Defining the Incidence of Cardiorespiratory Instability in Patients in Step-down Units Using an Electronic Integrated Monitoring System
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To our knowledge, detection of cardiorespiratory instability using noninvasive monitoring via electronic integrated monitoring systems (IMSs) in intermediate or step-down units (SDUs) has not been described. We undertook this study to characterize respiratory status in an SDU population, to define features of cardiorespiratory instability, and to evaluate an IMS index value that should trigger medical emergency team (MET) activation. METHODS: This descriptive, prospective, single-blinded, observational study evaluated all patients in a 24-bed SDU in a university medical center during 8 weeks from November 16, 2006, to January 11, 2007. An IMS (BioSign; OBS Medical, Carmel, Indiana) was inserted into the standard noninvasive hardwired monitoring system and used heart rate, blood pressure, respiratory rate, and peripheral oxygen saturation by pulse oximetry to develop a single neural networked signal, or BioSign Index (BSI). Data were analyzed for cardiorespiratory instability according to BSI trigger value and local MET activation criteria. Staff were blinded to BSI data collected in 326 patients (total census). RESULTS: Data for 18 248 hours of continuous monitoring were captured. Data for peripheral oxygen saturation by pulse oximetry were absent in 30% of monitored hours despite being a standard of care. Cardiorespiratory status in most patients (243 of 326 [74.5%]) was stable throughout their SDU stay, and instability in the remaining patients (83 of 326 [25%]) was exhibited infrequently. We recorded 111 MET activation criteria events caused by cardiorespiratory instability in 59 patients, but MET activation for this cause occurred in only 7 patients. All MET events were detected by BSI in advance (mean, 6.3 hours) in a bimodal distribution (>6 hours and < or =45 minutes). CONCLUSIONS: Cardiorespiratory instability, while uncommon and often unrecognized, was preceded by elevation of the IMS index. Continuous noninvasive monitoring augmented by IMS provides sensitive detection of early instability in patients in SDUs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adapting a clinical comorbidity index for use with ICD-9-CM administrative databases
DEYO, R. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90133-8 · Cited by 10,452
Hospital Nurse Staffing and Patient Mortality, Nurse Burnout, and Job Dissatisfaction
Aiken, L. H. (2002) · JAMA · doi:10.1001/jama.288.16.1987 · Cited by 5,226
Impact of a critical care outreach team on critical care readmissions and mortality
Garcea, G., Thomasset, S., Mcclelland, L., Leslie, A., & Berry, D. P. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2004.00509.x · Cited by 75
Cited by
Pimentel, M. A. F., Clifton, D. A., Clifton, L., & Tarassenko, L. (2014) · Signal Processing · doi:10.1016/j.sigpro.2013.12.026 · Cited by 1,649
“This system was used for monitoring patients in a clinical trial involving 336 patients [145], and it was able to provide early warning of adverse physiological events.”
MethodDeVita, M. A., Smith, G. B., Adam, S. K., Adams-Pizarro, I., Buist, M., Bellomo, R., Bonello, R., Cerchiari, E., Farlow, B., Goldsmith, D., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2009.12.008 · Cited by 366
Self-citationChipara, O., Lu, C., Bailey, T. C., & Roman, G.-C. (2010) · Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/1869983.1869999 · Cited by 232
“Automatic scoring systems aimed at identifying clinical deterioration in patients based on their vital signs are being developed [13, 14].”
BackgroundBellomo, R., Ackerman, M., Bailey, M., Beale, R., Clancy, G., Danesh, V., Hvarfner, A., Jimenez, E., Konrad, D., Lecardo, M., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318255d9a0 · Cited by 228
“Other investigators have assessed the role of continuous electronic integrated monitoring systems in the high dependency/step-down environment and reported earlier detection of cardiorespiratory deterioration (23) and decreased the prevalence and duration of episodes of cardiorespiratory instability (24).”
BackgroundThe value of vital sign trends for detecting clinical deterioration on the wards
Churpek, M. M., Adhikari, R., & Edelson, D. P. (2016) · Resuscitation · doi:10.1016/j.resuscitation.2016.02.005 · Cited by 226
Metadata
- Authors
- Hravnak, M.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2008-06-23
- Volume
- 168
- Issue
- 12
- Pages
- 1300
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2070274899
- Cited by
- 132
- References
- 3
- FWCI
- 13.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.