CoChat

Doppler Sonographic Criteria for the Diagnosis of Inferior Mesenteric Artery Stenosis

Pellerito, John S., Revzin, Margarita V., Tsang, James C., Greben, Craig R., Naidich, James B. · 2009 · Journal of Ultrasound in Medicine
Cited by 45

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The purpose of this study was to define the optimal Doppler criteria for the diagnosis of inferior mesenteric artery (IMA) stenosis in patients with suspected chronic mesenteric ischemia (CMI). METHODS: A retrospective review of 205 dedicated color and pulsed Doppler sonographic studies of mesenteric arteries was performed in 205 patients. All studies were performed in patients with suspected CMI. Correlative angiography was available in 50 patients. RESULTS: The IMA was visualized in 176 of 205 Doppler sonographic examinations (86%) and in 92% of the correlative studies. The visualization rate for the detection of a patent IMA by Doppler sonography in this series was 90%. The ranges of the peak systolic velocity (PSV), end-diastolic velocity (EDV), and mesenteric-aortic velocity ratio (MAR) in the nonstenotic IMA were 70 to 200 cm/s, 0 to 33 cm/s, and 0.7 to 3.7, respectively. The ranges of the PSV, EDV, and MAR in IMA stenosis were 200 to 485 cm/s, 0 to 177 cm/s, and 0.69 to 8.1. The threshold values for severe IMA stenosis by logistic regression analysis (n = 42) were as follows: PSV, greater than 200 cm/s; EDV, greater than 25 cm/s; and MAR, greater than 2.5, with sensitivities of 90%, 40%, and 80%; specificities of 97%, 91%, and 88%; positive predictive values (PPVs) of 90%, 57%, and 67%; negative predictive values (NPVs) of 97%, 83%, and 93%; and accuracy of 95%, 79%, and 86%, respectively. CONCLUSIONS: We found that a PSV of greater than 200 cm/s was the best criterion for the diagnosis of IMA stenosis. The sensitivity, specificity, PPV, NPV, and accuracy for the PSV were 90%, 97%, 90%, 97%, and 95%, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7863/jum.2009.28.5.641

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 45

Metadata

Authors
Pellerito, J. S., Revzin, M. V., Tsang, J. C., Greben, C. R., & Naidich, J. B.
Venue
Journal of Ultrasound in Medicine
Publisher
Wiley
Published
2009-05
Volume
28
Issue
5
Pages
641-650
ISSN
0278-4297 (ISSN-L)
OpenAlex
W2104137860
Cited by
45
References
4
FWCI
3.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Doppler Sonographic Criteria for the Diagnosis of Inferior Mesenteric Artery Stenosis. https://app.cochat.ai/papers/10.7863/jum.2009.28.5.641
The paper
Pellerito, J. S., Revzin, M. V., Tsang, J. C., Greben, C. R., & Naidich, J. B. (2009). Doppler Sonographic Criteria for the Diagnosis of Inferior Mesenteric Artery Stenosis. Journal of Ultrasound in Medicine. https://doi.org/10.7863/jum.2009.28.5.641

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.