Enhanced Visualization of Macular Pathology With the Use of Ultrahigh-Resolution Optical Coherence Tomography
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To demonstrate a new generation of ophthalmic optical coherence tomography (OCT) technology with unprecedented axial resolution for enhanced imaging of intraretinal microstructures and to investigate its clinical feasibility to visualize intraretinal morphology of macular pathology. METHODS: A clinically viable ultrahigh-resolution ophthalmic OCT system was developed and used in clinical imaging for the first time. Fifty-six eyes of 40 selected patients with different macular diseases including macular hole, macular edema, age-related macular degeneration, central serous chorioretinopathy, epiretinal membranes, and detachment of pigment epithelium and sensory retina were included. OUTCOME MEASURES: Ultrahigh-resolution tomograms visualizing intraretinal morphologic features in different retinal diseases. RESULTS: An axial image resolution of approximately 3 micro m was achieved in the eyes examined, nearly 2 orders of magnitude better than conventional ophthalmic ultrasound. Ultrahigh-resolution OCT images provided additional diagnostically important information on intraretinal morphologic features that could not have been obtained by standard techniques. CONCLUSIONS: Ultrahigh-resolution ophthalmic OCT enables unprecedented visualization of intraretinal morphologic features and therefore has the potential to contribute to a better understanding of ocular pathogenesis, as well as to enhance the sensitivity and specificity for early ophthalmic diagnosis and to monitor the efficacy of therapy. This study establishes a baseline for the interpretation of ultrahigh-resolution ophthalmic OCT imaging of macular diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Self-citationMorphometric analysis of Bruch's membrane, the choriocapillaris, and the choroid in aging.
Ramrattan, R. S., van der Schaft, T. L., Mooy, C. M., de Bruijn, W. C., Mulder, P. G. H., & de Jong, P. T. (1994) · PubMed · Cited by 906
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Optical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Fercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
Johnson, R. N., & Gass, J. D. M. (1988) · Ophthalmology · doi:10.1016/s0161-6420(88)33075-7 · Cited by 408
Takada, K., Yokohama, I., Chida, K., & Noda, J. (1987) · Applied Optics · doi:10.1364/ao.26.001603 · Cited by 371
Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function.
Bowd, C., Zangwill, L. M., Berry, C. C., Blumenthal, E. Z., Vasile, C., Sánchez-Galeana, C. A., Bosworth, C. F., Sample, P. A., & Weinreb, R. N. (2001) · PubMed · Cited by 369
Retinal thickness study with optical coherence tomography in patients with diabetes.
Sánchez-Tocino, H., Alvárez-Vidal, A., Maldonado, M. J., Moreno‐Montañés, J., & García‐Layana, A. (2002) · PubMed · Cited by 251
Gloesmann, M., Hermann, B., Schubert, C., Sattmann, H., Ahnelt, P. K., & Drexler, W. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0654 · Cited by 226
Self-citationOphthalmic Laser Interferometry
Fercher, A. F., & Roth, E. (1986) · SPIE Proceedings · doi:10.1117/12.938523 · Cited by 159
Sidman, R. L. (1957) · The Journal of Cell Biology · doi:10.1083/jcb.3.1.15 · Cited by 156
Papillofoveal Traction in Macular Hole Formation
Chauhan, D. S. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.32 · Cited by 131
Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system.
Muscat, S., Parks, S., Kemp, E., & Keating, D. (2002) · PubMed · Cited by 119
Pons, M. E. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.8.1044 · Cited by 63
Cited by
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Wojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationStaurenghi, G., Sadda, S., Chakravarthy, U., & Spaide, R. F. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.02.023 · Cited by 861
Spaide, R. F., & Curcio, C. A. (2011) · Retina · doi:10.1097/iae.0b013e3182247535 · Cited by 723
Metadata
- Authors
- Drexler, W.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2003-05-01
- Volume
- 121
- Issue
- 5
- Pages
- 695
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2104231843
- Cited by
- 467
- References
- 16
- FWCI
- 26.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.