Enhanced Visualization of Macular Pathology With the Use of Ultrahigh-Resolution Optical Coherence Tomography
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To demonstrate a new generation of ophthalmic optical coherence tomography (OCT) technology with unprecedented axial resolution for enhanced imaging of intraretinal microstructures and to investigate its clinical feasibility to visualize intraretinal morphology of macular pathology. METHODS: A clinically viable ultrahigh-resolution ophthalmic OCT system was developed and used in clinical imaging for the first time. Fifty-six eyes of 40 selected patients with different macular diseases including macular hole, macular edema, age-related macular degeneration, central serous chorioretinopathy, epiretinal membranes, and detachment of pigment epithelium and sensory retina were included. OUTCOME MEASURES: Ultrahigh-resolution tomograms visualizing intraretinal morphologic features in different retinal diseases. RESULTS: An axial image resolution of approximately 3 micro m was achieved in the eyes examined, nearly 2 orders of magnitude better than conventional ophthalmic ultrasound. Ultrahigh-resolution OCT images provided additional diagnostically important information on intraretinal morphologic features that could not have been obtained by standard techniques. CONCLUSIONS: Ultrahigh-resolution ophthalmic OCT enables unprecedented visualization of intraretinal morphologic features and therefore has the potential to contribute to a better understanding of ocular pathogenesis, as well as to enhance the sensitivity and specificity for early ophthalmic diagnosis and to monitor the efficacy of therapy. This study establishes a baseline for the interpretation of ultrahigh-resolution ophthalmic OCT imaging of macular diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Self-citationMorphometric analysis of Bruch's membrane, the choriocapillaris, and the choroid in aging.
Ramrattan, R. S., van der Schaft, T. L., Mooy, C. M., de Bruijn, W. C., Mulder, P. G. H., & de Jong, P. T. (1994) · PubMed · Cited by 906
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Optical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Fercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
Johnson, R. N., & Gass, J. D. M. (1988) · Ophthalmology · doi:10.1016/s0161-6420(88)33075-7 · Cited by 408
Takada, K., Yokohama, I., Chida, K., & Noda, J. (1987) · Applied Optics · doi:10.1364/ao.26.001603 · Cited by 371
Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function.
Bowd, C., Zangwill, L. M., Berry, C. C., Blumenthal, E. Z., Vasile, C., Sánchez-Galeana, C. A., Bosworth, C. F., Sample, P. A., & Weinreb, R. N. (2001) · PubMed · Cited by 369
Retinal thickness study with optical coherence tomography in patients with diabetes.
Sánchez-Tocino, H., Alvárez-Vidal, A., Maldonado, M. J., Moreno‐Montañés, J., & García‐Layana, A. (2002) · PubMed · Cited by 251
Cited by
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Wojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationStaurenghi, G., Sadda, S., Chakravarthy, U., & Spaide, R. F. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.02.023 · Cited by 861
Spaide, R. F., & Curcio, C. A. (2011) · Retina · doi:10.1097/iae.0b013e3182247535 · Cited by 723
Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography
Wojtkowski, M., Srinivasan, V., Fujimoto, J. G., Ko, T., Schuman, J. S., Kowalczyk, A., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.023 · Cited by 640
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
Nassif, N., Cense, B., Hyle Park, B., Yun, S. H., Chen, T. C., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Letters · doi:10.1364/ol.29.000480 · Cited by 498
Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography
Cense, B., Nassif, N. A., Chen, T. C., Pierce, M. C., Yun, S.-H., Park, B. H., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Express · doi:10.1364/opex.12.002435 · Cited by 468
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Wolf-Schnurrbusch, U. E. K., Ceklic, L., Brinkmann, C. K., Iliev, M. E., Frey, M., Rothenbuehler, S. P., Enzmann, V., & Wolf, S. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2970 · Cited by 424
Hirata, M., Tsujikawa, A., Matsumoto, A., Hangai, M., Ooto, S., Yamashiro, K., Akiba, M., & Yoshimura, N. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7729 · Cited by 365
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Chen, T. C. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.12.1715 · Cited by 327
Srinivasan, V. J., Wojtkowski, M., Witkin, A. J., Duker, J. S., Ko, T. H., Carvalho, M., Schuman, J. S., Kowalczyk, A., & Fujimoto, J. G. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.046 · Cited by 317
Ophthalmic imaging by spectral optical coherence tomography
Wojtkowski, M., Bajraszewski, T., Gorczyńska, I., Targowski, P., Kowalczyk, A., Wasilewski, W., & Radzewicz, C. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.04.049 · Cited by 291
Fleckenstein, M., Issa, P. C., Helb, H.-M., Schmitz-Valckenberg, S., Finger, R. P., Scholl, H. P. N., Loeffler, K. U., & Holz, F. G. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-1967 · Cited by 283
Srinivasan, V. J., Monson, B. K., Wojtkowski, M., Bilonick, R. A., Gorczynska, I., Chen, R., Duker, J. S., Schuman, J. S., & Fujimoto, J. G. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0838 · Cited by 277
Three-Dimensional Ultrahigh-Resolution Optical Coherence Tomography of Macular Diseases
Schmidt-Erfurth, U. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0370 · Cited by 271
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Human Chorioretinal Layer Thicknesses Measured in Macula-wide, High-Resolution Histologic Sections
Curcio, C. A., Messinger, J. D., Sloan, K. R., Mitra, A., McGwin, G., & Spaide, R. F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6377 · Cited by 251
Kiernan, D. F., Mieler, W. F., & Hariprasad, S. M. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.08.037 · Cited by 246
“Since 2004, higheresolution spectral-domain OCT (SD OCT) has entered linical practice with reported resolutions of 1 to 5 m as ell as improved visualization of retinal morphologic and athologic features.(2) SD OCT technology uses low-coherence interferometry o detect light echoes, relying on a spectrometer and igh-spe…”
BackgroundRetinal assessment using optical coherence tomography
Costa, R. A., Skaf, M., Melo, L. A. S., Calucci, D., Cardillo, J. A., Castro, J. C., Huang, D., & Wojtkowski, M. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.03.001 · Cited by 232
“, 2005) and the University of Vienna (Drexler et al., 2003).”
