The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Open accessAbstract
When autologous vein is unavailable, prosthetic graft materials, particularly expanded polytetrafluoroethylene are used for peripheral arterial revascularisation. Poor long term patency of prosthetic materials is due to distal anastomotic intimal hyperplasia. Intimal hyperplasia is directly linked to shear stress abnormalities at the vessel wall. Compliance and calibre mismatch between native vessel and graft, as well as anastomotic line stress concentration contribute towards unnatural wall shear stress. High porosity reduces graft compliance by causing fibrovascular infiltration, whereas low porosity discourages the development of an endothelial lining and hence effective antithrombogenicity. Therefore, consideration of mechanical properties is necessary in graft development. Current research into synthetic vascular grafts concentrates on simulating the mechanical properties of native arteries and tissue engineering aims to construct a new biological arterial conduit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Saphenous Vein Versus PTFE for Above-Knee Femoropopliteal Bypass. A Review of the Literature
Klinkert, P., Post, P. N., Breslau, P. J., & van Bockel, J. H. (2004) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2003.12.027 · Cited by 520
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Self-citationTissue engineering of small caliber vascular grafts
Hoerstrup, S. (2001) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(01)00706-0 · Cited by 281
Compliance properties of conduits used in vascular reconstruction
Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01566.x · Cited by 267
Self-citationMorphologic and mechanical characteristics of engineered bovine arteries
Niklason, L. E., Abbott, W., Gao, J., Klagges, B., Hirschi, K. K., Ulubayram, K., Conroy, N., Jones, R., Vasanawala, A., Sanzgiri, S., et al. (2001) · Journal of Vascular Surgery · doi:10.1067/mva.2001.111747 · Cited by 254
Bank, A. J., Wang, H., Holte, J. E., Mullen, K., Shammas, R., & Kubo, S. H. (1996) · Circulation · doi:10.1161/01.cir.94.12.3263 · Cited by 248
Matched Elastic Properties and Successful Arterial Grafting
Walden, R. (1980) · Archives of Surgery · doi:10.1001/archsurg.1980.01380100018004 · Cited by 234
Porosity: primary determinant of ultimate fate of synthetic vascular grafts.
WESOLOWSKI, S. A., Cc, F., Karlson, K. E., et al. (1961) · PubMed · Cited by 210
Cited by
Tissue engineering by self-assembly and bio-printing of living cells
Jakab, K., Norotte, C., Marga, F., Murphy, K., Vunjak-Novakovic, G., & Forgacs, G. (2010) · Biofabrication · doi:10.1088/1758-5082/2/2/022001 · Cited by 593
Chlupáč, J., Filová, E., & Bačáková, L. (2009) · Physiological Research · doi:10.33549/physiolres.931918 · Cited by 408
Stem cell sources for vascular tissue engineering and regeneration
Bajpai, V. K., & Andreadis, S. T. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0264 · Cited by 95
Wang, Y., Chen, S., Pan, Y., Gao, J., Tang, D., Kong, D., & Wang, S. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb02080h · Cited by 50
Park, A. R., Park, Y.-H., Kim, H. J., Kim, M.-K., Kim, S.-G., Kweon, H., & Kundu, S. C. (2015) · Macromolecular Research · doi:10.1007/s13233-015-3126-x · Cited by 20
Metadata
- Authors
- Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M.
- Venue
- European Journal of Vascular and Endovascular Surgery
- Publisher
- Elsevier BV
- Published
- 2006-06
- Volume
- 31
- Issue
- 6
- Pages
- 627-636
- ISSN
- 1078-5884 (ISSN-L)
- OpenAlex
- W2059138360
- Cited by
- 301
- References
- 38
- FWCI
- 10.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency. https://app.cochat.ai/papers/10.1016/j.ejvs.2006.01.006
- The paper
- Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006). The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2006.01.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.