CoChat

Blood‐Brain Barrier Closure Time After Controlled Ultrasound‐Induced Opening Is Independent of Opening Volume

Open access
O'Reilly, Meaghan A., Hough, Olivia, Hynynen, Kullervo · 2017 · Journal of Ultrasound in Medicine
Cited by 95

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objectives: Microbubble‐mediated focused ultrasound (US) opening of the blood‐brain barrier (BBB) has shown promising results for the treatment of brain tumors and conditions such as Alzheimer disease. Practical clinical implementation of focused US treatments would aim to treat a substantial portion of the brain; thus, the safety of opening large volumes must be investigated. This study investigated whether the opened volume affects the time for the BBB to be restored after treatment. Methods: Sprague Dawley rats (n = 5) received bilateral focused US treatments. One hemisphere received a single sonication, and the contralateral hemisphere was targeted with 4 overlapping foci. Contrast‐enhanced T1‐weighted magnetic resonance imaging was used to assess the integrity of the BBB at 0, 6, and 24 hours after focused US. Results: At time 0, there was no significant difference in the mean enhancement between the single‐ and multi‐point sonications (mean ± SD, 29.7% ± 18.4% versus 29.7% ± 24.1%; P = .9975). The mean cross‐sectional area of the BBB opening resulting from the multi‐point sonication was approximately 3.5‐fold larger than that of the single‐point case (14.2 ± 4.7 versus 4.1 ± 3.3 mm 2; P < .0001). The opened volumes in 9 of 10 hemispheres were closed by 6 hours after focused US. The remaining treatment location had substantially reduced enhancement at 6 hours and was closed by 24 hours. Histologic analysis revealed small morphologic changes associated with this location. T2‐weighted images at 6 and 24 hours showed no signs of edema. T2*‐weighted images obtained at 6 hours also showed no signs hemorrhage in any animal. Conclusions: The time for the BBB to close after focused US was independent of the opening volume on the time scale investigated. No differences in treatment effects were observable by magnetic resonance imaging follow‐up between larger‐ and smaller‐volume sonications, suggesting that larger‐volume BBB opening can be performed safely.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7863/ultra.16.02005

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 95

Metadata

Authors
O'Reilly, M. A., Hough, O., & Hynynen, K.
Venue
Journal of Ultrasound in Medicine
Publisher
Wiley
Published
2017-01-21
Volume
36
Issue
3
Pages
475-483
ISSN
  • 0278-4297 (ISSN-L)
  • 1550-9613
OpenAlex
W2571555848
Cited by
95
References
4
FWCI
5.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood‐Brain Barrier Closure Time After Controlled Ultrasound‐Induced Opening Is Independent of Opening Volume. https://app.cochat.ai/papers/10.7863/ultra.16.02005
The paper
O'Reilly, M. A., Hough, O., & Hynynen, K. (2017). Blood‐Brain Barrier Closure Time After Controlled Ultrasound‐Induced Opening Is Independent of Opening Volume. Journal of Ultrasound in Medicine. https://doi.org/10.7863/ultra.16.02005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.