The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
A 7 Minute Neurocognitive Screening Battery Highly Sensitive to Alzheimer's Disease
Abstract
OBJECTIVE: To determine the validity and reliability of a rapidly administered neurocognitive screening battery consisting of 4 brief tests (Enhanced Cued Recall, Temporal Orientation, Verbal Fluency, and Clock Drawing) to distinguish between patients with probable Alzheimer's disease (AD) and healthy control subjects. SUBJECTS: Sixty successive referrals to the Memory Disorders Clinic at Southwestern Vermont Medical Center, Bennington, who were diagnosed as having probable AD and 60 community-dwelling volunteers of comparable age, sex distribution, and education. DESIGN: Interrater and test-retest reliability, intergroup comparisons between patients with AD and control subjects on the 4 individual tests, and determination of probability of dementia for patients with AD and control subjects using the entire battery of tests. SETTING: Outpatient care. MAIN OUTCOME MEASURE: Comparison of the probability of dementia on the 7 Minute Screen with the criterion standard of clinical diagnosis established by examination and laboratory studies. SECONDARY OUTCOME MEASURES: Test-retest and interrater reliability (correlation coefficients), time for administration. RESULTS: Mean time of administration was 7 minutes 42 seconds. Mean scores for patients with AD and control subjects on all 4 individual tests were significantly different (for each, P<.001). When the 4 tests were combined in a logistic regression, the battery had a sensitivity of 100% and a specificity of 100%. A series of 1000 repeated random samples of 30 patients with AD and 30 control subjects taken from the overall sample of 60 patients with AD and 60 control subjects had a mean sensitivity of 92% and a mean specificity of 96%. The battery was equally sensitive to patients with mild AD as demonstrated by correctly classifying all 13 patients with AD using Mini-Mental State Examination scores of 24 or higher. Neither age nor education was a statistically significant factor when added as a covariate. Test-retest reliabilities for individual tests ranged from 0.83 to 0.93. Test-retest reliability for the entire battery was 0.91. Interrater reliability for the entire battery was 0.92. CONCLUSIONS: The 7 Minute Screen appears highly sensitive to AD and may be useful in helping to make initial distinctions between patients experiencing cognitive changes related to the normal aging process and those experiencing cognitive deficits related to dementing disorders such as AD. It has reasonable interrater and test-retest reliability, can be administered in a brief period, and requires no clinical judgment and minimal training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Folstein, M. F., Folstein, S. E., & McHugh, P. R. (1975) · Journal of Psychiatric Research · doi:10.1016/0022-3956(75)90026-6 · Cited by 88,282
McKhann, G., Drachman, D., Folstein, M., Katzman, R., Price, D., & Stadlan, E. M. (1984) · Neurology · doi:10.1212/wnl.34.7.939 · Cited by 27,915
The Mini‐Mental State Examination: A Comprehensive Review
Tombaugh, T. N., & McIntyre, N. J. (1992) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1992.tb01992.x · Cited by 5,152
A new rating scale for Alzheimer's disease
(1984) · American Journal of Psychiatry · doi:10.1176/ajp.141.11.1356 · Cited by 4,175
Blessed, G., Tomlinson, B. E., & Roth, M. (1968) · British Journal of Psychiatry · doi:10.1192/bjp.114.512.797 · Cited by 4,117
Evans, D. A. (1989) · JAMA · doi:10.1001/jama.262.18.2551 · Cited by 1,626
Contributions to Neuropsychological Assessment
Sarazin, F. (1996) · Europe PMC (PubMed Central) · Cited by 1,151
Anthony, J. C., LeResche, L., Niaz, U., Von Korff, M. R., & Folstein, M. F. (1982) · Psychological Medicine · doi:10.1017/s0033291700046730 · Cited by 1,110
Genuine memory deficits in dementia
Grober, E., & Buschke, H. (1987) · Developmental Neuropsychology · doi:10.1080/87565648709540361 · Cited by 1,047
Clock Drawing in Alzheimer's Disease: A Novel Measure of Dementia Severity
Sunderland, T., Hill, J. L., Mellow, A. M., Lawlor, B. A., Gundersheimer, J., Newhouse, P. A., & Grafman, J. H. (1989) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1989.tb02233.x · Cited by 1,029
Cited by
The Montreal Cognitive Assessment, MoCA: a brief screening tool for mild cognitive impairment
Nasreddine, Z. S., Phillips, N. A., Bédirian, V., Charbonneau, S., Whitehead, V., Collin, I., Cummings, J. L., & Chertkow, H. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53221.x · Cited by 25,553
Petersen, R. C., Stevens, J. C., Ganguli, M., Tangalos, E. G., Cummings, J. L., & DeKosky, S. T. (2001) · Neurology · doi:10.1212/wnl.56.9.1133 · Cited by 2,065
Six-item screener to identify cognitive impairment among potential subjects for clinical research
Callahan, C. M., Unverzagt, F. W., Hui, S. L., Perkins, A. J., & Hendrie, H. C. (2002) · Medical Care · doi:10.1097/00005650-200209000-00007 · Cited by 1,499
Clock-drawing: is it the ideal cognitive screening test?
Shulman, K. I. (2000) · International Journal of Geriatric Psychiatry · doi:10.1002/1099-1166(200006)15:6<548::aid-gps242>3.0.co;2-u · Cited by 1,361
Petersen, R. C. (2016) · Continuum · doi:10.1212/con.0000000000000313 · Cited by 909
Metadata
- Authors
- Solomon, P. R., Hirschoff, A., Kelly, B., Relin, M., Brush, M., DeVeaux, R. D., & Pendlebury, W. W.
- Venue
- Archives of Neurology
- Publisher
- American Medical Association (AMA)
- Published
- 1998-03-01
- Volume
- 55
- Issue
- 3
- Pages
- 349
- ISSN
- 0003-9942 (ISSN-L)
- OpenAlex
- W2014598951
- Cited by
- 418
- References
- 36
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 7 Minute Neurocognitive Screening Battery Highly Sensitive to Alzheimer's Disease. https://app.cochat.ai/papers/10.1001/archneur.55.3.349
- The paper
- Solomon, P. R., Hirschoff, A., Kelly, B., Relin, M., Brush, M., DeVeaux, R. D., & Pendlebury, W. W. (1998). A 7 Minute Neurocognitive Screening Battery Highly Sensitive to Alzheimer's Disease. Archives of Neurology. https://doi.org/10.1001/archneur.55.3.349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.