CoChat

Assessment of the Accuracy of Multiple Sonographic Fetal Weight Estimation Formulas: A 10-Year Experience From a Single Center

Barel, O., Vaknin, Z., Tovbin, J., Herman, A., Maymon, R. · 2013 · Journal of Ultrasound in Medicine
Cited by 43

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: The primary aim of this study was to compare the accuracy of sonographic fetal weight estimation models. The secondary aim was to define the most accurate time (4-7 or 3 days before delivery) for evaluating fetal weight. METHODS: In this retrospective cohort study, a total of 12,798 sonographic fetal weight estimations were analyzed, of which 9459 were performed within 3 days of delivery and 3339 within 4 to 7 days. The cohort included all singleton pregnancies recorded at a single medical center from January 2000 to December 2010, with 24 weeks' gestation minimum. Predicted birth weights were calculated according to 23 sonographic fetal weight estimation models; in total, 294,354 sonographic weight estimations were evaluated and compared to the actual birth weights. RESULTS: The accuracy of the models in predicting birth weight differed considerably. The most accurate models used 3 or more fetal measurements followed by models using abdominal circumference only. The models developed by Sabbagha et al (Am J Obstet Gynecol 1989; 160:854-862) proved most accurate, with a mean percent error of -0.2% and greater than 92% of estimates within 15% of birth weight (P < .05). Nineteen sonographic fetal weight estimation models (82.6%) better predicted fetal weight at 4 to 7 days before delivery (P < .001). Twenty-two (95%) of the models were less accurate at the extreme ends of fetal weight. CONCLUSIONS: Different formulas for fetal weight estimation vary greatly; we recommend that each center should evaluate the most accurate formula according to its attending population. Estimation of fetal weight performed 4 to 7 days before delivery using most models was more accurate than estimations performed 3 days before delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7863/ultra.32.5.815

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 43

Metadata

Authors
Barel, O., Vaknin, Z., Tovbin, J., Herman, A., & Maymon, R.
Venue
Journal of Ultrasound in Medicine
Publisher
Wiley
Published
2013-04-25
Volume
32
Issue
5
Pages
815-823
ISSN
  • 0278-4297 (ISSN-L)
  • 1550-9613
OpenAlex
W2060011431
Cited by
43
References
4
FWCI
2.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of the Accuracy of Multiple Sonographic Fetal Weight Estimation Formulas: A 10-Year Experience From a Single Center. https://app.cochat.ai/papers/10.7863/ultra.32.5.815
The paper
Barel, O., Vaknin, Z., Tovbin, J., Herman, A., & Maymon, R. (2013). Assessment of the Accuracy of Multiple Sonographic Fetal Weight Estimation Formulas: A 10-Year Experience From a Single Center. Journal of Ultrasound in Medicine. https://doi.org/10.7863/ultra.32.5.815

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.