BackgroundMethodResultInfluentialKo, T. H., Fujimoto, J. G., Schuman, J. S., Paunescu, L. A., Kowalevicz, A. M., Hartl, I., Drexler, W., Wollstein, G., Ishikawa, H., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.027 · Cited by 224
Self-citationCense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1160 · Cited by 221
“The difference between high-resolution optical coherence tomography (HR-OCT) and conventional OCT is that HR-OCT uses a light source with a particularly large optical bandwidth, allowing for RNFL thickness measurements with an accuracy of up to 3 m.(4) However, current ultrabroadband sources are expensive and complex,…”
BackgroundOphthalmic fundus imaging: today and beyond
Yannuzzi, L. A., Ober, M. D., Slakter, J. S., Spaide, R. F., Fisher, Y. L., Flower, R. W., & Rosen, R. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.12.035 · Cited by 207
TOMOGRAPHIC FEATURES OF BRANCHING VASCULAR NETWORKS IN POLYPOIDAL CHOROIDAL VASCULOPATHY
SATO, T., KISHI, S., WATANABE, G., MATSUMOTO, H., & MUKAI, R. (2007) · Retina · doi:10.1097/01.iae.0000249386.63482.05 · Cited by 206
Evaluation of image artifact produced by optical coherence tomography of retinal pathology
Ray, R., Stinnett, S. S., & Jaffe, G. J. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.07.050 · Cited by 202
Považay, B., Hermann, B., Unterhuber, A., Hofer, B., Sattmann, H., Zeiler, F., Morgan, J. E., Falkner-Radler, C., Glittenberg, C., Blinder, S., et al. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2773728 · Cited by 199
Self-citationEnhanced optical coherence tomography imaging by multiple scan averaging
Sander, B. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.045989 · Cited by 187
“Further improvements are possible with ultra high resolution instruments based on titanium sapphire lasers; however, this instrument is yet not commercially available.”
BackgroundKhanifar, A. A., Koreishi, A. F., Izatt, J. A., & Toth, C. A. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.04.041 · Cited by 184
“Whereas other high-resolution OCT devices may use a titanium-sapphire laser,(6) a superluminescent diode is more cost-efficient.(11,13) The power incident on a patient’s eye is 500 50 W, below the American National Standards Institute extended exposure limit of 700 W over 8 hours.”
BackgroundVisual function and dysfunction in early and late age-related maculopathy
Hogg, R. E., & Chakravarthy, U. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.11.002 · Cited by 182
“Recent improvements in retinal imaging, such as ultra-high-resolution optical coherence tomography (Drexler et al., 2003), multi-modal macular mapping (Bernardes et al.”
BackgroundLorenz, B., Wabbels, B., Wegscheider, E., Hamel, C. P., Drexler, W., & Preising, M. N. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.01.033 · Cited by 172
Self-citationIn vivo functional imaging of human cone photoreceptors
Jonnal, R. S., Rha, J., Zhang, Y., Cense, B., Gao, W., & Miller, D. T. (2007) · Optics Express · doi:10.1364/oe.15.016141 · Cited by 169
Human Macula Investigated In Vivo with Polarization-Sensitive Optical Coherence Tomography
Pircher, M., Go¨tzinger, E., Findl, O., Michels, S., Geitzenauer, W., Leydolt, C., Schmidt-Erfurth, U., & Hitzenberger, C. K. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1589 · Cited by 161
“Note that a clear separation between layers 3 and 4 is not always visible in intensity-based UHR-OCT images.(9,34) This unclear separation may be the reason for the controversy in labeling of layers 3 and 4 in the literature, in which the following layer associations are found: 1 is the external limiting membrane (ELM…”
Witkin, A. J., Ko, T. H., Fujimoto, J. G., Chan, A., Drexler, W., Schuman, J. S., Reichel, E., & Duker, J. S. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.07.024 · Cited by 161
Self-citationErgun, E., Hermann, B., Wirtitsch, M., Unterhuber, A., Ko, T. H., Sattmann, H., Scholda, C., Fujimoto, J. G., Stur, M., & Drexler, W. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0212 · Cited by 160
Self-citationOptical Coherence Tomography Use in Evaluation of the Vitreoretinal Interface: A Review
Mirza, R. G., Johnson, M. W., & Jampol, L. M. (2007) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2007.04.007 · Cited by 158
Metadata
- Authors
- Drexler, W.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2003-05-01
- Volume
- 121
- Issue
- 5
- Pages
- 695
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2104231843
- Cited by
- 467
- References
- 16
- FWCI
- 26.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.