Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Airborne transmission of infectious agents and associations of indoor air pollutants with respiratory illnesses are well documented. We hypothesized that energy conservation measures that tighten buildings also increase risks of respiratory infection among building occupants. At four Army training centers during a 47-month period, incidence rates of febrile acute respiratory disease were compared between basic trainees in modern (energy-efficient design and construction) and old barracks. Rates of febrile acute respiratory disease were significantly higher among trainees in modern barracks (adjusted relative risk estimate, 1.51; 95% confidence interval, 1.46 to 1.56), and relative risks were consistent at the four centers. These results support the hypothesis that tight buildings with closed ventilation systems significantly increase risks of respiratory-transmitted infection among congregated, immunologically susceptible occupants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932
Epidemiology of community-acquired respiratory tract infections in adults
Garibaldi, R. A. (1985) · The American Journal of Medicine · doi:10.1016/0002-9343(85)90361-4 · Cited by 393
Interpandemic Influenza in the Houston Area, 1974–76
Glezen, W. P., Couch, R. B., MacLean, R. A., Payne, A., Baird, J. N., Vallbona, C., Tristan, M., & Byrd, N. (1978) · New England Journal of Medicine · doi:10.1056/nejm197803162981103 · Cited by 386
Impact of influenza epidemics on mortality in the United States from October 1972 to May 1985.
Lui, K. J., & Kendal, A. P. (1987) · American Journal of Public Health · doi:10.2105/ajph.77.6.712 · Cited by 319
Riley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Aerosol transmission of rhinovirus colds
Dick, E. C., Jennings, L. C., Mink, K. A., Wartgow, C. D., & Inborn, S. L. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.3.442 · Cited by 280
Airborne Transmission of Chickenpox in a Hospital
Leclair, J. M., Zaia, J. A., Levin, M. J., Congdon, R. G., & Goldmann, D. A. (1980) · New England Journal of Medicine · doi:10.1056/nejm198002213020807 · Cited by 263
Measles Outbreak in a Pediatric Practice: Airborne Transmission in an Office Setting
Bloch, A. B., Orenstein, W. A., Ewing, W. M., Spain, W. H., Mallison, G. F., Herrmann, K. L., & Hinman, A. R. (1985) · Pediatrics · doi:10.1542/peds.75.4.676 · Cited by 237
Couch, R. B., Cate, T. R., Douglas, R. G., Gerone, P. J., & Knight, V (1966) · Bacteriological Reviews · doi:10.1128/br.30.3.517-529.1966 · Cited by 221
The Epidemiology of Tuberculosis Infection in a Closed Environment
Houk, V. N., Baker, J. H., Sorensen, K., & Kent, D. C. (1968) · Archives of Environmental Health: An International Journal · doi:10.1080/00039896.1968.10665011 · Cited by 190
Cited by
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
“One paper from the United States compared the prevalence of respiratory illness, during a 47-month period, among army trainees living in barracks (Brundage et al., 1988).”
BackgroundAdverse health effects of outdoor air pollutants
Curtis, L., Rea, W., Smith-Willis, P., Fenyves, E., & Pan, Y. (2006) · Environment International · doi:10.1016/j.envint.2006.03.012 · Cited by 579
Fisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Mendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 299
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
The relationships between classroom air quality and children’s performance in school
Wargocki, P., Porras-Salazar, J. A., Contreras-Espinoza, S., & Bahnfleth, W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106749 · Cited by 263
Mendell, M. J., & Smith, A. H. (1990) · American Journal of Public Health · doi:10.2105/ajph.80.10.1193 · Cited by 258
Summary of human responses to ventilation
Seppanen, O. A., & Fisk, W. J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00279.x · Cited by 249
“,1994, Brundage et al., 1988, Drinka et al., 1996, Milton et al., 2000). Even though the ventilation rates were estimated and not measured, the consistent findings are a strong indication of the association of ventilation rates with health effects. The strongest evidence is provided by the most recent study of these (…”
InfluentialMendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
Airborne particle sizes and sources found in indoor air
Owen, M. K., Ensor, D. S., & Sparks, L. E. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90403-8 · Cited by 214
I NDOOR A IR Q UALITY F ACTORS IN D ESIGNING A H EALTHY B UILDING
Spengler, J. D., & Chen, Q. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.567 · Cited by 194
“Tools for Designing Ventilation Increased awareness of the potential health risks associated with indoor air pollutants (68, 69, 70) has stimulated interest in improving our understanding of how ventilation air is distributed and how pollutants are transported in buildings.”
BackgroundRyan, M. A. K., Christian, R. S., & Wohlrabe, J. (2001) · American Journal of Preventive Medicine · doi:10.1016/s0749-3797(01)00323-3 · Cited by 182
“Specific initiatives included: (1) directive from the commanding officer that recruits would wash hands at least 5 times daily; (2) directive from the commanding officer that “wet sinks” would be allowed to pass inspection (prior to this direction, recruit handwashing sinks were kept clean and dry in order to pass spo…”
BackgroundTotal Concentrations of Virus and Bacteria in Indoor and Outdoor Air
Prussin, A. J., Garcia, E. B., & Marr, L. C. (2015) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.5b00050 · Cited by 181
Menzies, D., & Bourbeau, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711203372107 · Cited by 167
Prevention of hospital-acquired infections: review of non-pharmacological interventions
Curtis, L. T. (2008) · Journal of Hospital Infection · doi:10.1016/j.jhin.2008.03.018 · Cited by 164
“A study with army recruits reported significantly higher rates of acute respiratory disease when housed in poorly ventilated barracks compared with well-ventilated barracks.(154) The American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) has proposed standards of at least four outdoor air…”
BackgroundMumps outbreak in a highly vaccinated population
Hersh, B. S., Fine, P. E. M., Kent, W. K., Cochi, S. L., Kahn, L. H., Zell, E. R., Hays, P. L., & Wood, C. L. (1991) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)80726-7 · Cited by 160
Report of an outbreak: nursing home architecture and influenza-A attack rates
Drinka, P. J., Krause, P., Schilling, M., Miller, B. A., Shult, P., & Gravenstein, S. (1996) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1996.tb01859.x · Cited by 77
“Skilled Nursing Facility 105 (57) 280 (55) Intermediate Care Facility 1 66 (36) 169 (33) Intermediate Care Facility 2 9 (5) 31 (6) Intermediate Care Facility 3, 4 4 (2) 26 (5) Total 184 (100) 506 (100)”
Some Quantitative Relations between Indoor Environmental Quality and Work Performance or Health
Seppänen, O. A., & Fisk, W. (2006) · HVAC&R Research · doi:10.1080/10789669.2006.10391446 · Cited by 53
Metadata
- Authors
- Brundage, J. F.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1988-04-08
- Volume
- 259
- Issue
- 14
- Pages
- 2108
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2030999457
- Cited by
- 158
- References
- 24
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.