012 Mansour, Elkhyat, 2011 Lim et al., 2011 Derman et al., 2011 Teo et al., 2009 Masselli et al., 2008 Dwyer et al., 2008 1) Abnormal uterine bulging No details No details No details Sensitivity 59.1 Specificity 41.3 5/28 (17.8”
BackgroundInfluentialDo, Q. N., Lewis, M. A., Xi, Y., Madhuranthakam, A. J., Happe, S. K., Dashe, J. S., Lenkinski, R. E., Khan, A., & Twickler, D. M. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26883 · Cited by 61
Horgan, R., & Abuhamad, A. (2022) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2022.02.004 · Cited by 59
Management of placenta accreta: a survey of Maternal-Fetal Medicine practitioners
Jolley, J. A., Nageotte, M. P., Wing, D. A., & Shrivastava, V. K. (2012) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2011.594467 · Cited by 55
“Ultrasound remains the primary diagnostic modality for abnormal placentation, but some investigators have looked to alternate imaging modalities to increase the sensitivity of detection [11,13,14,15,16].”
BackgroundMillischer, A., Salomon, L., Porcher, R., Brasseur‐Daudruy, M., Gourdier, A., Hornoy, P., Silvera, S., Loisel, D., Tsatsaris, V, Delorme, B., et al. (2017) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.14164 · Cited by 43
Gagnon, J., Boucher, L., Kaufman, I., Brown, R., & Moore, A. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0038-0 · Cited by 33
“The use of ultrasound has sensitivity of 80-100% and specificity of 49-93%, while magnetic resonance imaging has a sensitivity of 60-100% and specificity of 42-88%.(14) The use of magnetic resonance imaging in conjunction with ultrasound may improve the accuracy, especially when the placenta invades through the myomet…”
Background
Metadata
- Authors
- Dwyer, B. K., Belogolovkin, V., Tran, L., Rao, A., Carroll, I., Barth, R., & Chitkara, U.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2008-09
- Volume
- 27
- Issue
- 9
- Pages
- 1275-1281
- ISSN
- 0278-4297 (ISSN-L)
- OpenAlex
- W2164691078
- Cited by
- 213
- References
- 19
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.