Matched Elastic Properties and Successful Arterial Grafting
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Clinical results from medium- and small-caliber arterial bypass grafts are unsatisfactory. Since elastic properties of grafts tested experimentally have been correlated with patency results, the compliance of the human femoral artery was compared with grafts currently in use: human saphenous vein (HSV), knitted Dacron (DAC), glutaraldehyde-treated umbilical cord vein (DBM), bovine heterograft, and expanded polytetrafluoroethylene (PTFE). This was correlated with clinical patency data for the different conduits in the femoropopliteal position. Increased patency correlated with a decreasing disparity between host artery and graft compliance. After two years, patency rates of the more compliant materials (HSV, DBM) exceeded 80%, while less than 45% of the incompliant grafts (DAC, PTFE) remained patent. Thus, clinical performance with synthetic grafts might be improved by use of prostheses in which the viscoelastic characteristics match those of arteries more closely.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
Compliance as a factor effecting the patency of a copolyurethane vascular graft
Lyman, D. J., Fazzio, F. J., Voorhees, H., Robinson, G., & Albo, D. (1978) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820120307 · Cited by 94
Dynamic compliance of arterial grafts
Baird, R. N., Kidson, I. G., L'Italien, G. J., et al. (1977) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1977.233.5.h568 · Cited by 81
Consideration of suture line stresses in the selection of synthetic grafts for implantation
Paasche, P. E., Kinley, C. E., Dolan, F. G., GOZNA, E. R., & Marble, A. E. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90047-x · Cited by 53
Cited by
Effect of compliance mismatch on vascular graft patency
Abbott, W. M., Megerman, J., Hasson, J. E., L'Italien, G., & Warnock, D. F. (1987) · Journal of Vascular Surgery · doi:10.1016/0741-5214(87)90148-0 · Cited by 484
Anastomotic intimal hyperplasia: Mechanical injury or flow induced
Bassiouny, H. S., White, S., Glagov, S., Choi, E., Giddens, D. P., & Zarins, C. K. (1992) · Journal of Vascular Surgery · doi:10.1016/0741-5214(92)90019-5 · Cited by 426
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Camasão, D. B., & Mantovani, D. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100106 · Cited by 310
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.01.006 · Cited by 301
Compliance mismatch may promote graft–artery intimal hyperplasia by altering suture-line stresses
Ballyk, P. D., Walsh, C., Butany, J., & Ojha, M. (1997) · Journal of Biomechanics · doi:10.1016/s0197-3975(97)00111-5 · Cited by 272
Puskas, J. E., & Chen, Y. (2004) · Biomacromolecules · doi:10.1021/bm034513k · Cited by 269
Compliance properties of conduits used in vascular reconstruction
Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01566.x · Cited by 267
Development and evaluation of a novel decellularized vascular xenograft
Conklin, B. S., Richter, E. R., Kreutziger, K. L., Zhong, D.-S., & Chen, C. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00010-3 · Cited by 254
Small Intestinal Submucosa as a Vascular Graft: A Review
Lantz, G. C., Badylak, S. F., Hiles, M. C., Coffey, A. C., Geddes, L. A., Kokini, K., Sandusky, G. E., & Morff, R. J. (1993) · Journal of Investigative Surgery · doi:10.3109/08941939309141619 · Cited by 249
Polytetrafluoroethylene Graft Survival in Hemodialysis
Munda, R. (1983) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1983.03330260037028 · Cited by 210
Biodegradable polyester elastomers in tissue engineering
Webb, A. R., Yang, J., & Ameer, G. A. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.6.801 · Cited by 208
“Furthermore, as vascular graft and tissue engineering scaffold materials are rigid, the development of elastomeric scaffolds may alleviate the problem of compliance mismatch between a vascular graft and a host vessel, a problem that has been linked to incomplete endothelialisation and myointimal hyperplasia at the ana…”
BackgroundMedical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries
Singh, C., Wong, C., & Wang, X. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6030500 · Cited by 196
“Adapted from [115]; PTFE, Polytetrafluoroethylene.”
Inoguchi, H., Kwon, I. K., Inoue, E., Takamizawa, K., Maehara, Y., & Matsuda, T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.08.029 · Cited by 166
Effect of Healing on Small Internal Diameter Arterial Graft Compliance
White, R., Goldberg, L., Hirose, F., Klein, S., Bosco, P., Miranda, R., Long, J., Nelson, R., & Shors, E. (1983) · Biomaterials, Medical Devices, and Artificial Organs · doi:10.3109/10731198309118791 · Cited by 38
Metadata
- Authors
- Walden, R.
- Venue
- Archives of Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 1980-10-01
- Volume
- 115
- Issue
- 10
- Pages
- 1166
- ISSN
- 0004-0010 (ISSN-L)
- OpenAlex
- W2114604286
- Cited by
- 234
- References
- 4
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.