Sonography of the Optic Nerve Sheath Diameter for Detection of Raised Intracranial Pressure Compared to Computed Tomography: A Systematic Review and Meta‐analysis
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Objectives: The diagnosis of raised intracranial pressure (ICP) is important in many critically ill patients. The optic nerve sheath is contiguous with the subarachnoid space; thus, an increase in ICP results in a corresponding increase in the optic nerve sheath diameter. The objective of this study was to assess the diagnostic accuracy of sonography of the optic nerve sheath diameter compared to computed tomography (CT) for predicting raised ICP. Methods: We searched PubMed, EMBASE, and the Cochrane database from 1986 to August 2013 and performed hand searches. Two independent reviewers extracted data. Study quality was assessed by using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. We calculated κ agreement for study selection and evaluated clinical and quality homogeneity before the meta‐analysis. Results: From 1214 studies, we selected 45 for full review. Twelve studies with 478 participants were included (κ = 0.89). Ocular sonography yielded sensitivity of 95.6% (95% confidence interval [CI], 87.7%–98.5%), specificity of 92.3% (95% CI, 77.9%–98.4%), a positive likelihood ratio of 12.5 (95% CI, 4.16–37.5), and a negative likelihood ratio of 0.05 (95% CI, 0.02–0.14). Average quality according to the QUADAS tool was 7.4 of 11. There was moderate to high heterogeneity based on the prediction ellipse area and variance logit of sensitivity (2.1754) and specificity (2.6720). Conclusions: Ocular sonography shows good diagnostic test accuracy for detecting raised ICP compared to CT: specifically, high sensitivity for ruling out raised ICP in a low‐risk group and high specificity for ruling in raised ICP in a high‐risk group. This noninvasive point‐of‐care method could lead to rapid interventions for raised ICP, assist centers without CT, and monitor patients during transport or as part of a protocol to reduce CT use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure
Kimberly, H. H., Shah, S., Marill, K., & Noble, V. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2007.00031.x · Cited by 541
Geeraerts, T., Launey, Y., Martin, L., Pottecher, J., Vigué, B., Duranteau, J., & Benhamou, D. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0797-6 · Cited by 510
Geeraerts, T., Merceron, S., Benhamou, D., Vigué, B., & Duranteau, J. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1149-x · Cited by 425
Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Raboel, P. H., Bartek, J., Andresen, M., Bellander, B. M., & Romner, B. (2012) · Critical Care Research and Practice · doi:10.1155/2012/950393 · Cited by 416
Moretti, R., Pizzi, B., Cassini, F., & Vivaldi, N. (2009) · Neurocritical Care · doi:10.1007/s12028-009-9250-8 · Cited by 246
Ocular Ultrasound to Detect Intracranial Hypertension in Trauma Patients
Cammarata, G., Ristagno, G., Cammarata, A., Mannanici, G., Denaro, C., & Gullo, A. (2011) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3182220673 · Cited by 100
MetaDAS: A SAS macro for meta-analysis of diagnostic accuracy studies
Takwoingi, Y., & Deeks, J. J. (2010) · Cited by 80
Transorbital Sonographic Monitoring of Optic Nerve Diameter in Patients With Severe Brain Injury
Karakitsos, D., Soldatos, T. G., Gouliamos, A., Armaganidis, A., Poularas, J., Kalogeromitros, A., Boletis, J. N., Kostakis, A. G., & Karabinis, A. (2006) · Transplantation Proceedings · doi:10.1016/j.transproceed.2006.10.185 · Cited by 75
Wilczynski, N. L., Haynes, R. B., & the Hedges Team (2005) · BMC Medicine · doi:10.1186/1741-7015-3-7 · Cited by 71
Metadata
- Authors
- Ohle, R., McIsaac, S. M., Woo, M. Y., & Perry, J. J.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2015-07
- Volume
- 34
- Issue
- 7
- Pages
- 1285-1294
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W2227766311
- Cited by
- 204
- References
- 11
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.