Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,273

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Breast Imaging Reporting and Data System: Inter- and Intraobserver Variability in Feature Analysis and Final Assessment

Berg, Wendie A., Campassi, Cristina, Langenberg, Patricia, Sexton, Mary J.·2000·American Journal of Roentgenology

Abstract

OBJECTIVE: We sought to evaluate the use of the Breast Imaging Reporting and Data System (BI-RADS) standardized mammography lexicon among and within observers and to distinguish variability in feature analysis from variability in lesion management. MATERIALS AND METHODS: Five experienced mammographers, not specifically trained in BI-RADS, used the lexicon to describe and assess 103 screening mammograms, including 30 (29%) showing cancer, and a subset of 86 mammograms with diagnostic evaluation, including 23 (27%) showing cancer. A subset of 13 screening mammograms (two with malignant findings, 11 with diagnostic evaluation) were rereviewed by each observer 2 months later. Kappa statistics were calculated as measures of agreement beyond chance. RESULTS: After diagnostic evaluation, the interobserver kappa values for describing features were as follows: breast density, 0.43; lesion type, 0.75; mass borders, 0.40; special cases, 0.56; mass density, 0.40; mass shape, 0.28; microcalcification morphology, 0.36; and microcalcification distribution, 0.47. Lesion management was highly variable, with a kappa value for final assessment of 0.37. When we grouped assessments recommending immediate additional evaluation and biopsy (BI-RADS categories 0, 4, and 5 combined) versus follow-up (categories 1, 2, and 3 combined), five observers agreed on management for only 47 (55%) of 86 lesions. Intraobserver agreement on management (additional evaluation or biopsy versus follow-up) was seen in 47 (85%) of 55 interpretations, with a kappa value of 0.35-1.0 (mean, 0.60) for final assessment. CONCLUSION: Inter- and intraobserver variability in mammographic interpretation is substantial for both feature analysis and management. Continued development of methods to improve standardization in mammographic interpretation is needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.174.6.1741769

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 1,273

Metadata

Authors
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J.
Venue
American Journal of Roentgenology
Published
2000-06
Volume
174
Issue
6
Pages
1769-1777
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1860760959
Cited by
1,273
References
1
FWCI
26.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Breast Imaging Reporting and Data System: Inter- and Intraobserver Variability in Feature Analysis and Final Assessment. https://app.cochat.ai/papers/10.2214/ajr.174.6.1741769
The paper
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J. (2000). Breast Imaging Reporting and Data System: Inter- and Intraobserver Variability in Feature Analysis and Final Assessment. American Journal of Roentgenology. https://doi.org/10.2214/ajr.174.6.1741769

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.