Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record.

Comparison of a New Fibrin Sealant With Standard Topical Hemostatic Agents

Schwartz, Myron·2004·Archives of Surgery

Abstract

BACKGROUND: Bleeding following liver resection continues to be a significant morbidity of the procedure. Fibrin sealants represent an improvement over conventional topical hemostatic agents, because they contain components that actively form clot. However, most available agents contain nonhuman protein, which represents an immunologic risk. HYPOTHESIS: An investigational surgical fibrin sealant (Crosseal; American Red Cross, Washington, DC) composed of human clottable proteins and human thrombin is more effective than standard topical hemostatic agents in reducing the time required to achieve hemostasis after liver resection. DESIGN: Prospective, randomized, controlled trial. SETTING: Fifteen major referral centers in the United States and the United Kingdom. METHODS: After liver resection using standard surgical techniques, 121 patients seen between May 1999 and May 2000 were randomized to treatment with a 2-component fibrin sealant (n=58) or to standard topical hemostatic agents, used singly or in combination (n=63). Up to 10 mL of Crosseal was administered by a spray applicator, as recommended by the manufacturer, whereas agents used in the control group were applied according to their instructions for use. MAIN OUTCOME MEASURES: The primary outcome measured was time to hemostasis. Secondary outcomes measured included blood loss between application of the hemostatic agent and closure of the abdomen, duration of postoperative biliary drainage, and the occurrence of complications, defined a priori as reoperation for any reason, development of abdominal fluid collections, or bilious appearance of drained fluid for at least 1 day postoperatively. RESULTS: The mean time to hemostasis was 282 seconds with Crosseal, compared with 468 seconds with standard agents (2-sided; P =.06), for the 116 efficacy-evaluable patients. Hemostasis was achieved within 10 minutes in 53 patients (91.4%) treated with the study fibrin sealant and in 44 control patients (69.8%) (2-sided; P =.003). Intraoperative blood loss was similar in the 2 groups. In the Crosseal group, the percentage of patients developing postoperative complications was 17.2%, compared with 36.5% in the control group (2-sided; P =.02). CONCLUSIONS: Compared with the use of standard topical hemostatic agents, Crosseal fibrin sealant significantly reduced the time to achieve hemostasis following liver resection. Patients treated with the new fibrin sealant also experienced significantly fewer postoperative complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archsurg.139.11.1148

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Schwartz, M.
Venue
Archives of Surgery
Published
2004-11-01
Volume
139
Issue
11
Pages
1148
ISSN
0004-0010 (ISSN-L)
OpenAlex
W2116821301
Cited by
160
References
0
FWCI
2.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of a New Fibrin Sealant With Standard Topical Hemostatic Agents. https://app.cochat.ai/papers/10.1001/archsurg.139.11.1148
The paper
Schwartz, M. (2004). Comparison of a New Fibrin Sealant With Standard Topical Hemostatic Agents. Archives of Surgery. https://doi.org/10.1001/archsurg.139.11.1148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.