Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 432

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Does This Patient Have Delirium?: Value of Bedside Instruments

Wong, Camilla L., Holroyd-Leduc, Jayna, Simel, David L., Straus, Sharon E.·2010·JAMA

Abstract

CONTEXT: Delirium occurs in many hospitalized older patients and has serious consequences including increased risk for death and admission to long-term care. Despite its importance, health care clinicians often fail to recognize delirium. Simple bedside instruments may lead to improved identification. OBJECTIVE: To systematically review the evidence on the accuracy of bedside instruments in diagnosing the presence of delirium in adults. DATA SOURCES: Search of MEDLINE (from 1950 to May 2010), EMBASE (from 1980 to May 2010), and references of retrieved articles to identify studies of delirium among inpatients. STUDY SELECTION: Prospective studies of diagnostic accuracy that compared at least 1 delirium bedside instrument to the Diagnostic and Statistical Manual of Mental Disorders-based diagnosis made by a geriatrician, psychiatrist, or neurologist. DATA SYNTHESIS: There were 6570 unique citations identified with 25 prospectively conducted studies (N = 3027 patients) meeting inclusion criteria and describing use of 11 instruments. Positive results that suggested delirium with likelihood ratios (LRs) greater than 5.0 were present for the Global Attentiveness Rating (GAR), Memorial Delirium Assessment Scale (MDAS), Confusion Assessment Method (CAM), Delirium Rating Scale Revised-98 (DRS-R-98), Clinical Assessment of Confusion (CAC), and Delirium Observation Screening Scale (DOSS). Normal results that decreased the likelihood of delirium with LRs less than 0.2 were calculated for the GAR, MDAS, CAM, DRS-R-98, Delirium Rating Scale (DRS), DOSS, Nursing Delirium Screening Scale (Nu-DESC), and Mini-Mental State Examination (MMSE). The Digit Span test and Vigilance "A" test in isolation have limited utility in diagnosing delirium. Considering the instrument's ease of use, test performance, and clinical importance of the heterogeneity in the confidence intervals (CIs) of the LRs, the CAM has the best available supportive data as a bedside delirium instrument (summary-positive LR, 9.6; 95% CI, 5.8-16.0; summary-negative LR, 0.16; 95% CI, 0.09-0.29). Of all scales, the MMSE (score <24) was the least useful for identifying a patient with delirium (LR, 1.6; 95% CI, 1.2-2.0). CONCLUSION: The choice of instrument may be dictated by the amount of time available and the discipline of the examiner; however, the best evidence supports use of the CAM, which takes 5 minutes to administer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2010.1182

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 432

Metadata

Authors
Wong, C. L., Holroyd-Leduc, J., Simel, D. L., & Straus, S. E.
Venue
JAMA
Published
2010-08-18
Volume
304
Issue
7
Pages
779
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2159927428
Cited by
432
References
54
FWCI
23.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Does This Patient Have Delirium?: Value of Bedside Instruments. https://app.cochat.ai/papers/10.1001/jama.2010.1182
The paper
Wong, C. L., Holroyd-Leduc, J., Simel, D. L., & Straus, S. E. (2010). Does This Patient Have Delirium?: Value of Bedside Instruments. JAMA. https://doi.org/10.1001/jama.2010.1182

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.