CoChat

Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants

Greenes, David S., Fleisher, Gary R. · 2001 · Archives of Pediatrics & Adolescent Medicine
Cited by 140

The DOI matches its Crossref record.

Abstract

OBJECTIVES: To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN: Prospective evaluation of the accuracy of TA and tympanic thermometry, using rectal thermometry as the criterion standard. SETTING: Emergency department of an urban pediatric hospital. SUBJECTS: Convenience sample of 304 infants younger than 1 year presenting for care. MAIN OUTCOME MEASURES: Temperatures were measured using TA, tympanic, and rectal thermometers for all infants. Agreement between TA or tympanic and rectal temperatures was assessed. The sensitivity and specificity of TA or tympanic thermometers for detecting rectal fever were determined. Discomfort scores, using a standardized scale, were assessed by trained observers after each temperature measurement was made. RESULTS: Linear regression analysis of the relation between TA and rectal temperatures yielded a model with a slope of 0.79 (vs a slope of 0.68 for tympanic vs rectal temperature; P =.02) and an r of 0.83 (vs r = 0.75 for tympanic vs rectal temperature; P<.001). Among 109 patients with a rectal temperature of 38 degrees C or higher, the TA thermometer had a sensitivity of 0.66 compared with the tympanic thermometer's sensitivity of 0.49 (P<.001). Discomfort scores with TA thermometry were significantly lower than with rectal thermometry (P =.007). CONCLUSIONS: The TA thermometer has limited sensitivity for detecting cases of rectal fever in infants. However, the TA thermometer is more accurate than the tympanic thermometer in infants, and it is better tolerated by infants than rectal thermometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archpedi.155.3.376

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Greenes, D. S., & Fleisher, G. R.
Venue
Archives of Pediatrics & Adolescent Medicine
Published
2001-03-01
Volume
155
Issue
3
Pages
376
ISSN
1072-4710 (ISSN-L)
OpenAlex
W2013328075
Cited by
140
References
0
FWCI
4.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants. https://app.cochat.ai/papers/10.1001/archpedi.155.3.376
The paper
Greenes, D. S., & Fleisher, G. R. (2001). Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants. Archives of Pediatrics & Adolescent Medicine. https://doi.org/10.1001/archpedi.155.3.376

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.